(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Taiwan Meanwell Corp. is the world's third largest sales scale standard power supply manufacturer
The optimum capacity for auxiliary power supplies for relays and sensors in the control panel, the DIN rail type (35 mm: DIN rail attachable)
Part Number |
---|
MDR-20-5 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Capacity (W) | Output voltage (Single only) | Rated output current (single only) (A) | Representative Standard | Dimension height (mm) | Dimension width (mm) | Rated output current 2 for DC 12 V (A) | Rated output current 3 for DC 5 V (A) | AC Input Voltage Range | AC Input current (Maximum) | DC adjustment range | Effi. | Overload protection | Over voltage protection | Withstand Voltage | Operating temperature | Safety Standard | EMC standards |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
624,900 VND | 1 Piece(s) | 4 Day(s) or more | 20 | DC5V | 3 | CE / UL / CUL / TUV | 22.5 ~ 90 | 22.5 ~ 90 | - | 3 | 85~264VAC; 120~370VDC | Cold start, 20A at 115VAC, 40A at 230VAC | ±10% rated output voltage | 76% | 105%~160% constant current limiting, auto-recovery | 115%~135% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -20~+70°C (refer to output derating curve) | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) |
Loading...Tải…
Shape | DIN rail direct attachment | Single/multi | Single | Input Voltage | AC/DC |
---|---|---|---|---|---|
Input/output terminal shape | European format | Dimension depth(mm) | 100 |
Please check the type/dimensions/specifications of the part MDR-20-5 in the Power Supply 10~96W Ultra Slim DIN Rail Power, MDR Series series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần MDR-20-5 trong chuỗi Power Supply 10~96W Ultra Slim DIN Rail Power, MDR Series.
Part Number |
---|
MDR-10-5 |
MDR-100-12 |
MDR-20-12 |
MDR-40-12 |
MDR-40-5 |
MDR-60-12 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to ShipSố ngày giao hàng | Capacity (W) | Output voltage (Single only) | Rated output current (single only) (A) | Representative Standard | Dimension height (mm) | Dimension width (mm) | Rated output current 2 for DC 12 V (A) | Rated output current 3 for DC 5 V (A) | AC Input Voltage Range | AC Input current (Maximum) | DC adjustment range | Effi. | Overload protection | Over voltage protection | Withstand Voltage | Operating temperature | Safety Standard | EMC standards |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
701,370 VND | 1 Piece(s) | 4 Day(s) or more | 10 | DC5V | 2 | UL / CE / TUV / CUL | 22.5 ~ 90 | 22.5 ~ 90 | - | 2 | 85~264VAC; 120~370VDC | Cold start, 35A at 115VAC, 70A at 230VAC | Fixed | 77% | >105% hiccup mode, auto-recovery | 115%~135% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -20~+70°C (refer to output derating curve) | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) | ||
1,324,788 VND | 1 Piece(s) | 4 Day(s) or more | 100 | DC12V | 7.5 | UL / CE / TUV / CUL | 55 ~ 90 | 55 ~ 90 | 7.5 | - | 85~264VAC; 120~370VDC | Cold start, 30A at 115VAC, 60A at 230VAC | 0~+20% rated output voltage | 83% | 105%~150% constant current limiting, auto-recovery | 125%~150% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -10~+60°C | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) | ||
624,900 VND | 1 Piece(s) | 4 Day(s) or more | 20 | DC12V | 1.67 | UL / CE / TUV / CUL | 22.5 ~ 90 | 22.5 ~ 90 | 1.67 | - | 85~264VAC; 120~370VDC | Cold start, 20A at 115VAC, 40A at 230VAC | ±10% rated output voltage | 80% | 105%~160% constant current limiting, auto-recovery | 115%~135% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -20~+70°C (refer to output derating curve) | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) | ||
749,880 VND | 1 Piece(s) | 4 Day(s) or more | 40 | DC12V | 3.33 | UL / CE / TUV / CUL | 40 ~ 90 | 40 ~ 90 | 3.33 | - | 85~264VAC; 120~370VDC | Cold start, 30A at 115VAC, 60A at 230VAC | 0~+20% rated output voltage | 86% | 105%~150% constant current limiting, auto-recovery | 125%~150% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -20~+70°C (refer to output derating curve) | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) | ||
749,880 VND | 1 Piece(s) | 4 Day(s) or more | 40 | DC5V | 6 | CE / TUV / CUL | 90 | 40 | - | 6 | - | - | - | - | - | - | - | - | - | - | ||
849,864 VND | 1 Piece(s) | 4 Day(s) or more | 60 | DC12V | 5 | UL / CE / TUV / CUL | 40 ~ 90 | 40 ~ 90 | 5 | - | 85~264VAC; 120~370VDC | Cold start, 30A at 115VAC, 60A at 230VAC | 0~+20% rated output voltage | 86% | 105%~150% constant current limiting, auto-recovery | 125%~150% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -20~+70°C (refer to output derating curve) | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy