(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
A temperature input unit for the versatile MELSEC-Q series
Number of Channels | 4 channels | |
---|---|---|
Output | Temperature Conversion Value | 16-bit signed binary (-2,000 to 8,500: value rounded to first decimal place×multiplied by 10) 32-bit signed binary (-200,000 to 850,000: value rounded to third decimal place×multiplied by 1,000) |
Scaling Value | 16-bit signed binary | |
Compatible Resistance Temperature Detector | Pt100, JPt100 | |
Temperature Measuring Range | Pt100 | -200 to 850°C |
JPt100 | -180 to 600°C | |
Range Switching | Pt100 | -20 to 120°C / -200 to 850°C |
JPt100 | -20 to 120°C / -180 to 600°C | |
Precision (Precision With Respect to Maximum Value of Selected Range) | Ambient Temperature: 25±5°C | ±0.08% |
Ambient Temperature: 0 to 55°C | ±0.25% | |
Resolution | 0.025°C | |
Output Current for Temperature Detection | 1 mA | |
Conversion Speed | 40 ms / channel | |
Number of Analog Input Points | 4 points (4 channels) | |
Insulation Method | Between temperature-sensing resistance input and sequencer power supply: opto-isolator Between temperature measuring resistor input channels: non-insulated | |
Dielectric Strength | Between platinum resistance temperature detector input and sequencer power supply: 1,780 V AC rms / 3 cycles (altitude 2,000 m) | |
Insulation Resistance | Between platinumtemperature-sensing resistance input and sequencer power supply: 10 MΩor more at 500 V DC | |
Disconnection Detection | Yes (Independently for each channel) | |
External Wiring Connection Method | 18-point screw terminal block (M3 screw) | |
Number of Occupied Inputs/Outputs | 16 points (I/O assignment: intelligent 16 points) | |
5 V DC Internal Current Consumption | 0.60 A | |
External Dimensions | Height (H) | 98 mm |
Width (W) | 27.4 mm | |
Depth (D) | 90 mm | |
Weight | 0.17 kg |
Number of Channels | 4 channels | ||
---|---|---|---|
Output | Temperature Conversion Value | 16-bit signed binary (-2,000 to 8,500: value rounded to first decimal place×multiplied by 10) 32-bit signed binary (-200,000 to 850,000: value rounded to third decimal place×multiplied by 1,000) | |
Scaling Value | 16-bit signed binary | ||
Compatible Resistance Temperature Detector | Pt100, JPt100, Ni100 | ||
Temperature Measuring Range | Pt100 | -200 to 850°C | |
JPt100 | -180 to 600°C | ||
Ni100 | -60 to 180°C | ||
Range Switching | Pt100 | -20 to 120°C / 0 to 200°C / -200 to 850°C | |
JPt100 | -20 to 120°C / 0 to 200°C / -180 to 600°C | ||
Ni100 | - | ||
Precision (Precision With Respect to Maximum Value of Selected Range) | Reference Precision | ±Within 0.04% | |
Temperature Coefficient | Pt100/JPt100 (-20 to 120°C) | ±70 ppm/°C (±0.0070%/°C) | |
Pt100/JPt100 (0 to 200°C) | ±65 ppm/°C (±0.0065%/°C) | ||
Pt100/JPt100 (-200 to 850°C) | ±50 ppm/°C (±0.0050%/°C) | ||
Ni100 (-60 to 180°C) | ±70 ppm/°C (±0.0070%/°C) | ||
Resolution | 0.025°C | ||
Output Current for Temperature Detection | 1 mA | ||
Conversion Speed | 40 ms / channel | ||
Number of Analog Input Points | 4 points (4 channels) | ||
Insulation Method | Between temperature-sensing resistance input and sequencer power supply: opto-isolator insulation Between temperature-sensing resistance input channels: transformer insulation | ||
Dielectric Strength | Between temperature-sensing resistance input and sequencer power supply, between temperature measuring resistor input channels: 1,780 V AC rms / 3 cycles (altitude 2,000 m) | ||
Insulation Resistance | Between resistance temperature detector input and sequencer power supply, between resistance temperature detector input channels: 10 MΩor more at 500 V DC | ||
Disconnection Detection | Yes (Independently for each channel) | ||
External Wiring Connection Method | 18-point screw terminal block (M3 screw) | ||
Number of Occupied Inputs/Outputs | 16 points (I/O assignment: intelligent 16 points) | ||
5 V DC Internal Current Consumption | 0.62 A | ||
External Dimensions | Height (H) | 98 mm | |
Width (W) | 27.4 mm | ||
Depth (D) | 112 mm | ||
Weight | 0.20 kg |
Number of Channels | 4 channels | ||
---|---|---|---|
Output | Temperature Conversion Value | 16-bit signed binary (-2,700 to 18,200: value rounded to first decimal place×multiplied by 10) | |
Scaling Value | 16-bit signed binary | ||
Compliant Standard for Thermocouple | JIS C1602-1995 | ||
Accuracy of Temperature Measuring Range | Thermocouple Type | Temperature Measuring Range | Conversion accuracy (ambient operating temperature 25±5°C) Temperature characteristics (per 1°C change in ambient operating temperature) Maximum temperature error at ambient temperature of 55°C Effect per 1Ωof wiring resistance |
B | 0 to 600°C | - | |
600 to 800°C | Conversion accuracy: ±3.0°C Temperature characteristics: ±0.4°C Maximum temperature error at ambient temperature of 55°C: ±13.0°C Effect per 1Ωof wiring resistance: 0.009°C/Ω | ||
800 to 1,700°C | Conversion accuracy: ±2.5°C Temperature characteristics: ±0.4°C Maximum temperature error at ambient temperature of 55°C: ±12.5°C Effect per 1Ωof wiring resistance: 0.008°C/Ω | ||
1,700 to 1,820°C | - | ||
R | -50 to 0°C | - | |
0 to 300°C | Conversion accuracy: ±2.5°C Temperature characteristics: ±0.4°C Maximum temperature error at ambient temperature of 55°C: ±12.5°C Effect per 1Ωof wiring resistance: 0.011°C/Ω | ||
300 to 1,600°C | Conversion accuracy: ±2.0°C Temperature characteristics: ±0.3°C Maximum temperature error at ambient temperature of 55°C: ±9.5°C Effect per 1Ωof wiring resistance: 0.006°C/Ω | ||
1,600 to 1,760°C | - | ||
S | -50 to 0°C | - | |
0 to 300°C | Conversion accuracy: ±2.5°C Temperature characteristics: ±0.4°C Maximum temperature error at ambient temperature of 55°C: ±12.5°C Effect per 1Ωof wiring resistance: 0.011°C/Ω | ||
300 to 1,600°C | Conversion accuracy: ±2.0°C Temperature characteristics: ±0.3°C Maximum temperature error at ambient temperature of 55°C: ±9.2°C Effect per 1Ωof wiring resistance: 0.006°C/Ω | ||
1,600 to 1,760°C | - | ||
K | -270 to -200°C | - | |
-200 to 0°C | Conversion accuracy: ±0.5°C or±0.5% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.2% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±11.0°C Effect per 1Ωof wiring resistance: 0.004°C/Ω | ||
0 to 1,200°C | Conversion accuracy: ±0.5°C or±0.25% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.02% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±9.0°C Effect per 1Ωof wiring resistance: 0.002°C/Ω | ||
1,200 to 1,370°C | - | ||
E | -270 to -200°C | - | |
-200 to 0°C | Conversion accuracy: ±0.5°C or ±0.5% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.15% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±8.5°C Effect per 1Ωof wiring resistance: 0.003°C/Ω | ||
0 to 900°C | Conversion accuracy: ±0.5°C or±0.25% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.02% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±6.75°C Effect per 1 Ω of wiring resistance: 0.001°C/Ω | ||
900 to 1,000°C | - | ||
J | -210 to -40°C | - | |
-40 to 750°C | Conversion accuracy: ±0.5°C or±0.25% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.02% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±5.625°C Effect per 1Ωof wiring resistance: 0.002°C/Ω | ||
750 to 1,200°C | - | ||
T | -270 to -200°C | - | |
-200 to 0°C | Conversion accuracy: ±0.5°C or±0.5% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.1% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±6.0°C Effect per 1Ωof wiring resistance: 0.004°C/Ω | ||
0 to 350°C | Conversion accuracy: ±0.5°C or±0.25% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.02% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±2.625°C Effect per 1Ωof wiring resistance: 0.002°C/Ω | ||
350 to 400°C | - | ||
N | -270 to -200°C | - | |
-200 to 0°C | Conversion accuracy: ±0.5°C or±0.5% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.2% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±11.0°C Effect per 1Ωof wiring resistance: 0.006°C/Ω | ||
0 to 1,250°C | Conversion accuracy: ±0.5°C or±0.25% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.02% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±9.375°C Effect per 1Ωof wiring resistance: 0.003°C/Ω | ||
1,250 to 1,300°C | - | ||
Cold Contact Temperature Compensation Accuracy | ±1.0°C | ||
Overall Accuracy | (Overall accuracy) = (Conversion accuracy) + (Temperature characteristics)×(Ambient operating temperature change) + (Cold contact temperature compensation accuracy) *Ambient operating temperature change: Ambient operating temperature outside the range of 25±5°C | ||
Resolution | B, R, S, N: 0.3°C K, E, J, T: 0.1°C | ||
Conversion Speed | 40 ms / channel | ||
Number of Analog Input Points | 4 points (4 channels + Cold contact compensation channel) | ||
Insulation Method | Between thermocouple input and sequencer power supply: transformer insulation Between thermocouple input channels: transformer insulation Between cold contact compensation input (Pt100) and sequencer power supply: non-insulated | ||
Dielectric Strength | Between thermocouple input and sequencer power supply, between thermocouple input channels: 1,780 V AC rms / 3 cycles (altitude 2,000 m) | ||
Insulation Resistance | Between thermocouple input and sequencer power supply: 100 MΩor more at 500 V DC Between thermocouple input channels: 10 MΩor more at 500 V DC | ||
Disconnection Detection | Yes (Independently for each channel) | ||
External Wiring Connection Method | 18-point screw terminal block (M3 screw) | ||
Number of Occupied Inputs/Outputs | 16 points (I/O assignment: intelligent 16 points) | ||
5 V DC Internal Current Consumption | 0.50 A | ||
External Dimensions | Height (H) | 98 mm | |
Width (W) | 27.4 mm | ||
Depth (D) | 112 mm | ||
Weight | 0.25 kg |
Number of Channels | 8 channels | ||
---|---|---|---|
Output | Temperature Conversion Value | 16-bit signed binary (-2,000 to 8,500) | |
Scaling Value | 16-bit signed binary | ||
Compatible Resistance Temperature Detector | Pt100, JPt100, Ni100 | ||
Temperature Measuring Range | Pt100 | -200 to 850°C | |
JPt100 | -180 to 600°C | ||
Ni100 | -60 to 180°C | ||
Conversion Accuracy | Pt100 | -200 to 850°C | ±0.8°C (Ambient Temperature: 25±5°C) ±2.4°C (Ambient Temperature: 0 to 55°C) |
-20 to 120°C | ±0.3°C (Ambient Temperature: 25±5°C) ±1.1°C (Ambient Temperature: 0 to 55°C) | ||
0 to 200°C | ±0.4°C (Ambient Temperature: 25±5°C) ±1.2°C (Ambient Temperature: 0 to 55°C) | ||
JPt100 | -180 to 600°C | ±0.8°C (Ambient Temperature: 25±5°C) ±2.4°C (Ambient Temperature: 0 to 55°C) | |
-20 to 120°C | ±0.3°C (Ambient Temperature: 25±5°C) ±1.1°C (Ambient Temperature: 0 to 55°C) | ||
0 to 200°C | ±0.4°C (Ambient Temperature: 25±5°C) ±1.2°C (Ambient Temperature: 0 to 55°C) | ||
Ni100 | -60 to 180°C | ±0.4°C (Ambient Temperature: 25±5°C) ±1.2°C (Ambient Temperature: 0 to 55°C) | |
Resolution | 0.1°C | ||
Output Current for Temperature Detection | 1.0 mA or less | ||
Conversion Speed | 320 ms / 8 channels | ||
Number of Analog Input Points | 8 points (8 channels) | ||
Insulation Method | Between temperature-sensing resistance input and sequencer power supply, between temperature-sensing resistance input channels: transformer insulation | ||
Dielectric Strength | Between temperature-sensing resistance input and sequencer power supply: 500 V AC rms for 1 minute Between temperature measuring resistor input channels: 1,000 V AC rms for 1 min | ||
Insulation Resistance | Between resistance temperature detector input and sequencer power supply, between resistance temperature detector input channels: 10 MΩor more at 500 V DC | ||
Disconnection Detection | Yes (Independently for each channel) | ||
External Wiring Connection Method | 40-pin connector | ||
Compatible Connector | A6CON1, A6CON2, A6CON4 (sold separately) | ||
Number of Occupied Inputs/Outputs | 16 points (I/O assignment: intelligent 16 points) | ||
5 V DC Internal Current Consumption | 0.54 A | ||
External Dimensions | Height (H) | 102 mm | |
Width (W) | 27.4 mm | ||
Depth (D) | 130 mm | ||
Weight | 0.20 kg |
Number of Channels | 8 channels | ||
---|---|---|---|
Output | Temperature Conversion Value | 16-bit signed binary (-2,700 to 18,200) | |
Scaling Value | 16-bit signed binary | ||
Compliant Standard for Thermocouple | JIS C1602-1995, IEC60584-1(1995), IEC60584-2(1982) | ||
Accuracy of Temperature Measuring Range | Thermocouple Type | Temperature Measuring Range | Conversion accuracy (ambient operating temperature 25±5°C) Temperature characteristics (per 1°C change in ambient operating temperature) Maximum temperature error at ambient temperature of 55°C |
B | 0 to 600°C | - | |
600 to 800°C | Conversion accuracy: ±3.0°C Temperature characteristics: ±0.4°C Maximum temperature error at ambient temperature of 55°C: ±13.0°C | ||
800 to 1,700°C | Conversion accuracy: ±2.5°C Temperature characteristics: ±0.4°C Maximum temperature error at ambient temperature of 55°C: ±12.5°C | ||
1,700 to 1,820°C | - | ||
R | -50 to 0°C | - | |
0 to 300°C | Conversion accuracy: ±2.5°C Temperature characteristics: ±0.4°C Maximum temperature error at ambient temperature of 55°C: ±12.5°C | ||
300 to 1,600°C | Conversion accuracy: ±2.0°C Temperature characteristics: ±0.3°C Maximum temperature error at ambient temperature of 55°C: ±9.5°C | ||
1,600 to 1,760°C | - | ||
S | -50 to 0°C | - | |
0 to 300°C | Conversion accuracy: ±2.5°C Temperature characteristics: ±0.4°C Maximum temperature error at ambient temperature of 55°C: ±12.5°C | ||
300 to 1,600°C | Conversion accuracy: ±2.0°C Temperature characteristics: ±0.3°C Maximum temperature error at ambient temperature of 55°C: ±9.5°C | ||
1,600 to 1,760°C | - | ||
K | -270 to -200°C | - | |
-200 to 0°C | Conversion accuracy: ±0.5°C or±0.5% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.2% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±11.0°C | ||
0 to 1,200°C | Conversion accuracy: ±0.5°C or±0.25% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.02% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±9.0°C | ||
1,200 to 1,370°C | - | ||
E | -270 to -200°C | - | |
-200 to 0°C | Conversion accuracy: ±0.5°C or ±0.5% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.15% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±8.5°C | ||
0 to 900°C | Conversion accuracy: ±0.5°C or±0.25% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.02% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±6.75°C | ||
900 to 1,000°C | - | ||
J | -210 to -40°C | - | |
-40 to 750°C | Conversion accuracy: ±0.5°C or±0.25% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.02% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±5.625°C | ||
750 to 1,200°C | - | ||
T | -270 to -200°C | - | |
-200 to 0°C | Conversion accuracy: ±0.5°C or±0.5% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.1% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±6.0°C | ||
0 to 350°C | Conversion accuracy: ±0.5°C or±0.25% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.02% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±2.625°C | ||
350 to 400°C | - | ||
N | -270 to -200°C | - | |
-200 to 0°C | Conversion accuracy: ±0.5°C or±0.5% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.2% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±11.0°C | ||
0 to 1,250°C | Conversion accuracy: ±0.5°C or±0.25% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.02% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±9.375°C | ||
1,250 to 1,300°C | - | ||
Cold Contact Temperature Compensation Accuracy | ±1.0°C | ||
Overall Accuracy | (Overall accuracy) = (Conversion accuracy) + (Temperature characteristics)×(Ambient operating temperature change) + (Cold contact temperature compensation accuracy) *Ambient operating temperature change: Ambient operating temperature outside the range of 25±5°C | ||
Resolution | B, R, S, N: 0.3°C K, E, J, T: 0.1°C | ||
Sampling Cycle | 320 ms / 8 channels | ||
Conversion Speed | 320 ms / 8 channels | ||
Number of Analog Input Points | 8 points (8 channels + cold contact compensation channel) | ||
Insulation Method | Between thermocouple input channel and sequencer power supply: transformer insulation Between thermocouple input channels: transformer insulation Between cold contact compensation channel and sequencer power supply: non-insulated | ||
Dielectric Strength | Between thermocouple input channel and sequencer power supply: 500 V AC rms for 1 minute Between thermocouple input channels: 1,000 V AC rms for 1 minute | ||
Insulation Resistance | Between thermocouple input channel and sequencer power supply, between thermocouple input channels: 10 MΩor more at 500 V DC | ||
Disconnection Detection | N/A | ||
External Wiring Connection Method | 40-pin connector | ||
Compatible Connector | A6CON1, A6CON2, A6CON4 (sold separately) | ||
Number of Occupied Inputs/Outputs | 16 points (I/O assignment: intelligent 16 points) | ||
5 V DC Internal Current Consumption | 0.49 A | ||
External Dimensions | Height (H) | 98 mm | |
Width (W) | 27.4 mm | ||
Depth (D) | 90 mm | ||
Weight | 0.18 kg |
Number of Channels | 8 channels | ||
---|---|---|---|
Output | Temperature Conversion Value | 16-bit signed binary (-2,700 to 18,200) | |
Scaling Value | 16-bit signed binary | ||
Compliant Standard for Thermocouple | JIS C1602-1995, IEC60584-1(1995), IEC60584-2(1982) | ||
Accuracy of Temperature Measuring Range | Thermocouple Type | Temperature Measuring Range | Conversion accuracy (ambient operating temperature 25±5°C) Temperature characteristics (per 1°C change in ambient operating temperature) Maximum temperature error at ambient temperature of 55°C |
B | 0 to 600°C | - | |
600 to 800°C | Conversion accuracy: ±3.0°C Temperature characteristics: ±0.4°C Maximum temperature error at ambient temperature of 55°C: ±13.0°C | ||
800 to 1,700°C | Conversion accuracy: ±2.5°C Temperature characteristics: ±0.4°C Maximum temperature error at ambient temperature of 55°C: ±12.5°C | ||
1,700 to 1,820°C | - | ||
R | -50 to 0°C | - | |
0 to 300°C | Conversion accuracy: ±2.5°C Temperature characteristics: ±0.4°C Maximum temperature error at ambient temperature of 55°C: ±12.5°C | ||
300 to 1,600°C | Conversion accuracy: ±2.0°C Temperature characteristics: ±0.3°C Maximum temperature error at ambient temperature of 55°C: ±9.5°C | ||
1,600 to 1,760°C | - | ||
S | -50 to 0°C | - | |
0 to 300°C | Conversion accuracy: ±2.5°C Temperature characteristics: ±0.4°C Maximum temperature error at ambient temperature of 55°C: ±12.5°C | ||
300 to 1,600°C | Conversion accuracy: ±2.0°C Temperature characteristics: ±0.3°C Maximum temperature error at ambient temperature of 55°C: ±9.5°C | ||
1,600 to 1,760°C | - | ||
K | -270 to -200°C | - | |
-200 to 0°C | Conversion accuracy: ±0.5°C or±0.5% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.2% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±11.0°C | ||
0 to 1,200°C | Conversion accuracy: ±0.5°C or±0.25% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.02% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±9.0°C | ||
1,200 to 1,370°C | - | ||
E | -270 to -200°C | - | |
-200 to 0°C | Conversion accuracy: ±0.5°C or ±0.5% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.15% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±8.5°C | ||
0 to 900°C | Conversion accuracy: ±0.5°C or±0.25% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.02% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±6.75°C | ||
900 to 1,000°C | - | ||
J | -210 to -40°C | - | |
-40 to 750°C | Conversion accuracy: ±0.5°C or±0.25% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.02% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±5.625°C | ||
750 to 1,200°C | - | ||
T | -270 to -200°C | - | |
-200 to 0°C | Conversion accuracy: ±0.5°C or±0.5% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.1% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±6.0°C | ||
0 to 350°C | Conversion accuracy: ±0.5°C or±0.25% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.02% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±2.625°C | ||
350 to 400°C | - | ||
N | -270 to -200°C | - | |
-200 to 0°C | Conversion accuracy: ±0.5°C or±0.5% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.2% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±11.0°C | ||
0 to 1,250°C | Conversion accuracy: ±0.5°C or±0.25% of the measured temperature, whichever is greater Temperature characteristics: ±0.06°C or ±0.02% of the measured temperature, whichever is greater Maximum temperature error at ambient temperature of 55°C: ±9.375°C | ||
1,250 to 1,300°C | - | ||
Cold Contact Temperature Compensation Accuracy | ±1.0°C | ||
Overall Accuracy | (Overall accuracy) = (Conversion accuracy) + (Temperature characteristics)×(Ambient operating temperature change) + (Cold contact temperature compensation accuracy) *Ambient operating temperature change: Ambient operating temperature outside the range of 25±5°C | ||
Resolution | B, R, S, N: 0.3°C K, E, J, T: 0.1°C | ||
Sampling Cycle | 20 ms / 8 channels | ||
Conversion Speed | 640 ms / 8 channels | ||
Number of Analog Input Points | 8 points (8 channels + cold contact compensation channel) | ||
Insulation Method | Between thermocouple input channel and sequencer power supply: transformer insulation Between thermocouple input channels: transformer insulation Between cold contact compensation channel and sequencer power supply: non-insulated | ||
Dielectric Strength | Between thermocouple input channel and sequencer power supply: 500 V AC rms for 1 minute Between thermocouple input channels: 1,000 V AC rms for 1 minute | ||
Insulation Resistance | Between thermocouple input channel and sequencer power supply, between thermocouple input channels: 10 MΩor more at 500 V DC | ||
Disconnection Detection | Yes (Independently for each channel) | ||
External Wiring Connection Method | 40-pin connector | ||
Compatible Connector | A6CON1, A6CON2, A6CON4 (sold separately) | ||
Number of Occupied Inputs/Outputs | 16 points (I/O assignment: intelligent 16 points) | ||
5 V DC Internal Current Consumption | 0.65 A | ||
External Dimensions | Height (H) | 102 mm | |
Width (W) | 27.4 mm | ||
Depth (D) | 130 mm | ||
Weight | 0.22 kg |
Number of Channels | 4 channels | ||
---|---|---|---|
Output | Temperature Conversion Value | 16-bit signed binary (-2,700 to 18,200: value rounded to first decimal place×multiplied by 10) | |
Scaling Value | 16-bit signed binary | ||
Microvoltage Conversion Value | 16-bit signed binary (-25,000 to 25,000) | ||
Compliant Standard for Thermocouple | JIS C1602-1995 | ||
Accuracy of Temperature Measuring Range | Thermocouple Type | Temperature Measuring Range | Conversion accuracy (ambient operating temperature 25±5°C) Temperature characteristics (per 1°C change in ambient operating temperature) Maximum temperature error at ambient temperature of 55°C Effect per 1Ωof wiring resistance |
B | 0 to 600°C | - | |
600 to 800°C | Conversion accuracy: ±4.0°C Temperature characteristics: ±0.4°C Maximum temperature error at ambient temperature of 55°C: ±14.0°C Effect per 1Ωof wiring resistance: 0.011°C/Ω | ||
800 to 1,700°C | Conversion accuracy: ±3.5°C Temperature characteristics: ±0.4°C Maximum temperature error at ambient temperature of 55°C: ±13.5°C Effect per 1Ωof wiring resistance: 0.010°C/Ω | ||
1,700 to 1,820°C | - | ||
R | -50 to 0°C | - | |
0 to 300°C | Conversion accuracy: ±4.0°C Temperature characteristics: ±0.4°C Maximum temperature error at ambient temperature of 55°C: ±14.0°C Effect per 1Ωof wiring resistance: 0.013°C/Ω | ||
300 to 1,600°C | Conversion accuracy: ±3.5°C Temperature characteristics: ±0.4°C Maximum temperature error at ambient temperature of 55°C: ±13.5°C Effect per 1Ωof wiring resistance: 0.008°C/Ω | ||
1,600 to 1,760°C | - | ||
S | -50 to 0°C | - | |
0 to 300°C | Conversion accuracy: ±4.0°C Temperature characteristics: ±0.4°C Maximum temperature error at ambient temperature of 55°C: ±14.0°C Effect per 1Ωof wiring resistance: 0.013°C/Ω | ||
300 to 1,600°C | Conversion accuracy: ±3.5°C Temperature characteristics: ±0.4°C Maximum temperature error at ambient temperature of 55°C: ±13.5°C Effect per 1Ωof wiring resistance: 0.008°C/Ω | ||
1,600 to 1,760°C | - | ||
K | -270 to -200°C | - | |
-200 to 0°C | Conversion accuracy: ±2.0°C Temperature characteristics: ±0.25°C Maximum temperature error at ambient temperature of 55°C: ±8.25°C Effect per 1Ωof wiring resistance: 0.005°C/Ω | ||
0 to 200°C | Conversion accuracy: ±1.5°C Temperature characteristics: ±0.25°C Maximum temperature error at ambient temperature of 55°C: ±7.75°C Effect per 1Ωof wiring resistance: 0.002°C/Ω | ||
200 to 1,200°C | Conversion accuracy: ±2.0°C Temperature characteristics: ±0.25°C Maximum temperature error at ambient temperature of 55°C: ±8.25°C Effect per 1Ωof wiring resistance: 0.002°C/Ω | ||
1,200 to 1,370°C | - | ||
E | -270 to -200°C | - | |
-200 to 200°C | Conversion accuracy: ±1.5°C Temperature characteristics: ±0.15°C Maximum temperature error at ambient temperature of 55°C: ±5.25°C Effect per 1Ωof wiring resistance: 0.003°C/Ω | ||
200 to 900°C | Conversion accuracy: ±2.0°C Temperature characteristics: ±0.15°C Maximum temperature error at ambient temperature of 55°C: ±5.75°C Effect per 1Ωof wiring resistance: 0.001°C/Ω | ||
900 to 1,000°C | - | ||
J | -210 to -40°C | - | |
-40 to 200°C | Conversion accuracy: ±1.5°C Temperature characteristics: ±0.15°C Maximum temperature error at ambient temperature of 55°C: ±5.25°C Effect per 1Ωof wiring resistance: 0.002°C/Ω | ||
200 to 750°C | Conversion accuracy: ±2.0°C Temperature characteristics: ±0.15°C Maximum temperature error at ambient temperature of 55°C: ±5.75°C Effect per 1Ωof wiring resistance: 0.002°C/Ω | ||
750 to 1,200°C | - | ||
T | -270 to -200°C | - | |
-200 to 0°C | Conversion accuracy: ±2.0°C Temperature characteristics: ±0.1°C Maximum temperature error at ambient temperature of 55°C: ±4.5°C Effect per 1Ωof wiring resistance: 0.004°C/Ω | ||
0 to 350°C | Conversion accuracy: ±1.5°C Temperature characteristics: ±0.1°C Maximum temperature error at ambient temperature of 55°C: ±4.0°C Effect per 1Ωof wiring resistance: 0.002°C/Ω | ||
350 to 400°C | - | ||
N | -270 to -200°C | - | |
-200 to 0°C | Conversion accuracy: ±2.5°C Temperature characteristics: ±0.25°C Maximum temperature error at ambient temperature of 55°C: ±8.75°C Effect per 1Ωof wiring resistance: 0.007°C/Ω | ||
0 to 200°C | Conversion accuracy: ±2.0°C Temperature characteristics: ±0.25°C Maximum temperature error at ambient temperature of 55°C: ±8.25°C Effect per 1Ωof wiring resistance: 0.003°C/Ω | ||
200 to 1,250°C | Conversion accuracy: ±2.5°C Temperature characteristics: ±0.25°C Maximum temperature error at ambient temperature of 55°C: ±8.75°C Effect per 1Ωof wiring resistance: 0.002°C/Ω | ||
1,250 to 1,300°C | - | ||
Cold Contact Temperature Compensation Accuracy | ±1.0°C | ||
Overall Accuracy | (Overall accuracy) = (Conversion accuracy) + (Temperature characteristics)×(Ambient operating temperature change) + (Cold contact temperature compensation accuracy) *Ambient operating temperature change: Ambient operating temperature outside the range of 25±5°C | ||
Resolution | B: 0.7°C R, S: 0.8°C K, T: 0.3°C E: 0.2°C J: 0.1°C N: 0.4°C | ||
Microvoltage Input | Input Range | -100 to +100 mV (Input resistance 2 MΩor more) | |
Accuracy | ±0.2 mV (ambient operating temperature: 25±5°C) ±0.8 mV (ambient operating temperature: 0 to 55°C) | ||
Resolution | 4μ V | ||
Absolute Maximum Input | ±5 V | ||
Sampling Cycle | 20 ms / channel | ||
Conversion Speed | Sampling cycle×3 | ||
Number of Analog Input Points | 4 points (4 channels + Cold contact compensation channel) | ||
Insulation Method | Between thermocouple input / microvoltage input and sequencer power supply: transformer insulation Between thermocouple input / microvoltage input channels: transformer insulation Between cold contact compensation input (Pt100) and sequencer power supply: non-insulated | ||
Dielectric Strength | Between thermocouple input / microvoltage input and sequencer power supply, between thermocouple input / microvoltage input channels: 1,780 V AC rms / 3 cycles (altitude 2,000 m) | ||
Insulation Resistance | Between thermocouple input / microvoltage input and sequencer power supply: 100 MΩor more at 500 V DC Between thermocouple input / microvoltage input channels: 10 MΩor more 500 V DC | ||
Disconnection Detection | Yes (Independently for each channel) | ||
External Wiring Connection Method | 18-point screw terminal block (M3 screw) | ||
Number of Occupied Inputs/Outputs | 16 points (I/O assignment: intelligent 16 points) | ||
5 V DC Internal Current Consumption | 0.50 A | ||
External Dimensions | Height (H) | 98 mm | |
Width (W) | 27.4 mm | ||
Depth (D) | 112 mm | ||
Weight | 0.25 kg |
Part Number |
---|
Q64RD |
Q64RD-G |
Q64TD |
Q64TDV-GH |
Q68RD3-G |
Q68TD-G-H01 |
Q68TD-G-H02 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Number of Input Points (Number of Input CH) | Input I/F (Input Target) | Heater Burnout Detection Function | Sampling Cycle (Temperature Control) | Channel-to-channel isolation | Terminal shape | Temperature Conversion Speed |
---|---|---|---|---|---|---|---|---|---|---|---|
10,610,000 VND | 1 Piece(s) | Quote | 4 | Temperature Measuring Resistor | ○ | - | Non-Insulated | 18-point terminal block | 40ms/1ch | ||
13,791,250 VND | 1 Piece(s) | Quote | 4 | Temperature Measuring Resistor | ○ | - | Insulation | 18-point terminal block | 40ms/1ch | ||
12,730,000 VND | 1 Piece(s) | Quote | 4 | Thermocouple | ○ | - | Insulation | 18-point terminal block | 40ms/1ch | ||
12,730,000 VND | 1 Piece(s) | Quote | 4 | Thermocouple | ○ | 20ms/1ch | Insulation | 18-point terminal block | (Sampling Cycle × 3)/1 CH | ||
14,253,750 VND | 1 Piece(s) | Quote | 8 | Temperature Measuring Resistor | ○ | - | Insulation | 40-pin connector | 320ms/8ch | ||
14,253,750 VND | 1 Piece(s) | Quote | 8 | Thermocouple | × | 320ms/8ch | Insulation | 40-pin connector | 320ms/8ch | ||
15,916,250 VND | 1 Piece(s) | Quote | 8 | Thermocouple | ○ | 320ms/8ch | Insulation | 40-pin connector | 640ms/8ch |
Loading...Tải…
Type | Temperature control | Representative Standard | CE / UL |
---|
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy