(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
[Features]
· Safety rail for safety light curtain F3SJ-E. G7S.
Classification | Number Of Poles | Contact Configuration | Rated Voltage | Format |
---|---|---|---|---|
Standard Type | 6 poles | 4 a 2 b | 24 V DC | Model G7S-4A2B-E |
3 a 3 b | Model G7S-3A3B-E |
G7S-4A2B-E/G7S-3A3B-E external appearance
G7S-4A2B-E/G7S-3A3B-E dimensional drawings, Units: mm
G7S-4A2B-E terminal layout / internal schematics
G7S-3A3B-E terminal layout / internal schematics
Mounting hole dimensions, Units: mm
Rated Voltage | Rated Current (mA) | Coil Resistance (Ω) | Maximum Continuous Allowable Voltage (V) | Power Consumption (W) |
---|---|---|---|---|
24 V DC | 30 | 800 | 110% | Approx. 0.8 |
Load | Resistive Load | |
---|---|---|
Rated Load | a-Contact | 250 V AC 10 A, 30 V DC 10 A |
b Contact | 250 V AC 6 A, 30 V DC 6 A | |
Rated Carry Current | a-Contact | 10 A |
b Contact | 6 A | |
Max. Contact Voltage Value | 250 V AC, 30 V DC | |
Max. Contact Current Value | a-Contact | 10 A |
b Contact | 6 A |
Contact Resistance *1 | 100 mΩ max. | |
---|---|---|
Operating Time *2 | 50 ms max. | |
Recovery Time *2 | 50 ms max. | |
Operating Voltage | 80% max. relative to rated voltage | |
Release Voltage | 10% min. relative to rated voltage | |
Maximum Switching Frequency | Mechanical | 18,000 operations/hr |
Rated Load | 1,800 operations/hr | |
Insulation Resistance *3 | 100 MΩ min. | |
Dielectric Strength *4 *5 | Between coil and contacts (between coil and pole 3 or coil and pole 4): 4,000 VAC, 50/60 Hz for 1 min Between coil and contacts (other than the above): 2,500 VAC, 50/60 Hz for 1 min Between different poles (between pole 1, 3, or 5 and pole 2, 4, or 6): 4,000 VAC, 50/60 Hz for 1 min Between different poles (other than the above): 2,500 VAC, 50/60 Hz for 1 min Between contacts of same polarity: 1,500 VAC, 50/60 Hz for 1 min | |
Vibration | Durability | 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) |
Malfunction | 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) | |
Shock | Durability | 1,000 m/s2 |
Malfunction | 100 m/s2 | |
Durability *6 | Mechanical | 10,000,000 operations min. (switching frequency 18,000 operations/hr) |
Electrical | 100,000 operations min. (at 1,800 operations/hr under rated load) | |
Inductive Load Switching Performance *7 (IEC60947-5-1) | a-Contact | AC15 240 V AC 5 A DC13 24 V DC 2 A |
b Contact | AC15 240 V AC 3 A DC13 24 V DC 2 A | |
Failure Rate (P Level) (Reference Value *8) | 5 V DC 1 mA | |
Ambient Operating Temperature | -25 to +70°C (assuming no icing or condensation) | |
Ambient Operating Humidity | 5 to 85% RH | |
Weight | Approx. 65 g |
*1. Measurement conditions: 5 V DC, 10 mA, voltage drop method.
*2. Measurement conditions: rated voltage operation. Ambient temperature conditions: +23°C. Bounce time not included.
*3. Measured with a 500 V DC ohmmeter at the same places that the dielectric strength was checked.
*4. When using a P7S socket, the dielectric strength between coil contacts/different poles is 2,000 V AC, 50/60 Hz for 1 min.
*5. The coil refers to terminals 0-1, pole 1 refers to terminals 13−14, pole 2 refers to terminals 23−24, pole 3 refers to terminals 33−34, pole 4 refers to terminals 41−42 or 43−44, pole 5 refers to terminals 51−52, and pole 6 refers to terminals 61−62.
*6. The durability is for an ambient temperature of 15 to +35°C and an ambient humidity of 25% to 75% RH.
*7. AC15: cosφ = 0.3 mm, DC13: L/R = 96 ms inductive load.
*8. This value is based on a switching frequency of 60 operations/min.
Part Number |
---|
G7S-3A3B-E DC24 |
G7S-4A2B-E DC24 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Contact Configuration |
---|---|---|---|---|---|
737,000 VND | 1 Piece(s) | Same day | [Other] 3a3b | ||
737,000 VND | 1 Piece(s) | Same day | [Other] 4a2b |
Loading...Tải…
Application | Safety relay | Latch function | NA | Terminal shape | Socket / plug-in |
---|---|---|---|---|---|
Contact rated current (minimum value for AC and DC)(A) | 6 | Coil rated voltage (DC)(V) | 24 | Representative Standard | UL / CSA |
Dimension height(mm) | 37 | Dimension width(mm) | 22.5 | Dimension depth(mm) | 58 |
Classification | Standard Type | Note | Dangerous situations in and around the machinery are avoided by the use of an interlock type circuit configuration. |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy