(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Other multi-pin power relay in contactor current range that can be opened and closed by energizing 440 V AC / 40 A as a relay.
[Features]
・ 1 pole 40 A can be energized
・ Maximum energization capacity when 4 poles are connected in parallel is 160 A
・ Obtained EN60947-4-1 mirror contact mechanism certification by combining the relay body and auxiliary contact block
・ Designed with few openings to prevent dust and foreign matter from entering
・ Ideal for energizing industrial inverters, servo drivers, etc., and opening and closing power supplies for motors, etc.
・ Compliant with European PV standard (VDE0126)
[Applications]
・ Mainly available for control panels, industrial machines, etc.
A maximum load capacity of 160 A when using 4-pole connections
Relay main unit (12 V, 24 V DC) + auxiliary contact block set, 4-pole dimensional drawing
Structure | Contact Configuration | Rated Voltage | Format | ||
---|---|---|---|---|---|
Relay Main Body | Auxiliary Contact Block | ||||
Relay Main Body + Auxiliary Contact Block Set | 4 Poles + 2 Poles | 4 A | 2 a | 12, 24 V DC | Model G7Z-4A-20Z |
1 a 1 b | 24 V | Model G7Z-4A-11Z | |||
2 b | 24 V | Model G7Z-4A-02Z | |||
3 A 1 B | 1 a 1 b | 24 V | Model G7Z-3A1B-11Z | ||
2 A 2 B | 1 a 1 b | 24 V | Model G7Z-2A2B-11Z |
Relay main body + auxiliary contact block set (for screw terminals)
Rated Voltage (V) | Rated Current (mA) | Coil Resistance (Ω) | Operating Voltage | Release Voltage | Maximum Allowable Voltage | Power Consumption (W) | |
---|---|---|---|---|---|---|---|
On the Basis of Rated Voltage | |||||||
DC | 12 | 308 | 39 | 75% max. | 10% min. | 110% | Approx. 3.7 |
24 | 154 | 156 |
Ratings / Operation Coil
Format | Model G7Z-4A-□Z, Model G7Z-3A1B-□Z, Model G7Z-2A2B-□Z | |||
---|---|---|---|---|
Load | Resistive Load | Inductive Load (cosø = 0.3) | Resistive Load L/R = 1 ms | |
Contact Mechanism | Double break | |||
Contact Material | Ag alloy | |||
Rated Load | a-Contact | 440 V AC 40 A | 440 V AC 22 A | 110 V DC 5 A |
b Contact | 440 V AC 25 A | 440 V AC 10 A | 110 V DC 5 A | |
Rated Carry Current | a-Contact | 40 A * | ||
b Contact | 25 A | |||
Max. Contact Voltage Value | 480 V AC | 125 V DC | ||
Max. Contact Current Value | a-Contact | 40 A | 22 A | 5 A |
b Contact | 25 A | 10 A | 5 A | |
Maximum Switching Capacity Value | a-Contact | 17,600 VA | 9,680 VA | 550 W |
b Contact | 11,000 VA | 4,400 VA | 550 W | |
Failure Rate (P Level) (Reference Value) | 24 V DC 2 A |
Switch (Contact) / Relay Main Body
*Set of relay and auxiliary contact block: 45 to 60°C; for the continuous carry current, reduce 40 A by 0.7 A/°C.
Classification | Relay Main Body *5 | |
---|---|---|
Format | Model G7Z-4A-□Z Model G7Z-3A1B-□Z Model G7Z-2A2B-□Z | |
Contact Resistance *1 | 400 mΩ max. | |
Operating Time *2 | 50 ms max. | |
Recovery Time *2 | 50 ms max. | |
Maximum Switching Frequency | Mechanical | 1,800 operations/hr |
Rated Load | 1,200 operations/hr | |
Insulation Resistance *3 | 1,000 MΩ min. | |
Dielectric Strength | Between Coil And Contact | 4,000 V AC 50/60 Hz for 1 min |
Between Contacts of Different Polarity | 4,000 V AC 50/60 Hz for 1 min | |
Between Contacts of Same Polarity | 2,000 V AC 50/60 Hz for 1 min | |
Impulse Withstand Voltage | Between Coil And Contact | 10 kV 1.2 × 50 μs |
Between Contacts of Different Polarity | 10 kV 1.2 × 50 μs | |
Between Contacts of Same Polarity | 4.5 kV 1.2 × 50 μs | |
Vibration | Durability | 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude) |
Malfunction | a-contact: 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude) b-contact: 10 to 32 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude) | |
Shock | Durability | Screw mounting: 700 m/s2, DIN track mounting: 500 m/s2 |
Malfunction | a-contact: 100 m/s2 b-contact: 25 m/s2 | |
Durability | Mechanical | 1,000,000 operations min. (at 1,800 operations/h, contact no load) |
Electrical *4 | AC resistive load: 80,000 operations AC inductive load: 80,000 operations DC resistive load: 100,000 operations (at 1,200 operations/hr, rated load) | |
Failure Rate (P Level) (Reference Value) *6 | 24 V DC 2 A | |
Ambient Operating Temperature | -25 to +60°C (assuming no icing or condensation) | |
Ambient Operating Humidity | 5 to 85% RH | |
Weight | Approx. 330 g |
Performance
*1. Measurement conditions: The contact resistance for the relay (G7Z) was measured with 1 A at 5 V DC using the voltage drop method. G73Z auxiliary Contact block: measured with 0.1 A at 5 VDC using the voltage drop method.
* 2. Measured with the rated voltage applied with any contact bounce ignored and at an ambient temperature of 23°C.
* 3. Measured with a 1,000 V DC ohmmeter at the same places that the dielectric strength was checked.
* 4. Ambient temperature: +23°C
*5. This value was measured at a switching frequency of 1,800 operations/hr.
* 6. The performance of the auxiliary contact block mounted on the G7Z is the same as that for the G73Z auxiliary contact block.
Part Number |
---|
G7Z-2A2B-11Z DC24 |
G7Z-2A2B DC24 |
G7Z-3A1B-11Z DC24 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Contact Configuration | Contact rated current (minimum value for AC and DC) (A) | Dimension depth (mm) | Auxiliary contact configuration | Contact mechanism | AC rated load (AUX contact) | DC rated load (AUX contact) |
---|---|---|---|---|---|---|---|---|---|---|---|
1,249,196 VND | 1 Piece(s) | Same day | [Other] 2a2b | 40/25 | 84 | 1a1b | Crossbar twin | AC440V/1A | DC110V/0.5A | ||
1,096,406 VND | 1 Piece(s) | Same day | [Other] 2a2b | 40/25 | 60 | - | - | - | - | ||
965,000 VND | 1 Piece(s) | Same day | [Other] 3a1b | 40/25 | 84 | 1a1b | Crossbar twin | AC440V/1A | DC110V/0.5A |
Loading...Tải…
Application | Power | Terminal shape | Screw terminal | Coil rated voltage (DC)(V) | 24 |
---|---|---|---|---|---|
Representative Standard | CE / UL / TUV / CCC / CSA | Dimension height(mm) | 62 | Dimension width(mm) | 45 |
AC rated load | AC440 40 A (a contact)/ 25 A (b contact) | DC rated load | DC110 5 A (a contact)/ 5 A (b contact) |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy