(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Caution
thận trọng
Wide input voltage, circuit board starter type, a wide variety of variations with models from 10 W to 300 W, 300 W model.
[Features]
·When the remote control is off, the option "-R2" with reduced standby power (1.1 W typ at 200 V AC) is set
·Screw fall prevention mechanism is used for input and output terminal blocks
·High efficiency by adopting synchronous rectification (3.3, 5 V product)
·Harmonic current regulation compliant (Compliant with IEC61000-3-2)
·24 V has achieved natural air cooling 300 W (peak 456 W)
·The option "-SNF" with built-in forced draft fan is set (5 V, 12 V, 24 V)
·Wide input voltage (AC85 to 264 V)
·Power rate improvement
·Mounting compatibility with LGA series (100 V AC input)
·With inrush current prevention circuit, overcurrent and overvoltage protection circuit
·Compliant with various safety standards (L60951-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178-acquired, the Electrical Appliances and Materials Safety Act compliant
·Compatible with SEMI F47 standard
[Applications]
·It can be used for various general-purpose devices
LFA300F
Downsizing (28% reduction in floor area compared to the conventional model) same floor area as LGA240 A
When the remote control is off, the option "-R2" with reduced standby power (1.1 W typ at 200 V AC) is set
Screw fall prevention mechanism is used for input and output terminal blocks
High efficiency by adopting synchronous rectification (3.3, 5 V product)
Harmonic current regulation compliant (Compliant with IEC61000-3-2)
24 V has achieved natural air cooling 300 W (peak 456 W)
The option "-SNF" with built-in forced draft fan is set (5 V, 12 V, 24 V)
Extensive optional parts such as dedicated harness
Compatible with SEMI F47 standard
1 Series name
2 Single output
3 Rated output power
4 Full range input
5 Rated output voltage
→6 continues to the right
6 options
C: Coating
G: Low leakage current
H: Peak current compatible (24 V or more)
J: EP (Tyco Electronics) connector (12 V or more)
J1: VH (J.S.T) connector (12 V or more)
R: With remote ON/OFF
R2: With remote control
S: With chassis
SN: With chassis and cover
SNF: With fan (5 V, 12 V, 24 V)
T: Terminal block horizontal type
Y: With potentiometer
— | Item | LFA300F-3R3-TY | LFA300F-5-TY | LFA300F-12-TY | LFA300F-15-TY | LFA300F-24-TY | LFA300F-24-HTY | LFA300F-30-TY | LFA300F-36-TY | LFA300F-48-TY | |
---|---|---|---|---|---|---|---|---|---|---|---|
Maximum output power [W]*5 | 198 | 300 | 324 | 330 | 336 | 336 (456) | 330 | 338.4 | 336 | ||
DC output *5 | Natural air cooling | 3.3 V 40 A | 5 V 40 A | 12 V 17 A | 15 V 14 A | 24 V 12.5 A | 24 V 12.5 (19) A | 30 V 10 A | 36 V 8.4 A | 48 V 6.3 A | |
Forced draft fan | 3.3 V 60 A | 5 V 60 A | 12 V 27 A | 15 V 22 A | 24 V 14 A | 24 V 14 (19) A | 30 V 11 A | 36 V 9.4 A | 48 V 7 A | ||
Input | Voltage [V] | AC85 to 264 1⌀ (Refer to the section 1.1 and section 3.2 of the instruction manual) *4 | |||||||||
Current [A] | ACIN 100 V | 2.7 typ (lo = 100%) | 4.1 typ (lo = 100%) | ||||||||
ACIN 200 V | 1.4 typ (lo = 100%) | 2.0 typ (lo = 100%) | |||||||||
Frequency [Hz] | 50/60 (47 to 63) | ||||||||||
Efficiency [%] | ACIN 100 V | 75.0 typ | 79.0 typ | 80.0 typ | 81.5 typ | 85.0 typ | 85.0 typ | 85.5 typ | 85.5 typ | 85.5 typ | |
ACIN 200 V | 77.0 typ | 82.5 typ | 83.0 typ | 84.5 typ | 88.0 typ | 88.0 typ | 88.0 typ | 88.0 typ | 88.0 typ | ||
Power rate (lo = 100%) | ACIN 100 V | 0.98 typ | 0.99 typ | ||||||||
ACIN 200 V | 0.92 typ | 0.95 typ | |||||||||
Inrush current [A] | ACIN 100 V | 15/30 typ (lo = 100%) (Primary inrush current value / secondary inrush current value) (Re-input interval of 3 seconds or more) | |||||||||
ACIN 200 V | 30/30 typ (lo = 100%) (Primary inrush current value / secondary inrush current value) (Re-input interval of 3 seconds or more) | ||||||||||
Leakage current [mA] | 0.45/0.75 max (According to each measurement method of 100 V/240 V AC Input 60 Hz, lo = 100%, IEC60950-1, the Electrical Appliances and Materials Safety Act) | ||||||||||
Output | Rated voltage [V] | 3.3 | 5 | 12 | 15 | 24 | 24 | 30 | 36 | 48 | |
Rated current [A]*5 | Natural air cooling | 40 | 40 | 17 | 14 | 12.5 | 12.5 (Peak 19) | 10 | 8.4 | 6.3 | |
Forced draft fan | 60 | 60 | 27 | 22 | 14 | 14 (Peak 19) | 11 | 9.4 | 7 | ||
Static input fluctuation [mV]*7 | 20 max | 20 max | 48 max | 60 max | 96 max | 96 max | 144 max | 144 max | 192 max | ||
Static load fluctuation [mV]*7 | 40 max | 40 max | 100 max | 120 max | 150 max | 150 max | 240 max | 240 max | 240 max | ||
Ripple [mVp · p] | 0 to +40°C ※2 | 80 max | 80 max | 120 max | 120 max | 120 max | 240 max | 150 max | 150 max | 150 max | |
-10 to 0°C ※2 | 140 max | 140 max | 160 max | 160 max | 160 max | 320 max | 200 max | 200 max | 200 max | ||
Ripple noise [mVp · p] | 0 to +40°C ※2 | 120 max | 120 max | 150 max | 150 max | 150 max | 300 max | 250 max | 250 max | 250 max | |
-10 to 0°C ※2 | 160 max | 160 max | 180 max | 180 max | 180 max | 360 max | 300 max | 300 max | 300 max | ||
Ambient temperature fluctuation [mV] | 0 to +40°C | 50 max | 50 max | 120 max | 150 max | 240 max | 240 max | 360 max | 360 max | 480 max | |
-10 to +40°C | 60 max | 60 max | 150 max | 180 max | 290 max | 290 max | 450 max | 450 max | 600 max | ||
Drift over time [mV]*3 | 20 max | 20 max | 48 max | 60 max | 96 max | 96 max | 144 max | 144 max | 192 max | ||
Startup Time [ms] | 350 typ (100 V AC Input, lo = 100%) | ||||||||||
Retention time [ms] | 20 typ (100 V AC Input, lo = 100%) | ||||||||||
Variable voltage range [V] | 2.85 to 3.63 | 4.50 to 5.50 | 10.80 to 13.20 | 13.50 to 16.50 | 21.60 to 27.50 | 21.60 to 27.50 | 27.00 to 33.00 | 32.40 to 39.60 | 39.60 to 52.80 | ||
Voltage setting accuracy [V] | 3.30 to 3.40 | 5.00 to 5.15 | 12.00 to 12.48 | 15.00 to 15.60 | 24.00 to 24.96 | 24.00 to 24.96 | 30.00 to 31.20 | 36.00 to 37.44 | 48.00 to 49.92 | ||
Functions included | Overcurrent protection | It operates at 105% min of rated current (101% min of peak current if there is peak current) and automatically returns | |||||||||
Overvoltage protection [V] | 4.00 to 5.25 | 5.75 to 7.00 | 13.80 to 16.80 | 17.25 to 21.00 | 27.60 to 33.60 | 27.60 to 33.60 | 34.50 to 42.00 | 41.40 to 50.40 | 55.20 to 67.20 | ||
Operating indication | N/A | ||||||||||
Remote sensing | N/A | ||||||||||
Remote ON/OFF (RC) | Option (External drive power supply required) | ||||||||||
Dielectric strength | Input - output / RC *6 | 3,000 V AC 1-minute cutoff current = 10 mA, 500 V DC 50 MΩ min (Normal temperature, normal humidity) | |||||||||
Input - FG | 2,000 V AC 1-minute cutoff current = 10 mA, 500 V DC 50 MΩ min (Normal temperature, normal humidity) | ||||||||||
Output / RC - FG *6 | 500 V AC 1-minute cutoff current = 25 mA, 500 V DC 50 MΩ min (Normal temperature, normal humidity) | ||||||||||
Output - RC *6 | 100 V AC 1-minute cutoff current = 25 mA, 100 V DC 10 MΩ min (Normal temperature, normal humidity) | ||||||||||
Environment | Operating temperature and humidity *4 | -10 to +70°C, 20 to 90%RH (No condensation) (Refer to the section 3.2 of the instruction manual) | |||||||||
Storage temperature/humidity | -20 to +75°C, 20 to 90%RH (No condensation) | ||||||||||
Vibration | 10 to 55 Hz 19.6 m/s^2 (2 G) period 3 minutes X, Y, Z direction 1 hour each | ||||||||||
Impact | 196.1 m/s^2 (20 G) 11 ms X, Y, Z direction 1 time each | ||||||||||
Compatible standard | Safety Standard | UL60951-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178-acquired, the Electrical Appliances and Materials Safety Act compliant | |||||||||
Conducted Emissions | FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B compliant | ||||||||||
Harmonic current | IEC61000-3-2 (Class A) compliant *8 | ||||||||||
Structure | External dimensions / weight | 95 × 52.5 × 222 mm (W × H × D)(excluding terminal block) / 810 g max (With chassis and cover: 1,270 g max) | |||||||||
Cooling method | Natural air cooling / forced draft fan (Refer to the section 3.1 and section 3.2 of the instruction manual) *4 |
Circuit board starter type
— | Number of outputs | Series name | Release year | Main features | Safety Standard Environmentally friendly | |
---|---|---|---|---|---|---|
Circuit board starter type | Single | 1 | GHA | '13 | 3 × 5 inch external shape, compatible with medical electrical equipment, high power density with electric cooling function | UL and C-UL certified product / DEMKO certified product / CE marking compliant product |
'15 | - SNF: Option with fan | |||||
'16 | ||||||
1 | LMA | '14 | Compatible with medical electrical equipment, peak compatible | UL and C-UL certified product / DEMKO certified product / CE marking compliant product | ||
1 | LFP | '12 | Peak current compatible, LEP series compact version | UL and C-UL certified product / TUV certified product / CE marking compliant product | ||
'13 | ||||||
1 | LEP | '02 | Peak current compatible | UL and C-UL certified product / TUV certified product / CE marking compliant product | ||
1 | LFA | '09 | Circuit board starter type general-purpose power supply, LEA series compact version | UL and C-UL certified product / TUV certified product / CE marking compliant product | ||
'10 | ||||||
SPLFA | '11 | LFA series (with chassis and cover) PSE-acquired product | The Electrical Appliances and Materials Safety Act certified product | |||
1 | LEA | '99 | Circuit board starter type general-purpose power supply | UL and C-UL certified product / TUV certified product / CE marking compliant product | ||
1 | LDA | '94 | Circuit board starter type general-purpose power supply | UL and C-UL certified product / CSA certified product / TUV certified product / CE marking compliant product | ||
'95 | ||||||
'97 | UL certified product / C-UL certified product / TUV certified product / CE marking compliant product | |||||
1 | LGA | '08 | Input 100 V AC system circuit board starter type general-purpose power supply | UL and C-UL certified product / TUV certified product / CE marking compliant product | ||
Multi | 2 | LEB | '00 | LEA series 2-output type | UL and C-UL certified product / TUV certified product / CE marking compliant product | |
3 | LDC | '94 | LDA series 3-output type | UL and C-UL certified product / CSA certified product / TUV certified product / CE marking compliant product | ||
'95 | ||||||
2 | LB | '92 | Circuit board starter type 2-output power supply, low price has been achieved by limiting performance and functions | — | ||
Linear type | Single Multi | 1 | G | '75 | 100 V AC system input, linear power supply, ultra-low noise and low ripple | — |
2 | GW | '75 | G series 2-output type | — |
By using the same external shape and mounting as those of the 100 V AC (85 to 132 V) LGA series (output power 50 to 240 W), it is easy to replace even if the customer urgently requests 200 V AC compatibility.
In addition, by expanding the lineup with models from 10 to 305 W as a circuit board starter power supply, even if using multiple units, it is possible to arrange them in the same series.
Part Number |
---|
LFA300F-5-TY |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | RoHS | Output voltage (Single only) | Rated output current (single only) (A) | Maximum output power (W) | Voltage settings reliability (V) | Output voltage variation (V) |
---|---|---|---|---|---|---|---|---|---|---|
3,086,765 VND | 1 Piece(s) | 12 Day(s) or more | 10 | DC5V | 60 | 300 | 5 to 5.15 | 4.5 to 5.5 |
Loading...Tải…
Shape | Open frame | Output power(W) | 300 | Single/multi | Single |
---|---|---|---|---|---|
Input Voltage | AC-dedicated | Input/output terminal shape | Terminal Block | Safety standards | CE / UL / CUL / TUV / CSA |
Height(mm) | 52.5 | Width(mm) | 95 | Depth(mm) | 222 |
Input Voltage(V) | AC85 to 264 | Excess current protective circuit | Available | Excess voltage protective circuit | Available |
Terminal block type | Vertical | Other optional functions | With volume |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy