(!)Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site.Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 8:00 15/12/2024 to 5:00 (ICT) 16/12/2024. We apologize for the inconvenience.
[Thông báo] Cập nhật địa chỉ kho tập kết hàng hóa tại khu vực miền Nam của MISUMI Việt Nam. Xem chi tiết.
[Announcement] Update on warehouse address in the Southern region of MISUIMI Vietnam. See more.
[Cảnh Báo] Thủ Đoạn Lừa Đảo Từ Nhân Viên Giao Hàng – Yêu Cầu Trả Phí Ship. Xem chi tiết.
[Warning] Fraud Calling from Shipper - Asking to Pay Shipping Fee. See more.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement. Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
A crimp terminal is a connection part used by attaching to the end of a cable. There are various types such as bare crimp terminals,insulated crimp terminals, plug-in crimp terminals, etc. The main shapes are round, Y-type, sleeve-ring type, blade type, etc. There are two types: crimping using a dedicated tool, and connecting to the terminal block by insertion., therefore select the type according to the application and connection target. The structure and characteristics of the crimp terminals differ depending on the product, and there are various products available such as those with heat resistance that can be used for heater wires and heating wires, those that have guides that allow the cable to be inserted smoothly into the cylinder, those that are tin-plated and corrosion-resistant, etc. It is widely used for applications that require mating, such as internal wiring of industrial equipment, measuring instrument, FA control equipment, etc., connection between equipment, various electrical work, etc.
[Features]· Optimal for transition wiring, etc. Prevents core wires from becoming loose. Inserts into single-wire compatible terminal blocks, improving reliability. Can simultaneously crimp two wires. The insulation sleeves are color coded, making it easy to distinguish wires by size.
Shape
Conforming wire size(AWG)
Internal Diameter(φ)
Type
Outer Diameter(mm)
Series
Insulation coating (color)
Insulation material
Overall Length(mm)
Features
Representative Standard
Other
2x14
2.9
Crimp Terminal With Insulation
3.3
-
Blue
Other
18.5
-
UL / CSA
From:
19,270 VND
Days to Ship: Số ngày giao hàng:
4 Day(s) or more
4 Day(s) or more
BrandNhãn hiệu
Product SeriesDòng sản phẩm
From
Days to ShipSố ngày giao hàng
Shape
Conforming wire size(AWG)
Internal Diameter(φ)
Type
Outer Diameter(mm)
Series
Insulation coating (color)
Insulation material
Overall Length(mm)
Features
Representative Standard
You can add up to 6 items per a category to the compare list.
Question: Wire crimping and Soldering. Which one is better?
Answer: Wire crimping” has pros in that it is easy to install, the electricity can flow smoothly, and it can be used with various equipments. But the cons are that it costs money due to the tools used in the process. On the other hand, “Soldering” uses Flux to make electrical contact, which is cheaper than wire crimping. But the wire and contact point have less flexibility. If you use soldering in equipment that causes vibration, there is a risk of broken wires.
Question: How many Wires can crimp together?
Answer: It is not recommended for pair multiple wires in one crimp terminal when wire crimping. Because crimp terminals are designed to work with a specific size of wire, when multiple wires are combined in one crimp, the holding force is reduced, resulting in heat at the terminal.
Question: Should you twist the wire before crimping?
Answer: If stranded wire is used in wire crimping, The twisted method of copper wire before wire crimping will increase the surface density. The chance that a wire terminal will be loose or fall out after crimping is going to be reduced. and the risk of an electrical accident is also decreased.
Question: Can you use plier for wire crimping?
Answer: It is not recommended to use pliers to crimp the wire except “Wire Crimper”. because there is a chance that the wire terminal will be loose or damaged, which is called “Bad Contact”. And when the equipment is running, the heat at the terminal is going to increase more than usual because electricity cannot flow smoothly. It will cause the ark to and melted wires. Therefore, should study how to use the crimping pliers properly to prevent the danger that may occur.
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy