(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
A high speed counter for the micro sequencer MELSEC-F series
FX3U-2HC image
Number of Input Channels | 2 ch | |
---|---|---|
Input Format | Open collector, differential line driver (differential line driver output type encoder is connected to the 5 V terminal) | |
Input Voltage | Selected from 5, 12 or 24 V DC depending on the connection terminal | |
Maximum Response Frequency | 1-Phase 1 Input | 200 kHz or less |
1-Phase 2 Inputs | 200 kHz or less | |
2-Phase Input | 200 kHz or less (multiplied by 1), 100 kHz or less (multiplied by 2), 50 kHz or less (multiplied by 4) | |
Count Range | At 32-bit specification: -2,147,483,648 to +2,147,483,647 At 16-bit specification: 0 to 65,535 (upper limit can be specified with BFM #3, #2, #43, #42) | |
Count Mode | Automatic up/down (The counting direction of the 1-phase 1 input counter is determined by the following command) [H/W up/down] Counts up/down by OFF/ON of the A-phase input terminal. [S/W up/down] Counts up/down by the current value (K0/K1) of BFM #1, #41. | |
Matching Output (Comparison) | When the current value of the counter and the comparison setting match, the comparison output is set (ON) within 30 μs, and is cleared (OFF) within 100 μs by the reset command. | |
Output Format | Open collector output, 2 points, 5 to 24 V DC at 0.5 A each | |
Display (LED) | øA, øB, DIS, PRE, YH1, YH2, POWER, UP, DOWN | |
Number of Occupied Inputs/Outputs | 8 points (either input or output can be considered) | |
Applicable Sequencers | FX5U, FX5UC, FX3U (V2.20 or later), FX3UC (V2.20 or later) "Connection to FX5U or FX5U CPU unit" Connection to FX5U or FX5UC requires FX5-CNV-BUS or FX5-CNV-BUSC. Select either one according to the system configuration. "Connection to connector type sequencer" Connection to FX3UC requires either FX2NC-CNV-IF or FX3UC-1PS-5V. | |
Weight | 0.2 kg | |
Power Supply Specifications | ||
Power Supply | 5 V DC, 245 mA (internal power supply from sequencer) |
Ambient Temperature | 0 to 55°C: When operating, -25 to 75°C: When stored | ||
---|---|---|---|
Relative Humidity | 5 to 95% RH (non-condensing): When operating | ||
Vibration Resistance | When Mounting to DIN Rail | Frequency: 10 to 57 Hz | Single amplitude: 0.035 mm, 10 times in each direction of X, Y and Z (total of 80 minutes each) |
Frequency: 57 to 150 Hz | Acceleration: 4.9 m/s2 10 times in each direction of X, Y and Z (total of 80 minutes each) | ||
When Mounting Directly | Frequency: 10 to 57 Hz | Single amplitude: 0.075 mm 10 times in each direction of X, Y and Z (total of 80 minutes each) | |
Frequency: 57 to 150 Hz | Acceleration: 9.8 m/s2 10 times in each direction of X, Y and Z (total of 80 minutes each) | ||
Impact Resistant | 147 m/s2, for a duration of 11 ms, 3 times in each direction of X, Y and Z with a half-sine pulse | ||
Noise Resistance | Achieved through a noise simulator with a noise voltage of 1,000 Vp-p, noise width of 1 μs, the rise time of 1 ns, and frequency of 30 to 100 Hz | ||
Withstand Voltage | Between all terminals batch and earth terminal: 500 V AC for 1 minute | ||
Insulation Resistance | Between all terminals batch and earth terminal: 5 MΩ or more with 500 V DC ohmmeter | ||
Grounding | Class D grounding (ground resistance: 100 Ω or less) "Shared grounding with a high-power system is not allowed" Use dedicated or shared ground. | ||
Operating Atmosphere | There shall be no corrosion gas or flammable gas and not much conductive dust | ||
Altitude of Use | 2,000 m or less Cannot be used in environments pressurized above atmospheric pressure. This may cause failure. |
Part Number |
---|
FX3U-2HC |
FX3U-4HSX-ADP |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Number of Channels (ch) | Count Input Format | Maximum Response Frequency (1 Phase, 1 Input) | Maximum Response Frequency (1 Phase, 2 Input) | Maximum Response Frequency (2 Phase Input) |
---|---|---|---|---|---|---|---|---|---|
6,422,500 VND | 1 Piece(s) | Quote | 2 | Open Collector Differential Line Driver | 200 kHz or Less | 200 kHz or Less | 200 kHz or Less (1 Multiplication), 100 kHz or Less (2 Multiplication), 50 kHz or Less (4 Multiplication) | ||
5,505,000 VND | 1 Piece(s) | Quote | 4 | Differential Line Receiver | 200 kHz or less (according to sequence program) | 200 kHz or less (according to sequence program) | 100kHz or less (according to sequence program) |
Loading...Tải…
Type | Counter |
---|
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy