(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Standard model MELSEC-L series CC-Link unit
LJ61BT11 image
Transmission Speed | 156 kbps / 625 kbps / 2.5 Mbps / 5 Mbps / 10 Mbps (Selectable) | ||
---|---|---|---|
Maximum Total Cable Extension (Maximum Transmission Distance) | Ver. 1.10 | At 156 kbps | 1,200 m |
At 625 kbps | 900 m | ||
At 2.5 Mbps | 400 m | ||
At 5 Mbps | 160 m | ||
At 10 Mbps | 100 m | ||
Station Type | Master Station (Ver. 1 Master Station or Ver. 2 Master Station) Local Station (Ver. 1 Local Station or Ver. 2 Local Station) | ||
Maximum Number of Connected Devices | Master Station | 64 devices | |
Number of Occupied Stations | Local Station | 1 to 4 stations | |
Maximum Link Points Per System | CC-Link Ver. 1 | Remote inputs/outputs (RX, RY): 2,048 points Remote registers (RWw): 256 points Remote registers (RWr): 256 points | |
CC-Link Ver. 2 | Remote inputs/outputs (RX, RY): 8,192 points Remote registers (RWw): 2,048 points Remote registers (RWr): 2,048 points | ||
Link Points Per Station | CC-Link Ver. 1 | Remote inputs/outputs (RX, RY): 32 points (30 points for local stations) Remote registers (RWw): 4 points Remote registers (RWr): 4 points | |
CC-Link Ver. 2 | Expanded Cyclic Setting: × 1 Setting | Remote inputs/outputs (RX, RY): 32 points (30 points for local stations) Remote registers (RWw): 4 points Remote registers (RWr): 4 points | |
Expanded Cyclic Setting: × 2 Setting | Remote inputs/outputs (RX, RY): 32 points (30 points for local stations) Remote registers (RWw): 8 points Remote registers (RWr): 8 points | ||
Expanded Cyclic Setting: × 4 Setting | Remote inputs/outputs (RX, RY): 64 points (62 points for local stations) Remote registers (RWw): 16 points Remote registers (RWr): 16 points | ||
Expanded Cyclic Setting: × 8 Setting | Remote inputs/outputs (RX, RY): 128 points (126 points for local stations) Remote registers (RWw): 32 points Remote registers (RWr): 32 points | ||
Communication Method | Broadcast polling method | ||
Synchronization Method | Frame synchronization method | ||
Encryption Method | NRZI (Non Return to Zero Inverted) sign | ||
Transmission Path Type | Bus (RS-485) | ||
Transmission Format | HDLC-compliant | ||
Error Control Method | CRC (X16 + X12 + X5 + 1) | ||
Communication Cable | CC-Link dedicated cable compatible with Ver. 1.10 | ||
Number of Occupied Inputs/Outputs | 32 points (I/O assignment: intelligent 32 points) | ||
5 V DC Internal Current Consumption | 0.46 A | ||
External Dimensions | Height (H) | 90 mm | |
Width (W) | 28.5 mm | ||
Depth (D) | 118 mm | ||
Weight | 0.15 kg |
Part Number |
---|
LJ61BT11 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng |
---|---|---|---|---|
4,982,500 VND | 1 Piece(s) | Quote |
Loading...Tải…
Please check the type/dimensions/specifications of the part LJ61BT11 in the MELSEC-L Series CC-Link Unit series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần LJ61BT11 trong chuỗi MELSEC-L Series CC-Link Unit.
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy