(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Mitsubishi thermal relay TH-T series.
[Features]
・ ncredible performance housed in a small body.
・ The even more advanced version of the Mitsubishi Electric electromagnetic opening/closing device.
・ Can be used to detect motor overload and locked rotor current.
・ Product lineup containing overload short circuit protection, time lag and accelerated types for every application.
[Applications]
・ Motor burnout protection.
Applicable to motor protection: can be used for standard motor overload and locking protection.
Easy current value setting: can directly set the motor current value. Adjust with a cross-head / straight-slot screwdriver.
Reset method change: easy to change between manual reset and automatic reset.
With 1a1b contact: can use different voltages for a and b contacts.
Terminal cover as standard equipment (TH-T18/TH-T50): Having a terminal cover as standard equipment reduces the time for customers to specify a separate model name or arrange for options. This reduces inventory and reduces cover costs. Safety has also improved for protecting the live parts.
Outline drawing
Contact Configuration
For combining with the following electromagnetic contactors.
TH-T18:S-T10, T12, T20 SD-T12, T20
Can use as single unit in combination with single unit mounting unit UT-HZ18.
Outline drawing
Contact Configuration
Cannot be used with single unit mounting.
Use the following connection conductor (sold separately) when combining with an electromagnetic contactor.
Combination with S-T35/T50 (BC), SD-T35/T50 (BC): UT-TH50
Outline drawing
Contact Configuration
Use the following connection conductor kit (sold separately) when combining with an electromagnetic contactor.
Combination with S (D) -T65/T80: BH559N350
Combination with S-T100: BH569N350
Combination with SD-T100: BH569N352
Outline drawing
Contact Configuration
Cannot be used with single unit mounting.
Use the following connection conductor kit (sold separately) when combining with an electromagnetic contactor.
Connection conductor kit (sold separately, model name: BH569N350) used
Combination with S (D) -T80: BH559N350
Combination with S-T100: BH569N350
Combination with SD-T100: BH569N352
Part Number |
---|
TH-T25BCKP 6.6A |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Motor capacity/nominal thermal nominal size 440 VAC (kW/A) | Motor Capacity / Thermal Nominal Size VAC 220 (kW/A) | Coil rated voltage (V) | Auxiliary Contact | Representative Standard | Dimension length (mm) | Dimension width (mm) | Dimension thickness (mm) | Specifications | Frame Size | Finger protection/terminal cover | Nominal heater size (A) | Nominal heater size (A) | Settling current adjustment range (A) | Rated insulation voltage (V) | Rate Impulse voltage resistant (kV) | Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 24 V (A) | Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 120 V (A) | Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 240 V (A) | Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 550 V (A) | Rated current used level DC-13 (opening/closing direct current electromagnetic contactor coil) DC 24 V (A) | Rated current used level DC-13 (opening/closing direct current electromagnetic contactor coil) DC 110 V (A) | Rated current used level DC-13 (opening/closing direct current electromagnetic contactor coil) DC 220 V (A) | Application | Terminal screw size (main circuit/operating circuit) | Trip class | Trip free | Reset method | Operation display (lever display) | Manual trip check |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
611,250 VND | 1 Piece(s) | Quote | - | - | - | 1a1b | - | 51 | 63 | 79 | 3 elements (2E) | T25 | With wiring rationalizing terminal | - | 6.6 | 5.2~8 | 690 | 6 | 2/3 | 2/3 | 1/2 | 0.3/0.3 | 1 | 0.2 | 0.1 | For electromagnetic switch | M4/M3.5 | 10A | Standard equipment | Manual/automatic switching possible | Standard equipment | Standard equipment |
Loading...Tải…
Please check the type/dimensions/specifications of the part TH-T25BCKP 6.6A in the Overload Relays TH-T Series series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần TH-T25BCKP 6.6A trong chuỗi Overload Relays TH-T Series.
Part Number |
---|
TH-T100KP 82A |
TH-T18 0.12A |
TH-T18 0.17A |
TH-T25BCKP 9A |
TH-T25KP 0.7A |
TH-T25KP 0.9A |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to ShipSố ngày giao hàng | Motor capacity/nominal thermal nominal size 440 VAC (kW/A) | Motor Capacity / Thermal Nominal Size VAC 220 (kW/A) | Coil rated voltage (V) | Auxiliary Contact | Representative Standard | Dimension length (mm) | Dimension width (mm) | Dimension thickness (mm) | Specifications | Frame Size | Finger protection/terminal cover | Nominal heater size (A) | Nominal heater size (A) | Settling current adjustment range (A) | Rated insulation voltage (V) | Rate Impulse voltage resistant (kV) | Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 24 V (A) | Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 120 V (A) | Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 240 V (A) | Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 550 V (A) | Rated current used level DC-13 (opening/closing direct current electromagnetic contactor coil) DC 24 V (A) | Rated current used level DC-13 (opening/closing direct current electromagnetic contactor coil) DC 110 V (A) | Rated current used level DC-13 (opening/closing direct current electromagnetic contactor coil) DC 220 V (A) | Application | Terminal screw size (main circuit/operating circuit) | Trip class | Trip free | Reset method | Operation display (lever display) | Manual trip check |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
523,750 VND | 1 Piece(s) | Quote | - | - | - | 1a1b | - | 73.5 | 89 | 83.5 | 3 elements (2E) | T100 | NA | - | 82 | 65~100 | 690 | 6 | 2/3 | 2/3 | 1/2 | 0.5/1 | 1 | 0.2 | 0.1 | For electromagnetic switch | M6/M4 | 10 | Standard equipment | Manual/automatic switching possible | Standard equipment | Standard equipment | ||
192,500 VND | 1 Piece(s) | Quote | - | - | - | 1a1b | - | 55 | 45 | 76.5 | Standard/2 elements | T18 | Standard equipment | - | 0.12 | 0.1~016 | 690 | 6 | 2/2 | 2/2 | 1/1 | 0.3/0.3 | 0.5 | 0.2 | 0.1 | For electromagnetic switch | M3.5/M3.5 | 10A | Standard equipment | Manual/automatic switching possible | Standard equipment | Standard equipment | ||
192,500 VND | 1 Piece(s) | Quote | - | - | - | 1a1b | - | 55 | 45 | 76.5 | Standard/2 elements | T18 | Standard equipment | - | 0.17 | 0.14~0.22 | 690 | 6 | 2/2 | 2/2 | 1/1 | 0.3/0.3 | 0.5 | 0.2 | 0.1 | For electromagnetic switch | M3.5/M3.5 | 10A | Standard equipment | Manual/automatic switching possible | Standard equipment | Standard equipment | ||
611,250 VND | 1 Piece(s) | Quote | - | - | - | 1a1b | - | 51 | 63 | 79 | 3 elements (2E) | T25 | With wiring rationalizing terminal | - | 9 | 7~11 | 690 | 6 | 2/3 | 2/3 | 1/2 | 0.3/0.3 | 1 | 0.2 | 0.1 | For electromagnetic switch | M4/M3.5 | 10A | Standard equipment | Manual/automatic switching possible | Standard equipment | Standard equipment | ||
313,750 VND | 1 Piece(s) | Quote | - | - | - | 1a1b | - | 51 | 63 | 79 | 3 elements (2E) | T25 | Standard equipment | - | 0.7 | 0.55~0.85 | 690 | 6 | 2/3 | 2/3 | 1/2 | 0.3/0.3 | 1 | 0.2 | 0.1 | For electromagnetic switch | M4/M3.5 | 10A | Standard equipment | Manual/automatic switching possible | Standard equipment | Standard equipment | ||
313,750 VND | 1 Piece(s) | Quote | - | - | - | 1a1b | - | 51 | 63 | 79 | 3 elements (2E) | T25 | Standard equipment | - | 0.9 | 0.7~1.1 | 690 | 6 | 2/3 | 2/3 | 1/2 | 0.3/0.3 | 1 | 0.2 | 0.1 | For electromagnetic switch | M4/M3.5 | 10A | Standard equipment | Manual/automatic switching possible | Standard equipment | Standard equipment |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy