(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Maximum Intake Flow Rate | Number of Vacuum Stacks | Lead wire takeout | Sealing material | Air supply valve | Vacuum Breaking Valve | Intake Flow Rate at Vacuum Level of 0 kPa (Nl/min) (Nl/m) | Noise level (s/l) | 10kPa (Nl/m) | 20kPa (Nl/m) | 30kPa (Nl/m) | 40kPa (Nl/m) | 50kPa (Nl/m) | 60kPa (Nl/m) | 70kPa (Nl/m) | 80kPa (Nl/m) | 20kPa (s/l) | 30kPa (s/l) | 40kPa (s/l) | 50kPa (s/l) | 60kPa (s/l) | 70kPa (s/l) | 80kPa (s/l) | 90kPa | Maximum Vacuum Level | Minimum Hose Internal Diameter (within 2 m) (Air Supply) | Weight (g) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
93,998,950 VND | 1 Piece(s) | 10 Day(s) | 27 Nl/min/(1stack) | 16-layer | How to take out lead wire, DIN type superconducting (without lead wire) | NBR material | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 27 | 55~65 dBA | 16 | 13 | 12 | 11 | 8 | 6 | 2.4 | 0.66 | 0.556 | 1 | 1.576 | 2.356 | 3.44 | 5.27 | 10.216 | - | -85 kPa | >8~10 | 1069 | ||
119,038,074 VND | 1 Piece(s) | 10 Day(s) | 27 Nl/min/(1stack) | 16-layer | How to take out lead wire, DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 27 | 55~65 dBA | 16 | 13 | 12 | 11 | 8 | 6 | 2.4 | 0.66 | 0.556 | 1 | 1.576 | 2.356 | 3.44 | 5.27 | 10.216 | - | -85 kPa | >8~10 | 1069 | ||
132,520,304 VND | 1 Piece(s) | 10 Day(s) | 27 Nl/min/(1stack) | 16-layer | How to take out lead wire, DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 27 | 55~65 dBA | 16 | 13 | 12 | 11 | 8 | 6 | 2.4 | 0.66 | 0.556 | 1 | 1.576 | 2.356 | 3.44 | 5.27 | 10.216 | - | -85 kPa | >8~10 | 1069 | ||
26,301,635 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 4-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | NBR material | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 625 | ||
32,561,074 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 4-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 625 | ||
35,931,421 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 4-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 625 | ||
26,024,365 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 4-layer | How to take out lead wire, DIN type superconducting (without lead wire) | NBR material | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 625 | ||
32,283,805 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 4-layer | How to take out lead wire, DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 625 | ||
35,654,122 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 4-layer | How to take out lead wire, DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 625 | ||
26,301,635 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 4-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | NBR material | Air Control Valve, AC220V | Vacuum Release Control Valve, AC220V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 625 | ||
32,561,074 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 4-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, AC220V | Vacuum Release Control Valve, AC220V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 625 | ||
35,931,421 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 4-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, AC220V | Vacuum Release Control Valve, AC220V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 625 | ||
26,024,365 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 4-layer | How to take out lead wire, DIN type superconducting (without lead wire) | NBR material | Air Control Valve, AC220V | Vacuum Release Control Valve, AC220V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 625 | ||
32,283,805 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 4-layer | How to take out lead wire, DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, AC220V | Vacuum Release Control Valve, AC220V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 625 | ||
35,654,122 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 4-layer | How to take out lead wire, DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, AC220V | Vacuum Release Control Valve, AC220V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 625 | ||
26,221,140 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 4-layer | How to take out lead wire, flashing type connection plug (with 0.3 m lead wire) | NBR material | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 625 | ||
27,923,305 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 4-layer | How to take out lead wire, flashing type connection plug (with 0.3 m lead wire) | EPDM material sealing | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 625 | ||
31,293,622 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 4-layer | How to take out lead wire, flashing type connection plug (with 0.3 m lead wire) | VITON material sealing | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 625 | ||
26,301,635 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 4-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | NBR material | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 625 | ||
32,561,074 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 4-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 625 | ||
35,931,421 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 4-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 625 | ||
26,024,365 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 4-layer | How to take out lead wire, DIN type superconducting (without lead wire) | NBR material | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 625 | ||
32,283,805 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 4-layer | How to take out lead wire, DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 625 | ||
35,654,122 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 4-layer | How to take out lead wire, DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 625 | ||
32,035,140 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 5-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | NBR material | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 662 | ||
39,859,883 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 5-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 662 | ||
44,073,260 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 5-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 662 | ||
31,757,870 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 5-layer | How to take out lead wire, DIN type superconducting (without lead wire) | NBR material | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 662 | ||
39,582,613 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 5-layer | How to take out lead wire, DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 662 | ||
43,795,961 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 5-layer | How to take out lead wire, DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 662 | ||
32,035,140 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 5-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | NBR material | Air Control Valve, AC220V | Vacuum Release Control Valve, AC220V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 662 | ||
39,859,883 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 5-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, AC220V | Vacuum Release Control Valve, AC220V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 662 | ||
44,073,260 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 5-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, AC220V | Vacuum Release Control Valve, AC220V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 662 | ||
31,757,870 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 5-layer | How to take out lead wire, DIN type superconducting (without lead wire) | NBR material | Air Control Valve, AC220V | Vacuum Release Control Valve, AC220V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 662 | ||
39,582,613 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 5-layer | How to take out lead wire, DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, AC220V | Vacuum Release Control Valve, AC220V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 662 | ||
43,795,961 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 5-layer | How to take out lead wire, DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, AC220V | Vacuum Release Control Valve, AC220V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 662 | ||
31,954,645 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 5-layer | How to take out lead wire, flashing type connection plug (with 0.3 m lead wire) | NBR material | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 662 | ||
35,222,113 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 5-layer | How to take out lead wire, flashing type connection plug (with 0.3 m lead wire) | EPDM material sealing | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 662 | ||
39,435,461 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 5-layer | How to take out lead wire, flashing type connection plug (with 0.3 m lead wire) | VITON material sealing | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 662 | ||
32,035,140 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 5-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | NBR material | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 662 | ||
39,859,883 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 5-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 662 | ||
44,073,260 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 5-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 662 | ||
31,757,870 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 5-layer | How to take out lead wire, DIN type superconducting (without lead wire) | NBR material | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 662 | ||
39,582,613 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 5-layer | How to take out lead wire, DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 662 | ||
43,795,961 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 5-layer | How to take out lead wire, DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 662 | ||
37,764,168 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 6-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | NBR material | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 699 | ||
47,153,342 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 6-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 699 | ||
52,209,720 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 6-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 699 | ||
37,486,870 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 6-layer | How to take out lead wire, DIN type superconducting (without lead wire) | NBR material | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 699 | ||
46,876,044 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 6-layer | How to take out lead wire, DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 699 | ||
51,932,450 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 6-layer | How to take out lead wire, DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 699 | ||
37,764,168 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 6-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | NBR material | Air Control Valve, AC220V | Vacuum Release Control Valve, AC220V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 699 | ||
47,153,342 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 6-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, AC220V | Vacuum Release Control Valve, AC220V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 699 | ||
52,209,720 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 6-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, AC220V | Vacuum Release Control Valve, AC220V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 699 | ||
37,486,870 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 6-layer | How to take out lead wire, DIN type superconducting (without lead wire) | NBR material | Air Control Valve, AC220V | Vacuum Release Control Valve, AC220V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 699 | ||
46,876,044 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 6-layer | How to take out lead wire, DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, AC220V | Vacuum Release Control Valve, AC220V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 699 | ||
51,932,450 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 6-layer | How to take out lead wire, DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, AC220V | Vacuum Release Control Valve, AC220V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 699 | ||
37,683,674 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 6-layer | How to take out lead wire, flashing type connection plug (with 0.3 m lead wire) | NBR material | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 699 | ||
42,515,544 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 6-layer | How to take out lead wire, flashing type connection plug (with 0.3 m lead wire) | EPDM material sealing | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 699 | ||
47,571,950 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 6-layer | How to take out lead wire, flashing type connection plug (with 0.3 m lead wire) | VITON material sealing | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 699 | ||
37,764,168 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 6-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | NBR material | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 699 | ||
47,153,342 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 6-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 699 | ||
52,209,720 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 6-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 699 | ||
37,486,870 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 6-layer | How to take out lead wire, DIN type superconducting (without lead wire) | NBR material | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 699 | ||
46,876,044 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 6-layer | How to take out lead wire, DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 699 | ||
51,932,450 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 6-layer | How to take out lead wire, DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 699 | ||
43,506,598 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 7-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | NBR material | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 736 | ||
54,461,075 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 7-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 736 | ||
60,360,047 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 7-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 736 | ||
43,229,328 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 7-layer | How to take out lead wire, DIN type superconducting (without lead wire) | NBR material | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 736 | ||
54,183,806 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 7-layer | How to take out lead wire, DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 736 | ||
60,082,777 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 7-layer | How to take out lead wire, DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 736 | ||
43,506,598 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 7-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | NBR material | Air Control Valve, AC220V | Vacuum Release Control Valve, AC220V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 736 | ||
54,461,075 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 7-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, AC220V | Vacuum Release Control Valve, AC220V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 736 | ||
60,360,047 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 7-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, AC220V | Vacuum Release Control Valve, AC220V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 736 | ||
43,229,328 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 7-layer | How to take out lead wire, DIN type superconducting (without lead wire) | NBR material | Air Control Valve, AC220V | Vacuum Release Control Valve, AC220V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 736 | ||
54,183,806 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 7-layer | How to take out lead wire, DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, AC220V | Vacuum Release Control Valve, AC220V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 736 | ||
60,082,777 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 7-layer | How to take out lead wire, DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, AC220V | Vacuum Release Control Valve, AC220V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 736 | ||
43,426,103 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 7-layer | How to take out lead wire, flashing type connection plug (with 0.3 m lead wire) | NBR material | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 736 | ||
49,823,306 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 7-layer | How to take out lead wire, flashing type connection plug (with 0.3 m lead wire) | EPDM material sealing | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 736 | ||
55,722,277 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 7-layer | How to take out lead wire, flashing type connection plug (with 0.3 m lead wire) | VITON material sealing | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 736 | ||
43,506,598 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 7-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | NBR material | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 736 | ||
54,461,075 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 7-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 736 | ||
60,360,047 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 7-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 736 | ||
43,229,328 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 7-layer | How to take out lead wire, DIN type superconducting (without lead wire) | NBR material | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 736 | ||
54,183,806 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 7-layer | How to take out lead wire, DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 736 | ||
60,082,777 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 7-layer | How to take out lead wire, DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, DC24V | Vacuum Release Control Valve, DC24V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 736 | ||
49,235,626 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 8-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | NBR material | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 773 | ||
61,754,971 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 8-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 773 | ||
68,496,071 VND | 1 Piece(s) | 10 Day(s) | 35 Nl/min/(1stack) | 8-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, AC110V | Vacuum Release Control Valve, AC110V | 35 | 60~65 dBA | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | >8~12 | 773 |
Loading...Tải…
Operating Environment | Standard | Operating Temperature(℃) | -20~80 | Supply air pressure | 4~6 bar, max 7 bar |
---|---|---|---|---|---|
Mounting hole size | 2 - Ø5 | Minimum Hose Internal Diameter (within 2 m)(Vacuum) | >2.5 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy