(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
[Features]· Universal AC input / Full range.· Withstand 300 V AC surge input for 5 seconds.· Built-in active PFC function.· Protections: Short circuit / Overload / Overvoltage / Over temp. (optional for HRP-75 / HRP-100)· Built-in constant current limiting circuit.· Built-in remote sense function (HRP□-150 / 200)· No load power consumption <0.5 W (except for HRP-150/200)· Built-in remote ON/OFF control (except for HRP-150/200)· Built-in 5 V / 0.3 A standby output (HRPG-150/200)· Cooling by free air convection.· 1U low profile.· LED indicator for power on.· 100% full load burn-in test.
Part Number |
---|
HRP-75-12 |
HRP-100-12 |
PSP-600-12 |
RSP-100-12 |
SPV-150-12 |
SPV-300-12 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Capacity (W) | Output voltage (Single only) | Rated output current (single only) (A) | Included Function | Representative Standard | Dimension height (mm) | Dimension width (mm) | Dimension depth (mm) | Input Voltage (V) | Rated output current 1 for DC 24 V (A) | Rated output current 2 for DC 12 V (A) | Output voltage variation range (V) | AC Input Voltage Range | AC Input current (Maximum) | DC adjustment range | Output Current Range | Effi. | Overload protection | Over voltage protection | Withstand Voltage | Operating temperature | Safety Standard | EMC standards | Other authentication/standards |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2,086,247 VND | 1 Piece(s) | 7 Day(s) | 75 | DC12V | 6.3 | - | UL / TUV | 129 | 98 | 38 | - | - | - | - | 85~264VAC; 120~370VDC | Cold start, 65A at 230VAC | -5%~+10% rated output voltage | - | 87.0% | 105%~135% Constant current limiting, auto-recovery | 115%~145% | I/P-O/P: 3kVAC, I/P-FG: 1.5kVAC, O/P-FG: 0.5kVAC, 1 minute | -40~+70°C (refer to output derating curve) | UL60950-1, TUV EN60950-1 approved | EN55022 class B, EN61000-4-2,3,4,5,6,8,11, EN61000-3-2,3, EN61000-6-2 heavy industry level | - | ||
1,434,622 VND | 1 Piece(s) | 4 Day(s) or more | 100 ~ 102 | DC12V | 8.5 | - | CE / UL / CUL / TUV | 97 ~ 159 | 38 ~ 97 | 38 ~ 169 | - | - | 8.5 | - | 85~264VAC; 120~370VDC | Cold start, 65A at 230VAC | -5%~+10% rated output voltage | - | 87.5% | 105%~135% Constant current limiting, auto-recovery | 115%~145% | I/P-O/P: 3kVAC, I/P-FG: 1.5kVAC, O/P-FG: 0.5kVAC, 1 minute | -40~+60°C | UL60950-1, TUV EN60950-1 approved | EN55022 class B, EN61000-4-2,3,4,5,6,8,11, EN61000-3-2,3, EN61000-6-2 heavy industry level | - | ||
6,611,697 VND | 1 Piece(s) | 7 Day(s) | 600 | DC12V | 50 | - | UL / TUV | 170 | 120 | 93 | AC 88 to 264 / DC 124 to 370 | - | - | 10 to 13.2 | 88~264VAC | Cold start, 40A at 230VAC | ±10% rated output voltage | - | 84% | 105%~135% Constant current limiting,auto-recovery | 115%~140% | I/P - O/P: 3kVAC, I/P - FG: 1.5kVAC, O/P - FG: 0.5kVAC(short for SP-480), 1 minute | -20~+60°C | UL60950-1, TUV EN60950-1 approved; GB4943 approved also for SP-320 (expect for 3.3V/ 5PNC/ 36V) | EN55022 class B, EN61000-4-2,3,4,5,6,8,11, EN61000-3-2,3, EN61000-6-2(SP-480/750), GB9254 (SP-320 only) | EAC/CB | ||
1,799,324 VND | 1 Piece(s) | 7 Day(s) | 100 | DC12V | 8.5 | - | UL / TUV / CCC | 179 | 99 | 30 | - | - | - | - | 85~264VAC; 120~370VDC | 30A at 230VAC | -5%~+10% rated output voltage | - | 86.0% | 105%~150% Constant current limiting, auto-recovery | 110%~135% Shut down O/P voltage, re-power on to recover | I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC | -30~+70°C (refer to output derating curve) | UL60950-1, TUV EN60950-1, EN61558-1, EN61558-2-16, CCC GB4943 approved; UL62368-1 approved for RSP-150 only | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, GB9254 | - | ||
3,058,712 VND | 1 Piece(s) | 7 Day(s) | 150 | DC12V | 12.5 | - | UL / TUV | - | - | - | - | - | - | - | 88~264VAC (SPV-150/300); 90~264VAC (SPV-1500) | Cold start, 40A (SPV-150/300); 60A (SPV-1500) at 230VAC | -15%~+10%(SPV-150/300); ±5%(SPV-1500) rated output voltage | - | 82% | 105%~150% (SPV-150); 105%~135% (SPV-300/1500) constant current limiting, auto-recovery | 115%~140%(SPV-150/300); 120%~140%(SPV-1500) shut down O/P voltage, re-power on to recover | I/P - O/P: 3kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC | -20~+65°C(SPV-150/300); -20~+70°C(SPV-1500) | UL60950-1, TUV EN60950-1 approved | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 | - | ||
3,861,404 VND | 1 Piece(s) | 7 Day(s) | 300 | DC12V | 25 | - | UL / TUV | - | - | - | - | - | - | - | 88~264VAC (SPV-150/300); 90~264VAC (SPV-1500) | Cold start, 40A (SPV-150/300); 60A (SPV-1500) at 230VAC | -15%~+10%(SPV-150/300); ±5%(SPV-1500) rated output voltage | - | 83.5% | 105%~150% (SPV-150); 105%~135% (SPV-300/1500) constant current limiting, auto-recovery | 115%~140%(SPV-150/300); 120%~140%(SPV-1500) shut down O/P voltage, re-power on to recover | I/P - O/P: 3kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC | -20~+65°C(SPV-150/300); -20~+70°C(SPV-1500) | UL60950-1, TUV EN60950-1 approved | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 | - |
Loading...Tải…
Shape | With Cover | Single/multi | Single | Input Voltage | AC/DC |
---|---|---|---|---|---|
Input/output terminal shape | Screw |
How can we improve?