(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Part Number |
---|
DBH403S-250A |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Number of Poles | Rated Current (A) | TYPE (series name) | Rated breaking current (Icu) kA (Sym) (AC 415/460V) | Rated breaking current (Icu) kA (Sym) (AC 380V) | Rated breaking current (Icu) kA (Sym) (AC 220/250V) | Rated breaking current (Icu) kA (Sym) (DC 500V(3P)) | Rated breaking current (Icu) kA (Sym) (DC 250V(2P)) | ZCT built-in type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
7,775,556 VND | 1 Piece(s) | 10 Day(s) | 3 | 250 | 400AF-H | 65 | 70 | 85 | 40 | - | - |
Loading...Tải…
Ampere frame | 400 AF or more | Rated Voltage (Ue) AC(AC(V)) | 690 | Rated Voltage (Ue) DC(V) | 500 |
---|---|---|---|---|---|
Ics=%×Icu | 100 | Over Current Trip Method | Thermal Magnetic Type | Trip method and protection characteristics (Option) - Adjustment (Note 1) - Rated (Long time) | (0.8-0.9-1.0)×In |
Tripping and protection characteristics (Option) - Fixed - Instantaneous | (8~12)×In | Exterior Dimensions W x H x D - 2P | 140×257×103 | Exterior Dimensions W x H x D - 3P | 140×257×103 |
Exterior Dimensions W x H x D - 4P | 184×257×103 | Frame Size | 400AF |
Please check the type/dimensions/specifications of the part DBH403S-250A in the Molded Case Circuit Breaker (400AF) series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần DBH403S-250A trong chuỗi Molded Case Circuit Breaker (400AF).
Part Number |
---|
DBH402S-300A |
DBH402S-350A |
DBH402S-400A |
DBH403S-300A |
DBH403S-350A |
DBH403S-400A |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to ShipSố ngày giao hàng | Number of Poles | Rated Current (A) | TYPE (series name) | Rated breaking current (Icu) kA (Sym) (AC 415/460V) | Rated breaking current (Icu) kA (Sym) (AC 380V) | Rated breaking current (Icu) kA (Sym) (AC 220/250V) | Rated breaking current (Icu) kA (Sym) (DC 500V(3P)) | Rated breaking current (Icu) kA (Sym) (DC 250V(2P)) | ZCT built-in type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6,634,210 VND | 1 Piece(s) | 10 Day(s) | 2 | 300 | 400AF-H | 65 | 70 | 85 | - | 40 | - | ||
6,634,210 VND | 1 Piece(s) | 10 Day(s) | 2 | 350 | 400AF-H | 65 | 70 | 85 | - | 40 | - | ||
6,634,210 VND | 1 Piece(s) | 10 Day(s) | 2 | 400 | 400AF-H | 65 | 70 | 85 | - | 40 | - | ||
7,775,556 VND | 1 Piece(s) | 10 Day(s) | 3 | 300 | 400AF-H | 65 | 70 | 85 | 40 | - | - | ||
7,775,556 VND | 1 Piece(s) | 10 Day(s) | 3 | 350 | 400AF-H | 65 | 70 | 85 | 40 | - | - | ||
7,775,556 VND | 1 Piece(s) | 10 Day(s) | 3 | 400 | 400AF-H | 65 | 70 | 85 | 40 | - | - |
How can we improve?