(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
A MELSECNET/H communication unit
The MELSECNET/H Communication Unit is a unit for using the GOT1000 series as a normal station (MELSECNET/H connection, MELSECNET/10 connection) of the MELSECNET/H network system (PC-to-PC network) and MELSECNET/10 network system (PC-to-PC network).
Product image of GT15-J71BR13
Product image of GT15-J71LP23-25
(Unit: mm)
GT15-J71BR13 dimensional drawing
GT15-J71LP23-25 dimensional drawing
Category | Communication unit | |
---|---|---|
Series | GOT1000 | |
Unit | MELSECNET/H Communication Unit | |
Product Type Name | GT15-J71BR13 | |
Applicable Standards | UL/cUL, CE(EMC), KC | |
Supported Models | GT27, GT25 (5.7 type, wide model, enhanced environmental resistance model are excluded), GT16, GT15 | |
Maximum Number of Link Points Used Per Network | LX/LY | 8,192 points |
LB | MELSECNET/H mode, MELSECNET/H expansion mode: 16,384 points, MELSECNET/10 mode: 8,192 points | |
LW | MELSECNET/H mode, MELSECNET/H expansion mode: 16,384 points, MELSECNET/10 mode: 8,192 points | |
Maximum Link Points Per Station | MELSECNET/H mode, MELSECNET/10 mode: {(B+Y)÷8+(2 × W)}≦2,000 bytes, MELSECNET/H Expansion mode: {(B+Y)÷8+(2 × W)}≦35,840 bytes | |
Communication Speed | 10 Mbps | |
Communication Method | Token bus method | |
Synchronization Method | Frame synchronization method | |
Transmission Path Type | Coaxial single bus | |
Total Extension Distance | 3C-2V: 300 m, 5C-2V: 500 m *Possible to extend up to 2.5 km by using a repeater unit (A6BR10, A6BR10-DC) | |
Distance Between Stations (Max.) | 3C-2V: 300 m, 5C-2V: 500 m | |
Accessible Network Range | Only the sequencer on MELSECNET/H and MELSECNET/10 to which the GOT is connected | |
Maximum Number of Groups | 0 (Group not specified) | |
Number of Connected Stations | 31 stations | |
RAS Function | Prevention of system failure due to migration of management station, diagnosis function of link line check of own station, abnormality detection by link special relay and register, various diagnosis functions | |
Transient Transfer | N-to-N intercommunication | |
Connection Cable | 3C-2V, 5C-2V equivalent products | |
Compatible Connector | BNC-P-3-NiCAu (for 3C-2V), BNC-P-5-NiCAu (for 5C-2V) (DDK Ltd.) equivalent products | |
Internal Current Consumption | 0.77 A | |
Weight | 0.19 kg |
Category | Communication unit | |
---|---|---|
Series | GOT1000 | |
Unit | MELSECNET/H Communication Unit | |
Product Type Name | GT15-J71LP23-25 | |
Supported Models | GT27, GT25 (5.7 type, wide model, enhanced environmental resistance model are excluded), GT16, GT15 | |
Maximum Number of Link Points Used Per Network | LX/LY | 8,192 points |
LB | MELSECNET/H mode, MELSECNET/H expansion mode: 16,384 points, MELSECNET/10 mode: 8,192 points | |
LW | MELSECNET/H mode, MELSECNET/H expansion mode: 16,384 points, MELSECNET/10 mode: 8,192 points | |
Maximum Link Points Per Station | MELSECNET/H mode, MELSECNET/10 mode: {(B+Y)÷8+(2 × W)}≦2,000 bytes, MELSECNET/H Expansion mode: {(B+Y)÷8+(2 × W)}≦35,840 bytes | |
Communication Speed | 10 Mbps / 25 Mbps | |
Communication Method | Token ring method | |
Synchronization Method | Frame synchronization method | |
Transmission Path Type | Optical duplex loop | |
Total Extension Distance | 30 km | |
Maximum Distance Between Stations | "At 25 Mbps" SI optical cable: 200 m, H-PCF optical cable: 400 m, Wide band H-PCF optical cable: 1 km, QSI optical cable: 1 km, "At 10 Mbps" SI optical cable: 500 m, H-PCF optical cable: 1 km, Wide band H-PCF optical cable: 1 km, QSI optical cable: 1 km | |
Network | Only the sequencer on MELSECNET/H and MELSECNET/10 to which the GOT is connected | |
Maximum Number of Groups | 0 (Group not specified) | |
Number of Connected Stations | 63 Stations | |
RAS Function | Prevention of system failure due to migration of management station, loopback function by abnormality detection and cable disconnection, diagnosis function of link line check of own station, abnormality detection by link special relay and register, various diagnosis functions | |
Transient Transfer | N-to-N intercommunication | |
Connection Cable | Optical Fiber Cable (User arranged product) | |
Compatible Connector | 2-core optical connector plug (User arranged product) | |
Internal Current Consumption | 0.56 A | |
Weight | 0.18 kg |
Part Number |
---|
GT15-J71LP23-25 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Communication Speed (bps) | Maximum Number of Connected Devices (Units) | Note |
---|---|---|---|---|---|---|---|
25,735,000 VND | 1 Piece(s) | Quote | 10M/25M | 63 | Unit for Use as a Normal Station (MELSECNET/ H Connection and MELSECNET/ 10 Connection) - Communication Speed:10 Mbps/ 25 Mbps, Total Extension Distance: 30 km, Number of Connecting Stations: 63 |
Loading...Tải…
Type | Communication Unit | Compatible Model | G15 / G16 |
---|
Please check the type/dimensions/specifications of the part GT15-J71LP23-25 in the GOT1000 MELSECNET/H Communication Unit series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần GT15-J71LP23-25 trong chuỗi GOT1000 MELSECNET/H Communication Unit.
Part Number |
---|
GT15-J71BR13 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to ShipSố ngày giao hàng | Communication Speed (bps) | Maximum Number of Connected Devices (Units) | Note |
---|---|---|---|---|---|---|---|
25,735,000 VND | 1 Piece(s) | Quote | 10M | 31 | Unit for Use as a Normal Station (MELSECNET/H Connection and MELSECNET/10 Connection) - Communication Speed: 10 Mbps, Total Extension Distance - 3C-2V: 300 m, 5C-2V: 500 m *Can be Extended up to 2.5 km via a Repeater Unit (A6BR10, A6BR10-DC), Number of Connection Terminals: 31 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy