(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
[Features]· Universal AC input / Full range· Installed on DIN rail TS35 / 7.5 or 15· Protections: Short circuit / Overload / Overvoltage· No load power consumption <0.75 W (<1 W for MDR-100)· LED indicator for power on· NEC class 2 / LPS compliant (selected models)· Built-in active PFC and over temp. protection (MDR-100)· DC OK signal output (MDR-10/20)· DC OK relay contact (MDR-40/60/100)· Cooling by free air convection· 100% full load burn-in test
Part Number |
---|
EDR-75-24 |
EDR-120-24 |
EDR-150-24 |
MDR-10-24 |
MDR-20-24 |
MDR-40-24 |
MDR-100-24 |
NDR-75-24 |
NDR-120-24 |
SDR-480-24 |
WDR-120-24 |
WDR-240-24 |
WDR-480-24 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Capacity (W) | Output voltage (Single only) | Rated output current (single only) (A) | Input/output terminal shape | Representative Standard | Dimension height (mm) | Dimension width (mm) | Dimension depth (mm) | Rated output current 1 for DC 24 V (A) | Rated output current 2 for DC 12 V (A) | Rated output current 3 for DC 5 V (A) | AC Input Voltage Range | AC Input current (Maximum) | DC adjustment range | Effi. | Overload protection | Over voltage protection | Withstand Voltage | Operating temperature | Safety Standard | EMC standards |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1,170,744 VND | 1 Piece(s) | 4 Day(s) | 75 | DC24V | 3.2 | - | UL / TUV | 32 | 125.2 | 102 | - | - | - | 90~264VAC; 127~370VDC | Cold start, 35A at 230VAC | 12V: 12~14V, 24V: 24~28V, 48V: 48~55V | 87.5% | 105%~130% Constant current limiting, auto-recovery | 12V: 14~17V, 24V: 29~33V, 48V: 56~65V Shut down o/p voltage, re-power on to recover | I/P-O/P: 3kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC | -20~+60°C (refer to output derating curve) | UL508, TUV EN60950-1 approved | EN55022 classA, EN61000-3-2(125W for EDR-150),3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(EN50082-2) | ||
1,500,499 VND | 1 Piece(s) | 7 Day(s) | 120 | DC24V | 5 | - | UL / TUV | 32 | 125.2 | 102 | - | - | - | 90~264VAC; 127~370VDC | Cold start, 35A at 230VAC | 12V: 12~14V, 24V: 24~28V, 48V: 48~55V | 87.5% | 105%~130% Constant current limiting, auto-recovery | 12V: 14~17V, 24V: 29~33V, 48V: 56~65V Shut down o/p voltage, re-power on to recover | I/P-O/P: 3kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC | -20~+60°C (refer to output derating curve) | UL508, TUV EN60950-1 approved | EN55022 classA, EN61000-3-2(125W for EDR-150),3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(EN50082-2) | ||
1,587,276 VND | 1 Piece(s) | 7 Day(s) | 150 | DC24V | 6.5 | - | UL / TUV | 40 | 125.2 | 113.5 | - | - | - | 90~264VAC; 127~370VDC | Cold start, 35A at 230VAC | 12V: 12~14V, 24V: 24~28V, 48V: 48~55V | 87% | 105%~130% Constant current limiting, auto-recovery | 24V: 29~33V Shut down o/p voltage, re-power on to recover | I/P-O/P: 3kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC | -20~+60°C (refer to output derating curve) | UL508, TUV EN60950-1 approved | EN55022 classA, EN61000-3-2(125W for EDR-150),3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(EN50082-2) | ||
701,370 VND | 1 Piece(s) | 4 Day(s) or more | 10 | DC24V | 0.42 | European format | CE / UL / CUL / TUV | 22.5 ~ 90 | 22.5 ~ 90 | 100 | 0.42 | - | - | 85~264VAC; 120~370VDC | Cold start, 35A at 115VAC, 70A at 230VAC | Fixed | 84% | >105% hiccup mode, auto-recovery | 115%~135% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -20~+70°C (refer to output derating curve) | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) | ||
797,012 VND | 1 Piece(s) | 4 Day(s) or more | 20 ~ 24 | DC24V | 1 | European format | CE / UL / CUL / TUV | 22.5 ~ 90 | 22.5 ~ 90 | 100 | 1 | - | - | 85~264VAC; 120~370VDC | Cold start, 20A at 115VAC, 40A at 230VAC | ±10% rated output voltage | 84% | 105%~160% constant current limiting, auto-recovery | 115%~135% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -20~+70°C (refer to output derating curve) | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) | ||
956,414 VND | 1 Piece(s) | 4 Day(s) or more | 40 ~ 40.8 | DC24V | 1.7 | European format | CE / UL / CUL / TUV | 40 ~ 90 | 40 ~ 90 | 100 | 1.7 | - | - | 85~264VAC; 120~370VDC | Cold start, 30A at 115VAC, 60A at 230VAC | 0~+20% rated output voltage | 88% | 105%~150% constant current limiting, auto-recovery | 125%~150% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -20~+70°C (refer to output derating curve) | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) | ||
1,689,666 VND | 1 Piece(s) | Same day | 96 ~ 100 | DC24V | 4 | European format | CE / UL / CUL / TUV | 55 ~ 90 | 55 ~ 90 | 100 | 4 | - | - | 85~264VAC; 120~370VDC | Cold start, 30A at 115VAC, 60A at 230VAC | 0~+20% rated output voltage | 86% | 105%~150% constant current limiting, auto-recovery | 125%~150% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -10~+60°C | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) | ||
1,448,431 VND | 1 Piece(s) | 7 Day(s) | 75 | DC24V | 3.2 | - | UL / TUV | 32 | 125.2 | 102 | - | - | - | 90~264VAC; 127~370VDC | Cold start, 35A at 230VAC | 12V: 12~14V, 24V: 24~28V, 48V: 48~55V | 88.0% | 105%~130% Constant current limiting, auto-recovery | 12V: 14~17V, 24V: 29~33V, 48V: 56~65V Shut down o/p voltage, re-power on to recover | I/P-O/P: 3kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC | -20~+70°C (refer to output derating curve) | UL508, TUV EN60950-1 approved | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(EN50082-2), EN61204-3 | ||
1,752,154 VND | 1 Piece(s) | 7 Day(s) | 120 | DC24V | 5 | - | UL / TUV | 40 | 125.2 | 113.5 | - | - | - | 90~264VAC; 127~370VDC | Cold start, 35A at 230VAC | 12V: 12~14V, 24V: 24~28V, 48V: 48~55V | 88.0% | 105%~130% Constant current limiting, auto-recovery | 12V: 14~17V, 24V: 29~33V, 48V: 56~65V Shut down o/p voltage, re-power on to recover | I/P-O/P: 3kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC | -20~+70°C (refer to output derating curve) | UL508, TUV EN60950-1 approved | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(EN50082-2), EN61204-3 | ||
4,421,123 VND | 1 Piece(s) | Same day | 480 | DC24V | 20 | European format | CE / UL / CUL / TUV | 85.5 ~ 125.2 | 85.5 ~ 125.2 | 128.5 | 20 | - | - | 90~264VAC; 127~370VDC | Cold start, 80A at 230VAC | 12V: 12~14V (only for SDR-75/120), 24V: 24~28V, 48V: 48~55V | 94% | Normally works within 110%~150% rated output power for 3 seconds and then shut down output voltage with auto-recovery (re-power on to recover for SDR-75) , >150% rated power or short circuit, constant current limiting with auto-recovery within 2 seconds and may cause to shut down if over 2 seconds | 14~17V for 12V model(SDR-75/120), 29~33V for 24V model, 56~65V for 48V model Shut down o/p voltage with auto-recovery, or re-power on to recover | I/P-O/P:3kVAC, I/P-FG:1.5kVAC, O/P-FG:0.5kVAC, O/P-DC OK:0.5kVAC (except for SDR-75) | -25~+70°C (refer to output derating curve) | UL508, TUV EN60950-1, GL (SDR-120/240/480) approved | EN55011(SDR-120/240/480), EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), EN61204-3; SEMI (SDR-75/120/240/480), GL (SDR-120/240/480) | ||
3,162,287 VND | 1 Piece(s) | 7 Day(s) | 120 | DC24V | 5 | - | UL | 40 | 125.2 | 113.5 | - | - | - | 180~550VAC(single and two phase); 254~780VDC | Cold start, 50A at 400VAC | 12V: 12~15V, 24V: 24~29V, 48V: 48~58V | 91% | 105%~130% rated output power, constant current limiting, auto-recovery | 16~18V for 12V model (only for WDR-120), 29~33V for 24V model, 56~65V for 48V model Shut down o/p voltage, auto-recovery | I/P-O/P:3kVAC, I/P-FG:1.5kVAC, O/P-FG:0.5kVAC, O/P-DC OK:0.5kVAC, 1 minute | -25~+70°C (refer to output derating curve) | UL508 approved ; IEC60950-1 CB approved by SIQ ; Design refer to GL | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level | ||
6,125,741 VND | 1 Piece(s) | 7 Day(s) | 240 | DC24V | 10 | - | UL | 63 | 125.2 | 113.5 | - | - | - | 180~550VAC(single and two phase); 254~780VDC | Cold start, 50A at 400VAC | 24V: 24~28V, 48V: 48~55V | 91% | 105%~130% rated output power, constant current limiting, unit will shut down after 3 sec.; auto-recovery after 1 minute if the fault condiction is removed. | 16~18V for 12V model (only for WDR-120), 29~33V for 24V model, 56~65V for 48V model Shut down o/p voltage, auto-recovery after 1 minute if the fault condition is removed | I/P-O/P:3kVAC, I/P-FG:1.5kVAC, O/P-FG:0.5kVAC, O/P-DC OK:0.5kVAC, 1 minute | -30~+70°C (refer to output derating curve) | UL508 approved ; IEC60950-1 CB approved by SIQ ; Design refer to GL | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level | ||
8,620,596 VND | 1 Piece(s) | 7 Day(s) | 480 | DC24V | 20 | - | UL | 85.5 | 125.2 | 128.5 | - | - | - | 180~550VAC(single and two phase); 254~780VDC | Cold start, 50A at 400VAC | 24V: 24~28V, 48V: 48~55V | 92% | 105%~130% rated output power, constant current limiting, unit will shut down after 3 sec.; auto-recovery after 1 minute if the fault condiction is removed. | 16~18V for 12V model (only for WDR-120), 29~33V for 24V model, 56~65V for 48V model Shut down o/p voltage, auto-recovery after 1 minute if the fault condition is removed | I/P-O/P:3kVAC, I/P-FG:1.5kVAC, O/P-FG:0.5kVAC, O/P-DC OK:0.5kVAC, 1 minute | -30~+70°C (refer to output derating curve) | UL508 approved ; IEC60950-1 CB approved by SIQ ; Design refer to GL | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level |
Loading...Tải…
Shape | DIN rail direct attachment | Single/multi | Single | Input Voltage | AC/DC |
---|
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy