(!)Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site.Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
[Thông báo] Cập nhật địa chỉ kho tập kết hàng hóa tại khu vực miền Nam của MISUMI Việt Nam. Xem chi tiết.
[Announcement] Update on warehouse address in the Southern region of MISUIMI Vietnam. See more.
[Cảnh Báo] Thủ Đoạn Lừa Đảo Từ Nhân Viên Giao Hàng – Yêu Cầu Trả Phí Ship. Xem chi tiết.
[Warning] Fraud Calling from Shipper - Asking to Pay Shipping Fee. See more.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement. Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
OMRON offers products Electrical Enclosure Cooling Fans specified by Properties Quiet from Electrical & Controls product category. There are a total of 2 items. Parts and equipment for controlling machines and electrical systems. Controllers and power supplies. OMRON products are available to order through MISUMI online 24/7. Free shipping, no minimum order.
[Features]· Axial fan that achieves optimum cooling with a wide variety of options.· Designed for low noise, long life, and weather resistance.· Highly reliable ball bearings are used as bearings.· Product assortment includes plastic wing specification 44 and metal wing specification 28 series.· Product assortment includes the water-resistant AC axial fan-shaped R87T-AA15H-WR (protective structure IPX7).▪ Conforms to CE standards, and certified under UL standards and CSA standards.
Type
Input Voltage
Size
Thickness
Properties
Sensor output
Representative Standard
Maximum Air Flow (AC Input Voltage, when 50 Hz)(m3/min)
Maximum Air Flow (AC Input Voltage, when 60Hz)(m3/min)
Maximum air flow (DC input voltage)(m3/min)
Volume (DC input voltage)(dB)
Volume (AC input voltage, 50 Hz)(dB)
Volume (AC input voltage, 60Hz)(dB)
Maximum Static Pressure (AC Input Voltage, 50 Hz)(Pa)
Maximum Static Pressure (AC Input Voltage, 60Hz)(Pa)
Maximum static pressure (DC input voltage)(Pa)
AC fan
AC100V / AC200V / Other
80x80 / 92x92 / 120x120 / Other
25mm / 38mm / 40 mm or more
Quiet
NA
PSE / CE / UL / CSA
0.4 ~ 5
0.5 ~ 5.8
-
-
26 ~ 56
29 ~ 58
19.5 ~ 118
23.5 ~ 107
-
From:
538,000 VND
Special Price
Days to Ship: Số ngày giao hàng:
Same day or more
Same day or more
You can add up to 6 items per a category to the compare list.
[Features]· Simple "single action" mount axial flow fan unit.▪ Wide array of options, including single, double, and triple fans.· Since the mounting hole is square, and the hole machining surface is hidden, machining can be easily.· Equipped with accessories with selectable up/down orientation (useful in narrow spaces) for opening and shutting the cover (finger guard, filters, plug cord, mounting screws).· Replacement filters and attachments for intake and exhaust ports are available as options.· A complete lineup of single, double, and triple fans, with 8 plastic wing and 8 metal wing models.
Type
Input Voltage
Size
Thickness
Properties
Sensor output
Representative Standard
Maximum Air Flow (AC Input Voltage, when 50 Hz)(m3/min)
Maximum Air Flow (AC Input Voltage, when 60Hz)(m3/min)
Maximum air flow (DC input voltage)(m3/min)
Volume (DC input voltage)(dB)
Volume (AC input voltage, 50 Hz)(dB)
Volume (AC input voltage, 60Hz)(dB)
Maximum Static Pressure (AC Input Voltage, 50 Hz)(Pa)
Maximum Static Pressure (AC Input Voltage, 60Hz)(Pa)
Maximum static pressure (DC input voltage)(Pa)
AC fan
AC100V / AC200V / Other
80x80 / 120x120
25mm / 38mm
Quiet
NA
PSE / CE / UL
0.5 ~ 2.7
0.6 ~ 3.2
-
-
32 ~ 42
34 ~ 46
20 ~ 75
24 ~ 80
-
From:
2,172,480 VND
Days to Ship: Số ngày giao hàng:
Same day or more
Same day or more
BrandNhãn hiệu
Product SeriesDòng sản phẩm
From
Days to ShipSố ngày giao hàng
Type
Input Voltage
Size
Thickness
Properties
Sensor output
Representative Standard
Maximum Air Flow (AC Input Voltage, when 50 Hz)(m3/min)
Maximum Air Flow (AC Input Voltage, when 60Hz)(m3/min)
Maximum air flow (DC input voltage)(m3/min)
Volume (DC input voltage)(dB)
Volume (AC input voltage, 50 Hz)(dB)
Volume (AC input voltage, 60Hz)(dB)
Maximum Static Pressure (AC Input Voltage, 50 Hz)(Pa)
Maximum Static Pressure (AC Input Voltage, 60Hz)(Pa)
Maximum static pressure (DC input voltage)(Pa)
You can add up to 6 items per a category to the compare list.
You can add up to 6 items per a category to the compare list.
Question: What distinguishes an industrial fan from a standard equipment fan, and what applications are they used for?
Answer:
Items
Industrial Fan
Standard Equipment Fan
Design and Construction
Robust, heavy-duty materials
Compact, designed for power supply units
Size
Larger sizes
Varied sizes
Performance
High airflow capacity, variable speeds
Efficient cooling for power supplies
Applications
Ventilation, process cooling in industries
Cooling power supply units and electronic equipment
Specialized Types
Centrifugal, axial fans
Designed for power supply applications
Noise Levels
Can be noisy
Designed for quiet operation
In summary, industrial fans excel in heavy-duty ventilation, while standard equipment power supply fans are specialized for cooling power supply units in various electronic equipment, emphasizing compact designs and quieter operation.
Question: How do AC and DC fans differ in functionality, and which is more suitable for electrical control systems?
Answer: AC and DC fans differ in their motor type and power source. AC fans use alternating current motors, while DC fans use direct current motors. AC fans are more common and less expensive, but they are also less energy efficient than DC fans. DC fans can be controlled more precisely, making them a better choice for applications where consistent airflow is crucial. Additionally, DC fans can handle lower voltage and can be used in a wider range of applications.
In terms of suitability for electrical control systems, DC fans are generally more suitable. This is because they offer greater controllability, energy efficiency, and compatibility with a wider range of control systems. DC fans are often used in applications such as CNC machines, robotics, and industrial automation.
Question: Can you explain how cooling fans contribute to the maintenance and performance of machinery?
Answer: Cooling fans play a vital role in maintaining the performance and extending the lifespan of machinery by effectively removing excess heat generated during operation. Overheating can lead to component damage, reduced efficiency, and premature equipment failure. Cooling fans actively circulate air around the machinery, dissipating heat and preventing overheating. This consistent cooling helps maintain optimal operating temperatures, ensuring smooth operation, consistent performance, and reduced wear and tear.
Question: What are the benefits of using energy-efficient cooling solutions for industrial equipment, and what options does MISUMI Thailand offer?
Answer: Implementing energy-efficient cooling solutions for industrial equipment offers a multitude of benefits, including:
1.Reduced Energy Consumption: Significant energy savings, lowering operational costs and environmental impact.
2.Extended Equipment Lifespan: Reduced wear and tear, minimizing downtime and maintenance expenses.
3.Improved Process Efficiency: Optimized cooling ensures consistent performance and product quality.
4.Enhanced Safety: Reduced risk of overheating and potential hazards.
MISUMI Thailand provides a comprehensive range of energy-efficient cooling solutions for industrial equipment, including High-efficiency Fans. which Low-energy consumption fans with optimized airflow for various applications.
Question: In what ways are waterproof and oilproof fans critical to the operations of industrial environments?
Answer: Waterproof and oilproof fans play a crucial role in industrial settings due to their ability to withstand harsh environmental conditions and maintain optimal performance. These fans are essential for applications involving water exposure, dust, and airborne contaminants, ensuring proper ventilation and temperature control in various industrial environments, including manufacturing plants, power plants, and chemical processing facilities.
Question: How has technology advanced the control and efficiency of electric fans used in mechanical ventilation?
Answer: Technology has revolutionized the control and efficiency of electric cooling fans in mechanical ventilation systems, leading to more intelligent, adaptable, and energy-efficient systems. These advancements encompass various aspects, including smart sensors, Variable Frequency Drives (VFDs), improved blade designs, energy-efficient motors, remote monitoring, and Artificial Intelligence (AI) integration.
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy