(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.

  • Viewed
    Products
    Sản phẩm
    đã xem
    최근 본
    상품
    查看产品 查看產品
  • My
    Components
    Linh kiện
    của tôi
    나의 부품 我的部件 我的部件
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • MISUMI Việt Nam đồng hành cùng Kỹ sư tương lai trong cuộc thi SMAE Award 2024. Xem chi tiết.
    MISUMI Vietnam accompanies Future Engineers in the SMAE Award 2024 competition. See more.  

Switching Power Supply (DIN Series)

Switching Power Supply (DIN Series)
You can add up to 6 items per a category to the compare list.

Part Number :
    • From :
      624,900VND/Unit
  • Order Qty :
  • Total Price :
    ---
  • Days to ship :
    ---

Select part number to Order Now/ Add to Cart

Product Description

[Features]· Universal AC input / Full range· Installed on DIN rail TS35 / 7.5 or 15· Protections: Short circuit / Overload / Overvoltage· No load power consumption <0.75 W (<1 W for MDR-100)· LED indicator for power on· NEC class 2 / LPS compliant (selected models)· Built-in active PFC and over temp. protection (MDR-100)· DC OK signal output (MDR-10/20)· DC OK relay contact (MDR-40/60/100)· Cooling by free air convection· 100% full load burn-in test

 
Part Number
EDR-75-24
EDR-120-24
EDR-150-24
MDR-10-5
MDR-10-12
MDR-10-24
MDR-20-5
MDR-20-12
MDR-20-24
MDR-40-12
MDR-40-24
MDR-60-12
MDR-60-24
MDR-100-12
MDR-100-24
NDR-75-24
NDR-120-24
SDR-75-12
SDR-75-24
SDR-120-12
SDR-240-12
SDR-240-24
SDR-480-24
WDR-120-24
WDR-240-24
WDR-480-24
Part NumberPriceMinimum Order Qty.Volume DiscountDays to ShipSố ngày giao hàngCapacity
(W)
Output voltage (Single only) Rated output current (single only)
(A)
Input/output terminal shape Representative Standard Dimension height
(mm)
Dimension width
(mm)
Dimension depth
(mm)
Rated output current 1 for DC 24 V
(A)
Rated output current 2 for DC 12 V
(A)
Rated output current 3 for DC 5 V
(A)
AC Input Voltage Range AC Input current (Maximum) DC adjustment range Effi. Overload protection Over voltage protection Withstand Voltage Operating temperature Safety Standard EMC standards

1,170,744 VND

1 Piece(s) 4 Day(s) 75DC24V3.2-UL / TUV32125.2102---90~264VAC; 127~370VDCCold start, 35A at 230VAC12V: 12~14V, 24V: 24~28V, 48V: 48~55V87.5%105%~130% Constant current limiting, auto-recovery12V: 14~17V, 24V: 29~33V, 48V: 56~65V Shut down o/p voltage, re-power on to recoverI/P-O/P: 3kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC-20~+60°C (refer to output derating curve)UL508, TUV EN60950-1 approvedEN55022 classA, EN61000-3-2(125W for EDR-150),3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(EN50082-2)

1,500,499 VND

1 Piece(s) 7 Day(s) 120DC24V5-UL / TUV32125.2102---90~264VAC; 127~370VDCCold start, 35A at 230VAC12V: 12~14V, 24V: 24~28V, 48V: 48~55V87.5%105%~130% Constant current limiting, auto-recovery12V: 14~17V, 24V: 29~33V, 48V: 56~65V Shut down o/p voltage, re-power on to recoverI/P-O/P: 3kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC-20~+60°C (refer to output derating curve)UL508, TUV EN60950-1 approvedEN55022 classA, EN61000-3-2(125W for EDR-150),3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(EN50082-2)

1,587,276 VND

1 Piece(s) 7 Day(s) 150DC24V6.5-UL / TUV40125.2113.5---90~264VAC; 127~370VDCCold start, 35A at 230VAC12V: 12~14V, 24V: 24~28V, 48V: 48~55V87%105%~130% Constant current limiting, auto-recovery24V: 29~33V Shut down o/p voltage, re-power on to recoverI/P-O/P: 3kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC-20~+60°C (refer to output derating curve)UL508, TUV EN60950-1 approvedEN55022 classA, EN61000-3-2(125W for EDR-150),3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(EN50082-2)

701,370 VND

1 Piece(s) 4 Day(s) or more 10DC5V2European formatCE / UL / CUL / TUV22.5 ~ 9022.5 ~ 90100--285~264VAC; 120~370VDCCold start, 35A at 115VAC, 70A at 230VACFixed77%>105% hiccup mode, auto-recovery115%~135% rated output voltageI/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute-20~+70°C (refer to output derating curve)UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100)

701,370 VND

1 Piece(s) 4 Day(s) or more 10DC12V0.84European formatCE / UL / CUL / TUV22.5 ~ 9022.5 ~ 90100-0.84-85~264VAC; 120~370VDCCold start, 35A at 115VAC, 70A at 230VACFixed81%>105% hiccup mode, auto-recovery115%~135% rated output voltageI/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute-20~+70°C (refer to output derating curve)UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100)

701,370 VND

1 Piece(s) 4 Day(s) or more 10DC24V0.42European formatCE / UL / CUL / TUV22.5 ~ 9022.5 ~ 901000.42--85~264VAC; 120~370VDCCold start, 35A at 115VAC, 70A at 230VACFixed84%>105% hiccup mode, auto-recovery115%~135% rated output voltageI/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute-20~+70°C (refer to output derating curve)UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100)

624,900 VND

1 Piece(s) 4 Day(s) or more 20DC5V3European formatCE / UL / CUL / TUV22.5 ~ 9022.5 ~ 90100--385~264VAC; 120~370VDCCold start, 20A at 115VAC, 40A at 230VAC±10% rated output voltage76%105%~160% constant current limiting, auto-recovery115%~135% rated output voltageI/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute-20~+70°C (refer to output derating curve)UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100)

624,900 VND

1 Piece(s) 4 Day(s) or more 20DC12V1.67European formatCE / UL / CUL / TUV22.5 ~ 9022.5 ~ 90100-1.67-85~264VAC; 120~370VDCCold start, 20A at 115VAC, 40A at 230VAC±10% rated output voltage80%105%~160% constant current limiting, auto-recovery115%~135% rated output voltageI/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute-20~+70°C (refer to output derating curve)UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100)

797,012 VND

1 Piece(s) 4 Day(s) or more 20 ~ 24DC24V1European formatCE / UL / CUL / TUV22.5 ~ 9022.5 ~ 901001--85~264VAC; 120~370VDCCold start, 20A at 115VAC, 40A at 230VAC±10% rated output voltage84%105%~160% constant current limiting, auto-recovery115%~135% rated output voltageI/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute-20~+70°C (refer to output derating curve)UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100)

749,880 VND

1 Piece(s) 4 Day(s) or more 40DC12V3.33European formatCE / UL / CUL / TUV40 ~ 9040 ~ 90100-3.33-85~264VAC; 120~370VDCCold start, 30A at 115VAC, 60A at 230VAC0~+20% rated output voltage86%105%~150% constant current limiting, auto-recovery125%~150% rated output voltageI/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute-20~+70°C (refer to output derating curve)UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100)

956,414 VND

1 Piece(s) 4 Day(s) or more 40 ~ 40.8DC24V1.7European formatCE / UL / CUL / TUV40 ~ 9040 ~ 901001.7--85~264VAC; 120~370VDCCold start, 30A at 115VAC, 60A at 230VAC0~+20% rated output voltage88%105%~150% constant current limiting, auto-recovery125%~150% rated output voltageI/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute-20~+70°C (refer to output derating curve)UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100)

849,864 VND

1 Piece(s) 4 Day(s) or more 60DC12V5European formatCE / UL / CUL / TUV40 ~ 9040 ~ 90100-5-85~264VAC; 120~370VDCCold start, 30A at 115VAC, 60A at 230VAC0~+20% rated output voltage86%105%~150% constant current limiting, auto-recovery125%~150% rated output voltageI/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute-20~+70°C (refer to output derating curve)UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100)

1,083,936 VND

1 Piece(s) Same day ---------------------

1,324,788 VND

1 Piece(s) 4 Day(s) or more 100DC12V7.5European formatCE / UL / CUL / TUV55 ~ 9055 ~ 90100-7.5-85~264VAC; 120~370VDCCold start, 30A at 115VAC, 60A at 230VAC0~+20% rated output voltage83%105%~150% constant current limiting, auto-recovery125%~150% rated output voltageI/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute-10~+60°CUL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100)

1,689,666 VND

1 Piece(s) Same day 96 ~ 100DC24V4European formatCE / UL / CUL / TUV55 ~ 9055 ~ 901004--85~264VAC; 120~370VDCCold start, 30A at 115VAC, 60A at 230VAC0~+20% rated output voltage86%105%~150% constant current limiting, auto-recovery125%~150% rated output voltageI/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute-10~+60°CUL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100)

1,448,431 VND

1 Piece(s) 7 Day(s) 75DC24V3.2-UL / TUV32125.2102---90~264VAC; 127~370VDCCold start, 35A at 230VAC12V: 12~14V, 24V: 24~28V, 48V: 48~55V88.0%105%~130% Constant current limiting, auto-recovery12V: 14~17V, 24V: 29~33V, 48V: 56~65V Shut down o/p voltage, re-power on to recoverI/P-O/P: 3kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC-20~+70°C (refer to output derating curve)UL508, TUV EN60950-1 approvedEN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(EN50082-2), EN61204-3

1,752,154 VND

1 Piece(s) 7 Day(s) 120DC24V5-UL / TUV40125.2113.5---90~264VAC; 127~370VDCCold start, 35A at 230VAC12V: 12~14V, 24V: 24~28V, 48V: 48~55V88.0%105%~130% Constant current limiting, auto-recovery12V: 14~17V, 24V: 29~33V, 48V: 56~65V Shut down o/p voltage, re-power on to recoverI/P-O/P: 3kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC-20~+70°C (refer to output derating curve)UL508, TUV EN60950-1 approvedEN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(EN50082-2), EN61204-3

1,734,797 VND

1 Piece(s) 7 Day(s) 75DC12V6.3-UL / TUV32125.2102---88~264VAC; 124~370VDCCold start, 50A at 230VAC12V: 12~14V (only for SDR-75/120), 24V: 24~28V, 48V: 48~55V88.5%Normally works within 110%~150% rated output power for 3 seconds and then shut down output voltage with auto-recovery (re-power on to recover for SDR-75) , >150% rated power or short circuit, constant current limiting with auto-recovery within 2 seconds and may cause to shut down if over 2 seconds14~17V for 12V model(SDR-75/120), 29~33V for 24V model, 56~65V for 48V model Shut down o/p voltage, re-power on to recoverI/P-O/P:3kVAC, I/P-FG:1.5kVAC, O/P-FG:0.5kVAC, O/P-DC OK:0.5kVAC (except for SDR-75)-30~+70°CUL508, TUV EN60950-1, GL (SDR-120/240/480) approvedEN55011(SDR-120/240/480), EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), EN61204-3; SEMI (SDR-75/120/240/480), GL (SDR-120/240/480)

1,734,797 VND

1 Piece(s) 7 Day(s) 75DC24V3.2-UL / TUV32125.2102---88~264VAC; 124~370VDCCold start, 50A at 230VAC12V: 12~14V (only for SDR-75/120), 24V: 24~28V, 48V: 48~55V89.0%Normally works within 110%~150% rated output power for 3 seconds and then shut down output voltage with auto-recovery (re-power on to recover for SDR-75) , >150% rated power or short circuit, constant current limiting with auto-recovery within 2 seconds and may cause to shut down if over 2 seconds14~17V for 12V model(SDR-75/120), 29~33V for 24V model, 56~65V for 48V model Shut down o/p voltage, re-power on to recoverI/P-O/P:3kVAC, I/P-FG:1.5kVAC, O/P-FG:0.5kVAC, O/P-DC OK:0.5kVAC (except for SDR-75)-30~+70°CUL508, TUV EN60950-1, GL (SDR-120/240/480) approvedEN55011(SDR-120/240/480), EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), EN61204-3; SEMI (SDR-75/120/240/480), GL (SDR-120/240/480)

2,958,361 VND

1 Piece(s) 7 Day(s) 120DC12V10-UL / TUV40125.2113.5---88~264VAC; 124~370VDCCold start, 70A at 230VAC12V: 12~14V (only for SDR-75/120), 24V: 24~28V, 48V: 48~55V89.0%Normally works within 110%~150% rated output power for 3 seconds and then shut down output voltage with auto-recovery (re-power on to recover for SDR-75) , >150% rated power or short circuit, constant current limiting with auto-recovery within 2 seconds and may cause to shut down if over 2 seconds14~17V for 12V model(SDR-75/120), 29~33V for 24V model, 56~65V for 48V model Shut down o/p voltage, re-power on to recoverI/P-O/P:3kVAC, I/P-FG:1.5kVAC, O/P-FG:0.5kVAC, O/P-DC OK:0.5kVAC (except for SDR-75)-25~+70°C (refer to output derating curve)UL508, TUV EN60950-1, GL (SDR-120/240/480) approvedEN55011(SDR-120/240/480), EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), EN61204-3; SEMI (SDR-75/120/240/480), GL (SDR-120/240/480)

4,850,111 VND

1 Piece(s) 7 Day(s) 240DC48V5-UL / TUV63125.2113.5---88~264VAC; 124~370VDCCold start, 65A at 230VAC12V: 12~14V (only for SDR-75/120), 24V: 24~28V, 48V: 48~55V-Normally works within 110%~150% rated output power for 3 seconds and then shut down output voltage with auto-recovery (re-power on to recover for SDR-75) , >150% rated power or short circuit, constant current limiting with auto-recovery within 2 seconds and may cause to shut down if over 2 seconds14~17V for 12V model(SDR-75/120), 29~33V for 24V model, 56~65V for 48V model Shut down o/p voltage with auto-recovery, or re-power on to recoverI/P-O/P:3kVAC, I/P-FG:1.5kVAC, O/P-FG:0.5kVAC, O/P-DC OK:0.5kVAC (except for SDR-75)-25~+70°C (refer to output derating curve)UL508, TUV EN60950-1, GL (SDR-120/240/480) approvedEN55011(SDR-120/240/480), EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), EN61204-3; SEMI (SDR-75/120/240/480), GL (SDR-120/240/480)

3,974,364 VND

1 Piece(s) Same day ---------------------

4,421,123 VND

1 Piece(s) Same day 480DC24V20European formatCE / UL / CUL / TUV85.5 ~ 125.285.5 ~ 125.2128.520--90~264VAC; 127~370VDCCold start, 80A at 230VAC12V: 12~14V (only for SDR-75/120), 24V: 24~28V, 48V: 48~55V94%Normally works within 110%~150% rated output power for 3 seconds and then shut down output voltage with auto-recovery (re-power on to recover for SDR-75) , >150% rated power or short circuit, constant current limiting with auto-recovery within 2 seconds and may cause to shut down if over 2 seconds14~17V for 12V model(SDR-75/120), 29~33V for 24V model, 56~65V for 48V model Shut down o/p voltage with auto-recovery, or re-power on to recoverI/P-O/P:3kVAC, I/P-FG:1.5kVAC, O/P-FG:0.5kVAC, O/P-DC OK:0.5kVAC (except for SDR-75)-25~+70°C (refer to output derating curve)UL508, TUV EN60950-1, GL (SDR-120/240/480) approvedEN55011(SDR-120/240/480), EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), EN61204-3; SEMI (SDR-75/120/240/480), GL (SDR-120/240/480)

3,162,287 VND

1 Piece(s) 7 Day(s) 120DC24V5-UL40125.2113.5---180~550VAC(single and two phase); 254~780VDCCold start, 50A at 400VAC12V: 12~15V, 24V: 24~29V, 48V: 48~58V91%105%~130% rated output power, constant current limiting, auto-recovery16~18V for 12V model (only for WDR-120), 29~33V for 24V model, 56~65V for 48V model Shut down o/p voltage, auto-recoveryI/P-O/P:3kVAC, I/P-FG:1.5kVAC, O/P-FG:0.5kVAC, O/P-DC OK:0.5kVAC, 1 minute-25~+70°C (refer to output derating curve)UL508 approved ; IEC60950-1 CB approved by SIQ ; Design refer to GLEN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level

6,125,741 VND

1 Piece(s) 7 Day(s) 240DC24V10-UL63125.2113.5---180~550VAC(single and two phase); 254~780VDCCold start, 50A at 400VAC24V: 24~28V, 48V: 48~55V91%105%~130% rated output power, constant current limiting, unit will shut down after 3 sec.; auto-recovery after 1 minute if the fault condiction is removed.16~18V for 12V model (only for WDR-120), 29~33V for 24V model, 56~65V for 48V model Shut down o/p voltage, auto-recovery after 1 minute if the fault condition is removedI/P-O/P:3kVAC, I/P-FG:1.5kVAC, O/P-FG:0.5kVAC, O/P-DC OK:0.5kVAC, 1 minute-30~+70°C (refer to output derating curve)UL508 approved ; IEC60950-1 CB approved by SIQ ; Design refer to GLEN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level

8,620,596 VND

1 Piece(s) 7 Day(s) 480DC24V20-UL85.5125.2128.5---180~550VAC(single and two phase); 254~780VDCCold start, 50A at 400VAC24V: 24~28V, 48V: 48~55V92%105%~130% rated output power, constant current limiting, unit will shut down after 3 sec.; auto-recovery after 1 minute if the fault condiction is removed.16~18V for 12V model (only for WDR-120), 29~33V for 24V model, 56~65V for 48V model Shut down o/p voltage, auto-recovery after 1 minute if the fault condition is removedI/P-O/P:3kVAC, I/P-FG:1.5kVAC, O/P-FG:0.5kVAC, O/P-DC OK:0.5kVAC, 1 minute-30~+70°C (refer to output derating curve)UL508 approved ; IEC60950-1 CB approved by SIQ ; Design refer to GLEN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level

Loading...Tải…

  1. 1

Basic InformationThông tin cơ bản

Shape DIN rail direct attachment Single/multi Single Input Voltage AC/DC