(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Set of 6 standard outer micrometers from 0 to 150 mm convenient for collective management.
[Features]
· Heat-proof specifications help prevent transfer of worker's body temperature.
· In a dedicated wooden box for convenient storage.
· Includes 5 reference rods. (Excluding MC105-25)
· Measurement surface has a carbide tip.
· Equipped with constant pressure device.
· The frame has a painted finish.
[Applications]
· Can be used for measurement of external dimensions.
• Standard micro meter For outside measurement. | • U shape steel plate micro meter For measuring steel plate thickness. |
• Spline micro meter To conveniently measure groove of spline shaft. | • Disk micro meter Disk shape gauge head is perfect for measuring root tangent length of gears. |
• Blade micro meter Measuring surface is blade type, perfect for measuring groove diameter of shaft,etc. | • Spherical face micro meter Anvil side of gauge head is spherical shape, perfect for measuring wall thickness of pipe. |
• Point micro meter Perfect for measuring the thickness of frill's web, etc. |
• Examples of reading graduation | |
*Usaually, the left picture's reading value up to 0.01mm, lower picture's reading value measure with eyes up to 0.001 (1μm). | |
Reading value for sleeve is 7.0mm, reading value for thimble is 0.37mm and measured value is 7.37mm. |
01 Cleaning measuring surface To keep the measuring surface of anvil and spindle clean, gently clip a clean paper between the two measuring surfaces, then let loose of the spindle to remove the paper. *Dust is easily attracted to certain types of paper, do not force the paper out. | ||
02 Turning ratchet To adjust measuring pressure is very important. Idling turn the ratchet stopper 1~3 times. | ||
03 Correcting clamp In the picture, graduation of 0 has about 5μm deviation and it needs to be corrected. Clamp is used to set spindle into correct location. | ||
04 Put in key-spanner The sleeve on the back of the clamp has a hole. Put key-spanner into the hole and adjust to 0. If spanner is not correctly put in, it will loosen the spanner and break graduation, please be careful. | ||
05 0 position This is on the accurate 0 positions. When reading graduation, eyes should look directly at graduation. 2~3μm error will occur if it's not read directly. | ||
06 Confirm accuracy (Use micro meter stand) *Due to turn by screw , error will occur on screw's pitch, needs to make sure it's on 0 position. Hold micro meter with micro meter stand. | ||
07 Confirm accuracy (Clip block gauge on) To click block gauge on, make sure dimension and block gauge and graduation on micro meter is the same. | ||
Part Number |
---|
MC105-150ST |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng |
---|---|---|---|---|
12,813,063 VND | 1 Piece(s) | 9 Day(s) or more |
Loading...Tải…
Type | Standard Micrometer | Display Method | Analog | Maximum Measuring Length (Adjustment Range)(mm) | 101 ~ 200 |
---|---|---|---|---|---|
Waterproof Function | Not Included | With / Without Measurement Data Output Terminal | Not Included | Measuring Range(mm) | 0–150 |
Stem Shape | Stem w/ Nut, w/ Clamp | Overall length L(mm) | 121 | Minimum Scale(mm) | 0.01 |
Maximum Tolerance(µm) | 3 | Mass(g) | 120 | Constant Pressure Device | Available |
Tip shape | Plane | Spindle(mm) | φ6.5×27 | Stem(mm) | φ10×15 |
Nut Diameter(mm) | 14×4 | Thimble Diameter(mm) | 18 | Maximum Permissible Error(µm) | 4–6 |
Outside Micrometer | 0-25, 25-50, 50-75, 75-100, 100-125, 125-150 (6 units) | Reference Bar | 25,50,75,100,125 (5 Units) | Minimum Reading(mm) | 0.01 |
Please check the type/dimensions/specifications of the part MC105-150ST in the Standard Outer Micrometer Set series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần MC105-150ST trong chuỗi Standard Outer Micrometer Set.
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy