(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Safety relay unit G9SA
[Features]
· Small size, with an abundant series.
· 45 mm width, with an abundant variety of 3-pole. 5-pole, 3-pole + off delay 2-pole, 2 hand controllers.
· We also offer 17.5 mm width 3-pole, off delay 3-pole expansion units.
· Expansion units can be connected with a single action.
· Off delay types can be set at 15 different time levels.
· Certified ENISO13849-1 (PLe/Safety Category 4).
· Can be DIN rail mounted or screw mounted.
Main Contact | Auxiliary Contact | Number of Input Channels | Rated Voltage | Format |
---|---|---|---|---|
3 a | 1 b | 1 ch and 2 ch shared | 24 V AC/DC | Model G9SA-301 |
100 to 240 V AC | ||||
5 a | 24 V AC/DC | Model G9SA-501 | ||
100 to 240 V AC |
Emergency stop unit of Industrial Relays
Main Contact | OFF Delay Contact | Auxiliary Contact | Number of Input Channels | OFF Delay Time | Rated Voltage | Format |
---|---|---|---|---|---|---|
3 a | 2 a | 1 b | 1 ch and 2 ch shared | 7.5 secs | 24 V AC/DC | Model G9SA-321-T075 |
15 secs | 24 V AC/DC | Model G9SA-321-T15 | ||||
30 secs | 24 V AC/DC | Model G9SA-321-T30 |
Emergency stop unit with OFF delay of Industrial Relays
The OFF delay time is variable in 15 steps. The following times can be set:
T075: 0.5/1/1.5/2/2.5/3/3.5/4/4.5/5/5.5/6/6.5/7/7.5 secs
T15: 1/2/3/4/5/6/7/8/9/10/11/12/13/14/15 secs
T30: 2/4/6/8/10/12/14/16/18/20/22/24/26/28/30 secs
Main Contact | Auxiliary Contact | Number of Input Channels | Reset Mode | Input Type | Rated Voltage | Format |
---|---|---|---|---|---|---|
2 a | None | 2 ch | Auto | Inverse | 24 V AC/DC | Model G9SB-2002-A |
1 ch, 2 ch | Positive Common | Model G9SB-200-B | ||||
2 ch | Manual | Inverse | Model G9SB-2002-C | |||
1 ch, 2 ch | Positive Common | Model G9SB-200-D | ||||
3 a | 1 b | No (Power supply directly OFF) | Auto | -- | 24 V DC | Model G9SB-3010 |
2 ch | Inverse | 24 V AC/DC | Model G9SB-3012-A | |||
1 ch, 2 ch | Positive Common | Model G9SB-301-B | ||||
2 ch | Manual | Inverse | Model G9SB-3012-C | |||
1 ch, 2 ch | Positive Common | Model G9SB-301-D |
Format | Model G9SA-301 | Model G9SA-501 | Model G9SA-321-T□ |
---|---|---|---|
Power Supply Voltage | 24 V AC/DC: 24 V AC, 50/60 Hz / 24 V DC, 100 to 240 V AC: 100 to 240 V AC, 50/60 Hz | ||
Allowable Voltage Fluctuation Range | Power supply voltage -15% +10% | ||
Power Consumption | 24 V AC/DC: 1.8 VA/1.7 W max. 100 to 240 V AC: 9 VA max. | 24 V AC/DC: 2.8 VA/2.6 W max. 100 to 240 V AC: 11 VA max. | 24 V AC/DC: 3.5 VA/3.3 W max. 100 to 240 V AC: 12.5 VA max. |
Power supply: G9SA type
Format | Model G9SB-200□-□ | Model G9SB-3010 | Model G9SB-301□-□ |
---|---|---|---|
Power Supply Voltage | 24 V AC/DC: 24 V AC, 50/60 Hz / 24 DC, 24 V DC: 24 V DC | ||
Allowable Voltage Fluctuation Range | Power supply voltage -15% +10% | ||
Power Consumption | 1.6 VA / 1.4 W max. | 1.7 W max. | 2.0 VA / 1.7 W max. |
Power supply: G9SB type
Format | Model G9SA-301/321-T□ | Model G9SA-501 |
---|---|---|
Input Current | 40 mA max. | 60 mA max. |
Input: G9SA type
Format | Model G9SB-200□-□ | Model G9SA-3010 | Model G9SB-301□-□ |
---|---|---|---|
Input Current | 25 mA max. | 60 mA max. | 30 mA max. |
Input: G9SB type
Format | Model G9SA-301/501/321-T□ |
---|---|
Load | Resistive Load |
Rated Load | 250 V AC 5 A, 30 V DC 5 A |
Rated Carry Current | 5 A |
Switch: G9SA type
Format | Model G9SB-200□-□, Model G9SB-3010, Model G9SB-301□-□ |
---|---|
Load | Resistive Load |
Rated Load | 250 V AC 5 A, 30 V DC 5 A |
Rated Carry Current | 5 A |
Switch: G9SB type
Format | Model G9SA-301 | Model G9SA-501/321-T□ | |
---|---|---|---|
Contact Resistance | 100 mΩ | ||
Operating Time | 30 ms max. | ||
Response Time | 10 ms max. | ||
Insulation Resistance | 100 MΩ min., 500 V DC ohmmeter | ||
Dielectric Strength | Between Different Outputs | 2,500 V AC 50/60 Hz 1 min | |
Between Input and Output | |||
Between Power Supply and Output | |||
Between Power Supply and Input (100 to 240 V AC only) | |||
Vibration Resistance | 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) | ||
Shock Resistance | Durability | 300 m/s2 | |
Malfunction | 100 m/s2 | ||
Durability | Mechanical | 5,000,000 operations min. (at approx. 7,200 operations/hr) | |
Electrical | 100,000 operations min. (at 1,800 operations/hr under rated load) | ||
Failure Rate (P Level) (Reference Value) | 5 V DC 1 mA | ||
Ambient Operating Temperature | -25 to +55°C (assuming no icing or condensation) | ||
Ambient Operating Humidity | 35 to 85% RH | ||
Terminal Tightening Torque | 0.98 N·m | ||
Weight | Approx. 210 g | Approx. 270 g |
Format | Model G9SB-200□-□ | Model G9SB-3010 | Model G9SB-301□-□ | |
---|---|---|---|---|
Contact Resistance | 100 mΩ | |||
Operating Time | 30 ms max. | |||
Response Time | 10 ms max. | |||
Insulation Resistance | 100 MΩ min., 500 V DC ohmmeter | |||
Dielectric Strength | Between Different Outputs | 2,500 V AC 50/60 Hz 1 min | ||
Between Input and Output | ||||
Between Power Supply and Output | ||||
Vibration Resistance | 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) | |||
Shock Resistance | Durability | 300 m/s2 | ||
Malfunction | 100 m/s2 | |||
Durability | Mechanical | 5,000,000 operations min. (at approx. 7,200 operations/hr) | ||
Electrical | 100,000 operations min. (at 1,800 operations/hr under rated load) | |||
Failure Rate (P Level) (Reference Value) | 5 V DC 1 mA | |||
Ambient Operating Temperature | -25 to +55°C (assuming no icing or condensation) | |||
Ambient Operating Humidity | 35 to 85% RH | |||
Terminal Tightening Torque | 0.5 N·m | |||
Weight | Approx. 115 g | Approx. 135 g | Approx. 120 g |
Units: mm
Model G9SA-301
Model G9SA-501
Model G9SA-321-T□ full view
Dimensional outline drawings of Industrial Relays
Units: mm
Model G9SB-200□-□
Model G9SB-3010 full view
Dimensional outline drawings of Industrial Relays
Units: mm
Model G9SB-301□-□ full view
Dimensional outline drawings of Industrial Relays
Part Number |
---|
G9SB-2002-A AC/DC24 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Contact Configuration | Representative Standard | Dimension height (mm) | Dimension width (mm) | Dimension depth (mm) | Classification | Off delay time (Second) | Rated Voltage (V) | Reset Mode | Input Type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
4,280,000 VND | 1 Piece(s) | 6 Day(s) or more | 2a | CE / UL / TUV / CCC / CSA | 100 | 18 | 112 | Emergency Stop Unit | - | AC/DC24 | Auto | Inverse |
Loading...Tải…
Application | Safety relay | Latch function | NA | Terminal shape | Screw Fastening |
---|
Please check the type/dimensions/specifications of the part G9SB-2002-A AC/DC24 in the Safety/Relay Unit G9SA series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần G9SB-2002-A AC/DC24 trong chuỗi Safety/Relay Unit G9SA.
Part Number |
---|
G9SA-321-T15 AC/DC24 |
G9SA-321-T30 AC/DC24 |
G9SA-501 AC/DC24 |
G9SB-2002-C AC/DC24 |
G9SB-301-B AC/DC24 |
G9SB-301-D AC/DC24 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to ShipSố ngày giao hàng | Contact Configuration | Representative Standard | Dimension height (mm) | Dimension width (mm) | Dimension depth (mm) | Classification | Off delay time (Second) | Rated Voltage (V) | Reset Mode | Input Type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
9,106,496 VND | 1 Piece(s) | Same day | [Other] 3a2a1b | CE / UL / CCC / CSA | 76 | 45 | 111 | Emergency Stop Unit - With OFF Delay | 15 | AC/DC24 | - | - | ||
6,890,000 VND | 1 Piece(s) | Same day | [Other] 3a2a1b | CE / UL / CCC / CSA | 76 | 45 | 111 | Emergency Stop Unit - With OFF Delay | 30 | AC/DC24 | - | - | ||
5,900,000 VND | 1 Piece(s) | 11 Day(s) | [Other] 5a1b | CE / UL / CCC / CSA | 76 | 45 | 111 | Emergency Stop Unit | - | AC/DC24 | - | - | ||
4,280,000 VND | 1 Piece(s) | 11 Day(s) | 2a | CE / UL / TUV / CCC / CSA | 100 | 18 | 112 | Emergency Stop Unit | - | AC/DC24 | Manual | Inverse | ||
5,390,000 VND | 1 Piece(s) | 11 Day(s) | [Other] 3a1b | CE / UL / TUV / CCC / CSA | 100 | 23 | 112 | Emergency Stop Unit | - | AC/DC24 | Auto | Positive Common | ||
5,390,000 VND | 1 Piece(s) | Same day | [Other] 3a1b | CE / UL / TUV / CCC / CSA | 100 | 23 | 112 | Emergency Stop Unit | - | AC/DC24 | Manual | Positive Common |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy