(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Caution
thận trọng
A step data input type electric actuator.
[Features]
· Already set with actuator data when shipped. (Actuator and controller are provided as a set)
· Easy mode for simple setting and normal mode for detailed setting.
· Teaching box, controller setting software.
· Number of step data: 64 points.
· Completion signal: (INP) output.
Step motor (24‑V DC servo) LECP6 Series external appearance
Servo motor (24 V DC) LECA6 Series external appearance
Item | LECP6 | LECA6 |
---|---|---|
Compatible Motor | Step motor (24‑V DC servo) | Servo motor (24 V DC) |
Power Supply Specifications Note 1: | Power voltage: 24 V DC ±10% Note 2: [Including motor drive power, control power, stop, lock release] | Power voltage: 24 V DC ±10% Note 2: [Including motor drive power, control power, stop, lock release] |
Parallel Input | 11 inputs (photo-coupler isolation) | |
Parallel Output | 13 outputs (photo-coupler isolation) | |
Compatible Encoder | Incremental A/B phase (800 pulses/rotation) | Incremental A/B (800 pulses/rotation) / Z phase |
Serial Communication | RS485 (Modbus protocol compliant) | |
Memory | EEPROM | |
LED Indicator | LED (green/red), 1 pc. each | |
Lock Control | With forced-lock release terminal Note 3: | |
Cable Length [m] | I/O cable: 5 or less, Actuator cable: 20 or less | |
Cooling System | Natural air cooling | |
Operating Temperature Range [°C] | 0 to 40 (no freezing) | |
Operating Humidity Range [%RH] | 90 or less (no condensation) | |
Storage Temperature Range [°C] | -10 to 60 (no freezing) | |
Storage Humidity Range [%RH] | 90 or less (no condensation) | |
Insulation Resistance [MΩ] | Between housing and SG terminal: 50 (500 V DC) | |
Weight [g] | 150 (screw mounting type), 170 (DIN rail mounting type) |
Note 1: Use a power supply other than the "inrush current prevention type" for the controller input DC power supply. When conformity to UL is required, use with a UL1310 Class 2 power supply.
Note 2: The power consumption changes depending on the actuator model. Refer to the actuator specifications for more details.
Note 3: Compatible with non-magnetizing lock.
(Units: mm)
Screw mounting (LEC□6□□-□) dimensional drawing
DIN rail mounting (LEC□6□□D-□) dimensional drawing
*Refer to the manufacturer's catalog for DIN rail L dimensions and part numbers.
Screw mounting (LEC□6□□-□) (use 2 × M4 screws)
DIN rail mounting (LEC□6□□D-□) (use DIN rail)
Power supply plug for LECP6 (image of LEC-D-1-1)
CN1 Power Supply Connector Terminals for LECP6
(FK-MC0.5/5-ST-2.5)
Terminal Name | Function | Function Details |
---|---|---|
0 V | Common supply (-) | M 24‑V terminal / C 24‑V terminal / EMG terminal / BK RLS terminal are common (-). |
M24V | Motor power supply (+) | Motor power supply (+) side supplies to the controller. |
C24V | Control power supply (+) | Control power supply (+) side supplies to the controller. |
EMG | Stop (+) | Input (+) for releasing the stop. |
BK RLS | Lock release (+) | Input (+) for releasing the lock. |
Power supply plug for LECA6 (image of LEC-D-1-2)
CN1 Power Supply Connector Terminals for LECA6
(FK-MC0.5/7-ST-2.5)
Terminal Name | Function | Function Details |
---|---|---|
0 V | Common supply (-) | M 24‑V terminal / C 24‑V terminal / EMG terminal / BK RLS terminal are common (-). |
M24V | Motor power supply (+) | Motor power supply (+) side supplies to the controller. |
C24V | Control power supply (+) | Control power supply (+) side supplies to the controller. |
EMG | Stop (+) | Input (+) for releasing the stop. |
BK RLS | Lock release (+) | Input (+) for releasing the lock. |
RG+ | Regenerative output 1 | Regenerative output terminals for external connection. (Not necessary to connect them in the combination with the LE Series standard specifications.) |
RG- | Regenerative output 2 |
*Power supply plug is an accessory.
LEC□6N□□-□ (NPN) wiring diagram
LEC□6P□□-□ (PNP) wiring diagram
Input Signal Details
Name | Details |
---|---|
COM+ | Connects the 24‑V side of the 24‑V DC power supply for the input/output signal |
COM- | Connects the 0‑V side of the 24‑V DC power supply for the input/output signal |
IN0 to IN5 | Step data specified Bit No. (Input is instructed for the combinations IN0 to 5) |
SETUP | Instruction to return to origin |
HOLD | Operation is temporarily stopped |
DRIVE | Instruction to drive |
RESET | Alarm reset and interruption of operation |
SVON | Servo ON instruction |
Output Signal Details
Name | Details |
---|---|
OUT0 to OUT5 | Outputs the step data no. during operation |
BUSY | Outputs when the actuator is moving |
AREA | Outputs within the step data area output setting range |
SETON | Outputs when returning to origin |
INP | ON when target position or target force is reached (Turns ON when the positioning or pushing is completed) |
SVRE | Outputs when servo is ON |
*ESTOP Note: | No output when EMG stop is instructed |
*ALARM Note: | No output when alarm is generated |
Note: Signal of negative-logic circuit (N.C.)
Part Number |
---|
LECA6N1-LEFB25AT-800 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Input Power Supply | Position Detection | I/O Module | Size | Motor type | Step data (points) | Actuator/cable type | I/O cable length / communication plug (m) | Controller/driver mounting method |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | DC24V | Incremental | NPN | - | Servo motor (24 V DC) | 64 | LEFB25AT-800 | 1.5 | Screw mounting type |
Loading...Tải…
Main Body, Peripheral Components | Peripheral Components |
---|
Please check the type/dimensions/specifications of the part LECA6N1-LEFB25AT-800 in the Controller (Step Data Input Type) LECP6 (Step Motor) / LECA6 (Servo Motor) Series series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần LECA6N1-LEFB25AT-800 trong chuỗi Controller (Step Data Input Type) LECP6 (Step Motor) / LECA6 (Servo Motor) Series.
Part Number |
---|
LECA6N-LEFB25AT-1000 |
LECA6N-LEFB25AT-500 |
LECA6N-LEFB25AT-600 |
LECA6N1-LEFS16AA-150 |
LECA6N1-LEFS16AA-200 |
LECA6N1-LEFS16AA-300 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to ShipSố ngày giao hàng | Input Power Supply | Position Detection | I/O Module | Size | Motor type | Step data (points) | Actuator/cable type | I/O cable length / communication plug (m) | Controller/driver mounting method |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | DC24V | Incremental | NPN | - | Servo motor (24 V DC) | 64 | LEFB25AT-1000 | Without I/O cable | Screw mounting type | ||
- | 1 Piece(s) | Quote | DC24V | Incremental | NPN | - | Servo motor (24 V DC) | 64 | LEFB25AT-500 | Without I/O cable | Screw mounting type | ||
- | 1 Piece(s) | Quote | DC24V | Incremental | NPN | - | Servo motor (24 V DC) | 64 | LEFB25AT-600 | Without I/O cable | Screw mounting type | ||
- | 1 Piece(s) | Quote | DC24V | Incremental | NPN | - | Servo motor (24 V DC) | 64 | LEFS16AA-150 | 1.5 | Screw mounting type | ||
9,726,000 VND | 1 Piece(s) | 32 Day(s) | DC24V | Incremental | NPN | - | Servo motor (24 V DC) | 64 | LEFS16AA-200 | 1.5 | Screw mounting type | ||
9,726,000 VND | 1 Piece(s) | 32 Day(s) | DC24V | Incremental | NPN | - | Servo motor (24 V DC) | 64 | LEFS16AA-300 | 1.5 | Screw mounting type |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy