(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Format FR-HAL-[][] | 200 V | 400 V |
0.4K to 110K *1 | H0.4K to H560K *1 | |
Power factor improvement effect *2 | Power supply factor: approx. 88% (92.3%*3) at 100% load | |
Vibration | 5.9 m/s2 or less, 10 to 55 Hz (directions of X, Y, Z axes) | H110K or lower: 5.9 m/s2 or less H185K or higher: 2.9 m/s2 or less, 10 to 55 Hz (directions of X, Y, Z axes) |
Mounting Method | (H)55K or lower: Mount horizontally or vertically (H)75K or higher: Mount horizontally |
*1 See Format in Outline Drawing for capacity details.
*2 The power factor value assumes a power supply impedance of 1%. The power supply capacity value varies depending on the power supply impedance.
The load applies to a basic wave current of 100%, based on the JEM-TR201 standard. The power factor improvement effect will be slightly lower if using a motor of 0.4 kW or less.
*3 The power factor improvement effect is approx. 88% (92.3% when calculated assuming that the power factor of a basic wave is 1, based on the 2013 edition of the Public Building Construction Standard Specifications [Electrical Facilities Construction Edition] compiled by the Ministry of Land, Infrastructure, Transport and Tourism).
• This is a representative drawing of the external appearance. The actual external appearance will differ depending on the format.
& bull; W1 and D1 indicate the mounting hole pitch. D indicates the mounting hole size.
& bull; As the reactor itself will generate heat, be sure to secure sufficient space around the reactor.
(At least 10 cm above and below, and at least 5 cm on either side, regardless of the reactor mounting orientation)
Format | W | W1 | H | D | D1 | d | Weight (kg) | |
200 V | 0.4K | 104 | 84 | 99 | 72 | 40 | M5 | 0.6 |
0.75K | 104 | 84 | 99 | 74 | 44 | M5 | 0.8 | |
1.5K | 104 | 84 | 99 | 77 | 50 | M5 | 1.1 | |
2.2K | 115 | 40 | 115 | 77 | 57 | M6 | 1.5 | |
5.5K | 115 | 40 | 115 | 83 | 67 | M6 | 2.3 | |
7.5K | 130 | 50 | 135 | 100 | 86 | M6 | 4.2 | |
11K | 160 | 75 | 164 | 111 | 92 | M6 | 5.2 | |
15K | 160 | 75 | 167 | 126 | 107 | M6 | 7 | |
18.5K | 160 | 75 | 128 | 175 | 107 | M6 | 7.1 | |
22K | 185 | 75 | 150 | 158 | 87 | M6 | 9 | |
30K | 185 | 75 | 150 | 168 | 87 | M6 | 9.7 | |
37K | 210 | 75 | 175 | 174 | 82 | M6 | 12.9 | |
55K | 210 | 75 | 175 | 201 | 97 | M6 | 17.4 | |
75K | 240 | 150 | 210 | 213 | 109 | M8 | 23 | |
110K | 330 | 170 | 325 | 258 | 127 | M10 | 40 |
Format | W | W1 | H | D | D1 | d | Weight (kg) | |
400 V | H0.4K | 135 | 120 | 115 | 59.6 | 45 | M4 | 1.5 |
H1.5K | 135 | 120 | 115 | 59.6 | 45 | M4 | 1.5 | |
H2.2K | 135 | 120 | 115 | 59.6 | 45 | M4 | 1.5 | |
H3.7K | 135 | 120 | 115 | 70.6 | 57 | M4 | 2.5 | |
H5.5K | 160 | 145 | 142 | 72 | 55 | M4 | 3.5 | |
H7.5K | 160 | 145 | 142 | 91 | 75 | M4 | 5 | |
H11K | 160 | 145 | 146 | 91 | 75 | M4 | 6 | |
H15K | 220 | 200 | 195 | 105 | 70 | M5 | 9 | |
H18.5K | 220 | 200 | 215 | 170 | 70 | M5 | 9 | |
H22K | 220 | 200 | 215 | 170 | 70 | M5 | 9.5 | |
H30K | 220 | 200 | 215 | 170 | 75 | M5 | 11 | |
H37K | 220 | 200 | 214 | 170 | 100 | M5 | 12.5 | |
H45K | 280 | 255 | 245 | 165 | 80 | M6 | 15 | |
H55K | 280 | 255 | 245 | 170 | 90 | M6 | 18 | |
H110K | 240 | 150 | 225 | 220 | 99 | M8 | 28 | |
H185K | 330 | 170 | 325 | 270 | 142 | M10 | 55 | |
H280K | 330 | 170 | 325 | 320 | 192 | M10 | 80 | |
H355K | 330 | 170 | 325 | 340 | 192 | M10 | 80 |
Format FR-HEL-[][] | 200 V | 400 V |
0.4K to 110K *1 | H0.4K to H355K *1 | |
Power factor improvement effect *2 | Power supply factor: approx. 93% (94.4% *3) | |
Vibration | 5.9 m/s2 or less, 10 to 55 Hz (directions of X, Y, Z axes) | |
Mounting Method | Mount horizontally or vertically |
*1 See Format in Outline Drawing for capacity details.
*2 The power factor value assumes a power supply impedance of 1%. The power supply capacity value varies depending on the power supply impedance.
The load applies to a basic wave current of 100%, based on the JEM-TR201 standard. The power factor improvement effect will be slightly lower if using a motor of 0.4 kW or less.
*3 The power factor improvement effect is approx. 93% (94.4% when calculated assuming that the power factor of a basic wave is 1, based on the 2013 edition of the Public Building Construction Standard Specifications [Electrical Facilities Construction Edition] compiled by the Ministry of Land, Infrastructure, Transport and Tourism).
• This is a representative drawing of the external appearance. The actual external appearance will differ depending on the format.
& bull; W1 and D1 indicate the mounting hole pitch. D indicates the mounting hole size.
& bull; As the reactor itself will generate heat, be sure to secure sufficient space around the reactor.
(At least 10 cm above and below, and at least 5 cm on either side, regardless of the reactor mounting orientation)
Format | W | W1 | H | D | D1 | d | Weight (kg) | |
200 V | 2.2K | 85 | 74 | 81 | 70 | ─ | M4 | 0.9 |
5.5K | 77 | 55 | 92 | 92 | 67 | M4 | 1.9 | |
11K | 105 | 64 | 133 | 112 | 79 | M6 | 3.3 | |
15K | 105 | 64 | 133 | 115 | 84 | M6 | 4.1 | |
18.5K | 105 | 64 | 93 | 165 | 94 | M6 | 4.7 | |
30K | 114 | 72 | 100 | 200 | 101 | M6 | 7.8 | |
37K | 133 | 86 | 117 | 195 | 98 | M6 | 10 | |
45K | 133 | 86 | 117 | 205 | 108 | M6 | 11 | |
55K | 153 | 126 | 132 | 209 | 122 | M6 | 12.6 | |
75K | 150 | 130 | 190 | 340 | 310 | M6 | 17 | |
90K | 150 | 130 | 200 | 340 | 310 | M6 | 19 | |
110K | 175 | 150 | 200 | 400 | 365 | M8 | 20 |
Format | W | W1 | H | D | D1 | d | Weight (kg) | |
400 V | H0.4K | 90 | 75 | 78 | 60 | ─ | M5 | 0.6 |
H0.75K | 66 | 50 | 100 | 70 | 48 | M4 | 0.8 | |
H5.5K | 96 | 60 | 128 | 100 | 75 | M5 | 3 | |
H11K | 105 | 75 | 137 | 110 | 85 | M5 | 4.5 | |
H18.5K | 114 | 75 | 162 | 120 | 80 | M5 | 5 | |
H22K | 133 | 90 | 178 | 120 | 75 | M5 | 6 | |
H30K | 133 | 90 | 178 | 120 | 80 | M5 | 6.5 | |
H37K | 133 | 90 | 187 | 155 | 100 | M5 | 8.5 | |
H45K | 133 | 90 | 187 | 170 | 110 | M5 | 10 | |
H55K | 152 | 105 | 206 | 170 | 106 | M6 | 11.5 | |
H75K | 140 | 120 | 185 | 320 | 295 | M6 | 16 | |
H90K | 150 | 130 | 190 | 340 | 310 | M6 | 20 | |
H110K | 150 | 130 | 195 | 340 | 310 | M6 | 22 | |
H132K | 175 | 150 | 200 | 405 | 370 | M8 | 26 | |
H160K | 175 | 150 | 205 | 405 | 370 | M8 | 28 | |
H250K | 190 | 165 | 250 | 440 | 400 | M8 | 35 | |
H280K | 190 | 165 | 255 | 440 | 400 | M8 | 38 | |
H315K | 210 | 185 | 250 | 495 | 450 | M10 | 42 | |
H355K | 210 | 185 | 250 | 495 | 450 | M10 | 46 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Type | Voltage class (V) | Applicable inverter capacity (kW) | Width (W) (mm) | Height (H) (mm) | Depth (D) (mm) | Weight (kg) | Protection class | CE Conformity | UL/cUL Conformity | UKCA Conformity | Main function | Rated active power (kW) | Rated power (HP) | Dimension (W) (mm) | Dimension (D) (mm) | Dimension (H) (mm) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
25,921,250 VND | 1 Piece(s) | Quote | AC Reactor | 400 | 110 | - | - | - | - | - | - | - | - | - | - | - | 240 | 220 | 225 | ||
1,198,750 VND | 1 Piece(s) | Quote | DC Reactor | 200 | - | - | - | - | - | - | - | - | - | Filter unit | 1.5 | 2 | - | - | - | ||
1,438,750 VND | 1 Piece(s) | Quote | DC Reactor | 200 | 3.7 | 77 | 92 | 82 | 1.5 | - | - | - | - | - | - | - | - | - | - | ||
15,878,750 VND | 1 Piece(s) | Quote | DC Reactor | 200 | 75 | - | - | - | - | - | - | - | - | - | - | - | 150 | 340 | 190 | ||
18,330,000 VND | 1 Piece(s) | Quote | DC Reactor | 200 | 90 | - | - | - | - | - | - | - | - | - | - | - | 150 | 340 | 200 | ||
20,743,750 VND | 1 Piece(s) | Quote | DC Reactor | 200 | 110 | - | - | - | - | - | - | - | - | - | - | - | 175 | 400 | 200 | ||
1,198,750 VND | 1 Piece(s) | Quote | DC Reactor | 400 | 1.5 | 105 | 152 | 125 | 5 | IP00 | - | - | - | - | - | - | - | - | - | ||
2,098,750 VND | 1 Piece(s) | Quote | DC Reactor | 400 | 7.5 | 120 | 74.7 | 100 | 2.2 | IP20 | Yes | - | - | - | - | - | - | - | - | ||
2,997,500 VND | 1 Piece(s) | Quote | DC Reactor | 400 | - | - | - | - | - | - | - | - | - | Filter unit | 15 | 20 | - | - | - | ||
16,647,500 VND | 1 Piece(s) | Quote | DC Reactor | 400 | 90 | - | - | - | - | - | - | - | - | - | - | - | 150 | 340 | 190 | ||
19,978,750 VND | 1 Piece(s) | Quote | DC Reactor | 400 | 110 | - | - | - | - | - | - | - | - | - | - | - | 150 | 405 | 195 | ||
23,306,250 VND | 1 Piece(s) | Quote | DC Reactor | 400 | 132 | - | - | - | - | - | - | - | - | - | - | - | 175 | 405 | 200 | ||
46,093,750 VND | 1 Piece(s) | Quote | DC Reactor | 400 | 160 | - | - | - | - | - | - | - | - | - | - | - | 175 | 405 | 205 | ||
31,630,000 VND | 1 Piece(s) | Quote | DC Reactor | 400 | 185 | 175 | 405 | 240 | 29 | IP00 | Yes | Yes | Yes | - | - | - | - | - | - | ||
76,823,750 VND | 1 Piece(s) | Quote | DC Reactor | 400 | 250 | - | - | - | - | - | - | - | - | - | - | - | 190 | 440 | 250 | ||
44,950,000 VND | 1 Piece(s) | Quote | DC Reactor | 400 | 280 | - | - | - | - | - | - | - | - | - | - | - | 190 | 440 | 255 | ||
51,690,000 VND | 1 Piece(s) | Quote | DC Reactor | 400 | 315 | - | - | - | - | - | - | - | - | - | - | - | 210 | 495 | 250 | ||
59,445,000 VND | 1 Piece(s) | Quote | DC Reactor | 400 | 355 | - | - | - | - | - | - | - | - | - | - | - | 210 | 495 | 250 |
Loading...Tải…
Compatible Series | FREQROL Series |
---|
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy