(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
[Features]
· A general purpose, affordable, two pole relay for signals with a general purpose DIL terminal array.
· Features a wide contact switching region of 10 μA to 2 A.
· A sealed plastic type. Equipped as standard with crossbar twin contacts.
· High environmental resistance and high reliability.
· FCCpart68 compliant (1,500V, 10 × 160 μs) for between coil-contacts and between identical polarity-contacts.
· High withstand voltage of AC100V between coil-contacts and AC750V between identical polarity contacts.
· UL, CSA certified.
· 150mWtypes also available.
Model G5V-2 external appearance
Model G5V-2 dimensional outline drawing
PCB processing dimensions
The dimensional tolerance is ±0.1 mm.
Terminal layout/schematics
There is no coil polarity.
Class- ification | Items Rated Voltage (V) | Rated Current (mA) | Coil Resistance (Ω) | Operating Voltage (V) | Release Voltage (V) | Maximum Allowable Voltage (V) | Power Consumption (mW) | |
---|---|---|---|---|---|---|---|---|
Stan- dard Type | DC | 3 | 166.7 | 18 | 75% or Less | 5% or More | 120% (at 23°C) | Approx. 500 |
5 | 100 | 50 | ||||||
6 | 83.3 | 72 | ||||||
9 | 55.6 | 162 | ||||||
12 | 41.7 | 288 | ||||||
24 | 20.8 | 1,152 | ||||||
48 | 12 | 4,000 | Approx. 580 | |||||
Ultra- High- Sensi- tivity Type | DC | 5 | 30 | 166.7 | 75% or Less | 5% or More | 180% (at 23°C) | Approx. 150 |
12 | 12.5 | 960 | ||||||
24 | 8.33 | 2,880 | Approx. 200 | |||||
48 | 6.25 | 7,680 | 150% (at 23°C) | Approx. 300 |
Note 1: The rated current and coil resistance are measured at a coil temperature of +23°C and a tolerance of 10%.
Note 2: The operating characteristics are measured at a coil temperature of +23°C.
Note 3: The maximum allowable voltage is the maximum voltage that can be applied to a relay coil.
Items | Classification Load | Standard Type | Ultra-High-Sensitivity Type |
---|---|---|---|
Resistance Load | |||
Contact Touching Mechanism | Crossbar Twin Contacts | ||
Contact Material | Au Alloy + Ag | ||
Rated Load | 125 V AC 0.5 A, 30 V DC 2 A | 125 V AC 0.5 A, 24 V DC 1 A | |
Rated Conduction Current | 2 A | ||
Maximum Contact Voltage Value | 125 V AC, 125 V DC | ||
Maximum Contact Current Value | 2 A | 1 A |
Items | Classification | Standard Type | Ultra-High-Sensitivity Type |
---|---|---|---|
Contact Resistance *1 | 50 mΩ or Less | 100 mΩ or Less | |
Turn-ON Time | 7 ms or Less | ||
Turn-OFF Time | 3 ms or Less | ||
Insulation Resistance *2 | 1,000 MΩ or More (500 V DC Megohmmeter) | ||
Withstand Voltage | Between Coil and Contact | 1,000 V AC 50/60 Hz 1 min | |
Between Contacts of Same Polarity | 750 V AC 50/60 Hz 1 min | 500 V AC, 50/60 Hz, 1 min | |
Between Contacts of Different Polarities | 1,000 V AC 50/60 Hz 1 min | ||
Vibration | Durability | 10 to 55 to 10 Hz, Semi Amplitude 0.75 mm (Double Amplitude 1.5 mm) | |
Malfunction | 10 to 55 to 10 Hz, Semi Amplitude 0.75 mm (Double Amplitude 1.5 mm) | ||
Shock / Impact | Durability | 1,000 m/s2 | |
Malfunction | 200 m/s2 | 100 m/s2 | |
Durability | Mechanical | 15,000,000 Times or More (Switching Frequency: 36,000 Times/h) | |
Electrical | 100,000 Times or More (Switching Frequency: 1,800 Times/h) | AC 100,000 Times or More, DC 300,000 Times or More (Switching Frequency: 1,800 Times/h) | |
Failure Rate P Level (Reference Value *3) | DC 10 mV 10 μA | ||
Ambient Operating Temperature | -25 to +65°C (Assuming No Freezing or Condensation) | -25 to +70°C (Assuming No Freezing or Condensation) | |
Operating Ambient Humidity | 5 to 85% RH | ||
Weight | Approx. 5 g |
Note: The above values are the initial default values.
*1. Measurement conditions: 1 V DC 10 mA, voltage drop method.
*2. Measurement conditions: Measuring the same spot for the withstand voltage items using a 500 V DC insulation resistance meter.
*3. This value is obtained with a switching frequency of 120 times/min. and a contact resistance failure value of 50 Ω.
These values may vary depending on switching frequency and operating conditions, meaning it is always recommended to double-check under actual load conditions.
Part Number |
---|
G5V-2 DC5 |
G5V-2 DC24 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Coil rated voltage (DC) (V) |
---|---|---|---|---|---|
81,250 VND | 1 Piece(s) | Same day | 5 | ||
90,091 VND | 1 Piece(s) | 9 Day(s) | 24 |
Loading...Tải…
Application | For Signals | Contact Configuration | 2c | Latch function | NA |
---|---|---|---|---|---|
Terminal shape | For Circuit Boards | Contact rated current (minimum value for AC and DC)(A) | 0.5 | Dimension height(mm) | 11.5 |
Dimension width(mm) | 10.1 | Dimension depth(mm) | 20.5 | Classification | Standard Type |
Protective Structure | Plastic seal type | Contact mechanism | Crossbar twin | Circuit Board Mounting | Circuit Board Hole Insertion |
AC rated load(V)/(A) | AC125/0.5 | DC rated load(V)/(A) | DC30/2 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy