(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Brand |
|
---|---|
CAD |
|
Days to Ship |
|
4 itemsMặt hàng
You can add up to 6 items per a category to the compare list.
Direct Piping3GA1/2/3R and 4GA1/2/3R Series Unit Valve
CKD
The new 3GA1/2/3R, 4GA1/2/3R series have inherited the legacy 3G/4G series concept and evolved it further.[Environmental Performance]· Continuous power OK (single solenoid type). Uses a new coil actuator.· Reduced power consumption.[Safety]· Manual misoperation prevention (manual device has a protective cover).· Suppresses malfunctioning problems (metal base, exhaust malfunction prevention valve regardless of resin block come as standard).· Foreign matter problem prevention[Reliability]· Low sliding · Realizes long life· Improved leave response[Ease of use]· Wiring connector horizontal sharing· Uses rotary connector
Number of Ports | Application | Switching Type | Voltage | Number of Solenoids | Mounting Orientation | Pipe Port Type | Specifications | Status at Power Off | Plumbing Thread Nominal | Plumbing | Applicable Cylinder Dia.(Ø) | Type | Driving Type | Connecting Tube Diameter | Pressure Rating(MPa) | Seal Type | CV Value | Pilot Air Supply |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
3-Port Valve | Single Use | 2-Position Normally Closed | DC3V | Single | Direct | Rc (R) / NPT / G / One-Touch Plumbing | Standard / Lubrication Free | Self-Recovery (Pressure Differential Return) | 1/8 | Direct Plumbing | 40 to 80 | Solenoid Valves | Pilot Type Spool | Ø4 / Ø6 / Ø8 / Ø1/4 / Ø5/16 | - | Soft Seal | - | - |
Days to Ship: Số ngày giao hàng: 21 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Individual wiring manifold M3/4GA1/2/3R-(D) series single unit
CKD
The new M3/4GA1/2/3R-(D) series have inherited the legacy 3G/4G series concept and evolved it further.[Environmental Performance]· Continuous power OK (single solenoid type). Uses a new coil actuator.· Reduced power consumption.[Safety]· Manual misoperation prevention (manual device has a protective cover).· Suppresses malfunctioning problems (metal base, exhaust malfunction prevention valve regardless of resin block come as standard).· Foreign matter problem prevention[Reliability]· Low sliding · Realizes long life· Improved leave response[Ease of use]· Wiring connector horizontal sharing· Uses rotary connector
Number of Ports | Application | Switching Type | Voltage | Number of Solenoids | Mounting Orientation | Pipe Port Type | Specifications | Status at Power Off | Plumbing Thread Nominal | Plumbing | Applicable Cylinder Dia.(Ø) | Type | Driving Type | Connecting Tube Diameter | Pressure Rating(MPa) | Seal Type | CV Value | Pilot Air Supply |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
3-Port Valve | Single Use | 2-Position Normally Closed | DC3V | Single | Manifold Base | One-Touch Plumbing | Standard / Lubrication Free | Self-Recovery (Pressure Differential Return) | - | Direct Plumbing | 20 to 40 | Solenoid Valves | Pilot Type Spool | Ø4 | - | Soft Seal | - | - |
Days to Ship: Số ngày giao hàng: 13 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Individual wiring manifold M3GB1· 2/M4GB1-3R-(D) series single unit
CKD
The new M3GB1/2/M4GB1 to 3R-(D) series have inherited the legacy 3G/4G series concept and evolved it further.[Environmental Performance]· Continuous power OK (single solenoid type). Uses a new coil actuator.· Reduced power consumption.[Safety]· Manual misoperation prevention (manual device has a protective cover).· Suppresses malfunctioning problems (metal base, exhaust malfunction prevention valve regardless of resin block come as standard).· Foreign matter problem prevention[Reliability]· Low sliding · Realizes long life· Improved leave response[Ease of use]· Wiring connector horizontal sharing· Uses rotary connector
Number of Ports | Application | Switching Type | Voltage | Number of Solenoids | Mounting Orientation | Pipe Port Type | Specifications | Status at Power Off | Plumbing Thread Nominal | Plumbing | Applicable Cylinder Dia.(Ø) | Type | Driving Type | Connecting Tube Diameter | Pressure Rating(MPa) | Seal Type | CV Value | Pilot Air Supply |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
5-Port Valve | Unit for Manifold Mounting | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center | DC3V | Single / Double | Manifold Base | Others | Standard / Lubrication Free | Self-Retaining / Self-Recovery (Spring Return) / Self-Recovery (Pressure Differential Return) | - | Sub-Base Plumbing | 20 to 40 ~ 63 to 100 | Solenoid Valves | Pilot Type Spool | - | - | Soft Seal | - | - |
Days to Ship: Số ngày giao hàng: 14 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Base Pipe 3GB1: 2R Series, 4GB1: 2/3R Series, Single Valve
CKD
The new 3GB1/2R, 4GB1/2/3R series have inherited the legacy 3G/4G series concept and evolved it further.[Environmental Performance]· Continuous power OK (single solenoid type). Uses a new coil actuator.· Reduced power consumption.[Safety]· Manual misoperation prevention (manual device has a protective cover).· Suppresses malfunctioning problems (metal base, exhaust malfunction prevention valve regardless of resin block come as standard).· Foreign matter problem prevention[Reliability]· Low sliding · Realizes long life· Improved leave response[Ease of use]· Wiring connector horizontal sharing· Uses rotary connector
Number of Ports | Application | Switching Type | Voltage | Number of Solenoids | Mounting Orientation | Pipe Port Type | Specifications | Status at Power Off | Plumbing Thread Nominal | Plumbing | Applicable Cylinder Dia.(Ø) | Type | Driving Type | Connecting Tube Diameter | Pressure Rating(MPa) | Seal Type | CV Value | Pilot Air Supply |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
5-Port Valve | Single Use | 2-Position Exhaust / 3-Position Pressure Center | DC3V | Double | Manifold Base | Rc (R) / NPT / G | Standard / Lubrication Free | Self-Retaining / Self-Recovery (Spring Return) | 1/4 ~ 3/8 | Sub-Base Plumbing | 40 to 80 ~ 63 to 100 | Solenoid Valves | Pilot Type Spool | - | - | Soft Seal | - | - |
Days to Ship: Số ngày giao hàng: 61 Day(s) or more |
BrandNhãn hiệu |
---|
Product SeriesDòng sản phẩm |
From |
Days to ShipSố ngày giao hàng |
Number of Ports |
Application |
Switching Type |
Voltage |
Number of Solenoids |
Mounting Orientation |
Pipe Port Type |
Specifications |
Status at Power Off |
Plumbing Thread Nominal |
Plumbing |
Applicable Cylinder Dia.(Ø) |
Type |
Driving Type |
Connecting Tube Diameter |
Pressure Rating(MPa) |
Seal Type |
CV Value |
Pilot Air Supply |
You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | |
BrandNhãn hiệu | CKD | CKD | CKD | CKD |
Product SeriesDòng sản phẩm | Individual wiring manifold M3/4GA1/2/3R-(D) series single unit | Individual wiring manifold M3GB1· 2/M4GB1-3R-(D) series single unit | ||
From | - | - | - | - |
Days to ShipSố ngày giao hàng | 21 Day(s) or more | 13 Day(s) or more | 14 Day(s) or more | 61 Day(s) or more |
Number of Ports | 3-Port Valve | 3-Port Valve | 5-Port Valve | 5-Port Valve |
Application | Single Use | Single Use | Unit for Manifold Mounting | Single Use |
Switching Type | 2-Position Normally Closed | 2-Position Normally Closed | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center | 2-Position Exhaust / 3-Position Pressure Center |
Voltage | DC3V | DC3V | DC3V | DC3V |
Number of Solenoids | Single | Single | Single / Double | Double |
Mounting Orientation | Direct | Manifold Base | Manifold Base | Manifold Base |
Pipe Port Type | Rc (R) / NPT / G / One-Touch Plumbing | One-Touch Plumbing | Others | Rc (R) / NPT / G |
Specifications | Standard / Lubrication Free | Standard / Lubrication Free | Standard / Lubrication Free | Standard / Lubrication Free |
Status at Power Off | Self-Recovery (Pressure Differential Return) | Self-Recovery (Pressure Differential Return) | Self-Retaining / Self-Recovery (Spring Return) / Self-Recovery (Pressure Differential Return) | Self-Retaining / Self-Recovery (Spring Return) |
Plumbing Thread Nominal | 1/8 | - | - | 1/4 ~ 3/8 |
Plumbing | Direct Plumbing | Direct Plumbing | Sub-Base Plumbing | Sub-Base Plumbing |
Applicable Cylinder Dia.(Ø) | 40 to 80 | 20 to 40 | 20 to 40 ~ 63 to 100 | 40 to 80 ~ 63 to 100 |
Type | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves |
Driving Type | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool |
Connecting Tube Diameter | Ø4 / Ø6 / Ø8 / Ø1/4 / Ø5/16 | Ø4 | - | - |
Pressure Rating(MPa) | - | - | - | - |
Seal Type | Soft Seal | Soft Seal | Soft Seal | Soft Seal |
CV Value | - | - | - | - |
Pilot Air Supply | - | - | - | - |
Loading...Tải…
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy