(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.

  • Viewed
    Products
    Sản phẩm
    đã xem
    최근 본
    상품
    查看产品 查看產品
  • My
    Components
    Linh kiện
    của tôi
    나의 부품 我的部件 我的部件
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • [Thông báo] Cập nhật địa chỉ kho tập kết hàng hóa tại khu vực miền Nam của MISUMI Việt Nam. Xem chi tiết.
    [Announcement] Update on warehouse address in the Southern region of MISUIMI Vietnam. See more. 
  • [Cảnh Báo] Thủ Đoạn Lừa Đảo Từ Nhân Viên Giao Hàng – Yêu Cầu Trả Phí Ship. Xem chi tiết.
    [Warning] Fraud Calling from Shipper - Asking to Pay Shipping Fee. See more.

Overload Relays(Motor Capacity VAC 200–220 Class:1/5)

A thermal relay is a type of relay that protects a motor from overcurrent. It is called "thermal relay" because it operates after detecting a rise in the temperature of the motor coil. In some designs, the terminals are equipped with a cover to improve safety by protecting against electric shocks during maintenance or inspection. Most thermal relays are composed of a heater element and bi-metal section. When current flows through the heater element, the bi-metal section bends and the contacts open. If the relay is activated, eliminate the cause before restarting operation. Types include an automatic type that resets automatically after activation, and a manual type where the user resets the relay by pressing a button after the bi-metal has cooled. Because a thermal relay itself does not have a shut-off function, it is usually used in combination with an electromagnetic contactor.
CAD
Days to Ship
  • All
  • 4 Day(s) or Less
  • 14 Day(s) or Less
  • 30 Day(s) or Less

1 itemsMặt hàng

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    Thermal Relay

    Thermal Relay

    MISUMI

    A low cost thermal relay. Accessories can be easily installed.

    • Volume Discount
    • CE-Compliant
    • VDE
    • BS
    • IEC
    CAD :
    2D
    Motor capacity 400 to 440-VAC class(kW/A) Motor Capacity VAC 200–220 Class(kW/A) Coil rated voltage(V) Number of Poles Auxiliary Contact Representative Standard Dimension length(mm) Dimension width(mm) Dimension thickness(mm)
    - 1/5 - 3 1a1b CE 73.2 ~ 74.6 45 63.7 ~ 90
    From: 340,470 VND
    Days to Ship: Số ngày giao hàng: 4 Day(s) or more
    day to ship 4 Day(s) or more
BrandNhãn hiệu
Product SeriesDòng sản phẩm
CADCAD
From
Days to ShipSố ngày giao hàng
SpecificationsĐặc điểm kĩ thuật
Motor capacity 400 to 440-VAC class(kW/A)
Motor Capacity VAC 200–220 Class(kW/A)
Coil rated voltage(V)
Number of Poles
Auxiliary Contact
Representative Standard
Dimension length(mm)
Dimension width(mm)
Dimension thickness(mm)

    You can add up to 6 items per a category to the compare list.

    Thermal Relay
      BrandNhãn hiệu

      MISUMI

      Product SeriesDòng sản phẩm

      Thermal Relay

      CADCAD
      • 2D
      From

      340,470 VND

      Days to ShipSố ngày giao hàng 4 Day(s) or more
      SpecificationsĐặc điểm kĩ thuật
      • CE-Compliant
      • VDE
      • BS
      • IEC
      Motor capacity 400 to 440-VAC class(kW/A)-
      Motor Capacity VAC 200–220 Class(kW/A)1/5
      Coil rated voltage(V)-
      Number of Poles3
      Auxiliary Contact1a1b
      Representative StandardCE
      Dimension length(mm)73.2 ~ 74.6
      Dimension width(mm)45
      Dimension thickness(mm)63.7 ~ 90

      Loading...Tải…

      1. 1

      Related Categories to Overload RelaysDanh mục liên quan đến Overload Relays

      FAQ Overload Relays

      Question: What is the purpose of terminals 95 and 96 on an overload relay?
      Answer: In electrical systems, terminals 95 and 96 on an overload relay serve a crucial role in motor protection. Terminal 95 is the common terminal for the trip circuit, and terminal 96 is the normally close contact. When the overload relay detects excessive current in a motor, it activates the trip circuit. This action causes the normally close contact at terminal 96 to open, initiating protective measures, such as disconnecting the motor from the power supply, to prevent damage due to overcurrent.
      Question: How do overload relays contribute to electrical safety?
      Answer: Overload relays enhance electrical safety by monitoring motor currents. If currents exceed safe levels, the relay triggers protective actions, preventing motor overheating and potential fire hazards. By swiftly disconnecting power during overloads, they safeguard equipment, reduce downtime, and comply with safety standards. Overload relays offer early warnings of issues, allowing for timely maintenance. Customizable to specific current limits, they contribute to adaptability and seamless integration with control systems, ensuring efficient protection and reliable operation in various electrical applications.
      Question: What factors determine the correct setting for an overload relay?
      Answer: The correct overload relay setting depends on factors such as motor rating, type, and efficiency. Considerations include inrush current during startup, operating conditions, and load variations. Crucial aspects involve service factors, thermal models, and adherence to standards. Following manufacturer recommendations, finding a balance between protection sensitivity and avoiding unnecessary tripping is key. Regular reviews accommodate changes in the electrical system or equipment, ensuring optimal protection, compliance with standards, and reliability across various applications.
      Question: What role does an overload relay play in a 3-phase system?
      Answer: In a 3-phase system, an overload relay protects electric motors by monitoring current. When it detects excess current, signaling an overload, the relay activates a trip circuit that rapidly disconnects the motor. This prevents overheating, safeguarding the motor from damage and mitigating fire hazards. The overload relay contributes to overall system reliability, with adjustable settings and integration capabilities enhancing its adaptability and automation in motor protection.
      Question: How can the principle of overload be beneficial in relay design?
      Answer: The principle of overload in relay design is pivotal for electrical system safety. Overload relays, responsive to excessive current, disconnect power swiftly, preventing equipment damage and fire hazards. Adjustable settings accommodate diverse motor requirements, ensuring adaptability. Early warning features facilitate timely maintenance, minimizing downtime. This principle aligns with safety standards, promoting compliance. Beyond protection, overload relays contribute to energy efficiency by optimizing motor performance under varying loads. Overall, they play a crucial role in enhancing equipment longevity, system reliability, and adherence to safety regulations in electrical systems.
      Question: What distinguishes bimetallic overload relays from electronic types?
      Answer: Bimetallic and electronic overload relays differ in technology and performance. Bimetallic relays use physical expansion of bimetallic strips for current detection, providing simplicity but less precision. Electronic relays, employing sensors and microprocessors, offer higher sensitivity, adjustability, and advanced motor protection. While bimetallic relays are cost-effective for basic applications, electronic relays excel in complex systems, delivering enhanced performance, adaptability, and reliability. The choice depends on the application's needs, with bimetallic relays suited for simplicity and electronic relays for advanced functionality.