(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Long life for high frequency closing applications.
3-Contact Type | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Type Name | Standard | 3-Contact 2-Element Type | US-N5SS | US-N8SS | US-N20 | US-N30 | US-N40 | US-N50 | US-N70NS | US-N80NS | US-NH70NS | US-NH80NS |
3-Contact 3-Element Type | US-N5SSTE | US-N8SSTE | US-N20TE | US-N30TE | US-N40TE | US-N50TE | US-N70NSTE | US-N80NSTE | US-NH70NSTE | US-NH80NSTE | ||
With CAN Terminal | 3-Contact 2-Element Type | - | - | US-N20CX | US-N30CX | US-N40CX | US-N50CX | - | - | - | - | |
3-Contact 3-Element Type | - | - | US-N20TECX | US-N30TECX | US-N40TECX | US-N50TECX | - | - | - | - | ||
IEC 35 mm Rail Mounting | 3-Contact 2-Element Type | (Note 1) | (Note 1) | US-N20RM | - | - | - | - | - | - | - | |
3-Contact 3-Element Type | (Note 1) | (Note 1) | US-N20TERM | - | - | - | - | - | - | - | ||
Rating | Rated Operating Current (-10 To 40°C) (Note 2) | JEM (AC-1 Class) | 5 A | 8 A | 20 A | 30 A | 40 A | 50 A | 70 A | 80 A | 70 A | 80 A |
IEC (AC-51 Class) | 5 A | 8 A | 20 A | 30 A | 40 A | 50 A [45 A]Note 3 | 70 A | 80 A | 65 A | 75 A | ||
Applied Heater Capacity (-10 To 40°C) | 1 Ø 200 V (Note 4) | 1 kW | 1.6 kW | 4 kW | 6 kW | 8 kW | 10 kW [9 kW]Note 3 | 14 kW | 16 kW | 14 kW | 16 kW | |
3 Ø 200 V | 1.7 kW | 2.7 kW | 6.9 kW | 10.3 kW | 13.8 kW | 17.3 kW [15.5 kW]Note 3 | 24.2 kW | 27.7 kW | 24.2 kW | 27.7 kW | ||
1 Ø 400 V (Note 4) | - | - | 8 kW | 12 kW | 16 kW | 20 kW [18 kW]Note 3 | - | - | 28 kW | 32 kW | ||
3 Ø 400 V | - | - | 13.8 kW | 20.7 kW | 27.7 kW | 34.6 kW [31.1 kW]Note 3 | - | - | 48.5 kW | 55.4 kW | ||
Maximum Applicable Motor Capacity (Maximum Operating Current (Note 5)) | 3 Ø 200 V | 0.4 kW (3.2 A) | 0.4 kW (3.2 A) | 2.2 kW (11.1 A) | 3.7 kW (17.4 A) | 5.5 kW (26 A) | 5.5 kW (26 A) | 11 kW (48 A) | 11 kW (48 A) | 11 kW (48 A) | 11 kW (48 A) | |
3 Ø 400 V | - | - | 3.7 kW (8.7 A) | 7.5 kW (17.4 A) | 11 kW (26 A) | 11 kW (26 A) | - | - | 22 kW (48 A) | 22 kW (48 A) | ||
Minimum Load Current | 150 mA | 300 mA | ||||||||||
Main Circuit Specifications | Main Circuit Control Method | Batch control | ||||||||||
Rated Operating Voltage | 100 to 240 V AC 50/60 Hz | 100 to 480 V AC 50/60 Hz | 100 to 240 V AC 50/60 Hz | 200 to 480 V AC 50/60 Hz | ||||||||
Operating Voltage Range | 85 to 110% of rated operating voltage | |||||||||||
Rated Insulation Voltage | 250 V AC | 500 V AC | 250 V AC | 500 V AC | ||||||||
Voltage Drop Upon Closing | 1.5 V/phase | |||||||||||
Leakage Current When Closing | 15 mA or less (240 V AC 60 Hz) | 30 mA or less (480 V AC 60 Hz) | 30 mA or less (240 V AC 60 Hz) | 30 mA or less (480 V AC 60 Hz) | ||||||||
Surge On Current (60 Hz, Half-Wave 1 Cycle Wave Height Value) | 160 A | 800 A | 1,300 A | 1,800 A | ||||||||
Tolerance Ⅰ2t(A2S) | 106 | 2,600 | 7,000 | 13,500 | ||||||||
Trigger Method | Zero voltage trigger method | |||||||||||
Closing And Breaking Current Capacity | 32 A | 50 A | 111 A | 174 A | 260 A | 480 A | ||||||
Operating Circuit Specifications | Rated Operating Voltage | 12 to 24 V DC (voltage ripple rate 10% or less) | ||||||||||
Operating Voltage Fluctuation Range | 85 to 110% of rated operating voltage | |||||||||||
Operation Circuit Maximum Applied Voltage | 26.4 V DC | |||||||||||
Operation Circuit Voltage Input Current | 20 mA (12 to 24 V DC) | 5 mA (12 to 24 V DC) | 20 mA (12 to 24 V DC) | |||||||||
Input Impedance | 0.6 to 1.2 kΩ | 2.4 to 4.8 kΩ | 0.6 to 1.2 kΩ | |||||||||
Operating Voltage | 9 V DC or less | |||||||||||
Open Circuit Voltage | 3 V DC or more | |||||||||||
Response Time | Maximum 1 ms + 1/2 cycle | |||||||||||
Operating Display | Operating display LED indicator lamp (on when applying operating voltage) | |||||||||||
Cooling Fan Operating Voltage | - | 200 to 240 V AC 50/60 Hz | ||||||||||
Fan Fault Detection Output | Contact Configuration | - | b-Contact | |||||||||
Contact Capacity | - | 5 to 24 V DC/100 to 240 V AC 0.1 A | ||||||||||
Common Specifications | Withstand Voltage | 2 kV | 2.5 kV | 2 kV | 2.5 kV | |||||||
Insulation Resistance | 100 MΩ | |||||||||||
Rated Impulse Withstand Voltage (Note 6) | 4 kV | 6 kV | 4 kV | 6 kV | ||||||||
Ambient Operating Temperature | -10 to 60°C (At 40°C or higher, use reduced current) | |||||||||||
Relative Temperature | 45 to 85% RH | |||||||||||
Altitude | 2,000 m or less | |||||||||||
Vibration Resistance | 10 to 55 Hz 19.6 m/s2 | |||||||||||
Shock Resistance | 98 m/s2 |
Figure 1
Part Number |
---|
US-N40 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Dimension length (mm) | Dimension width (mm) | Dimension thickness (mm) | Specifications | Finger protection/terminal cover | Motor capacity 400 VAC (kW/A) | Motor Capacity VAC 200 (kW/A) | Number of Elements (Piece) | Rated current used (A) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
8,567,500 VND | 1 Piece(s) | Quote | 120 | 110 | 135 | Standard Form | NA | 11/26 | 5.5/26 | 2 | 40 |
Loading...Tải…
Operating Method | Irreversible type | Coil rated voltage(V) | DC 12–24 | Number of Poles | 3 |
---|---|---|---|---|---|
Representative Standard | CE / UL / TUV / CCC / CSA | Equipment Name | Solid state contactor |
Please check the type/dimensions/specifications of the part US-N40 in the Solid State Contactors US-N Series series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần US-N40 trong chuỗi Solid State Contactors US-N Series.
Part Number |
---|
US-N20TECX |
US-N20TERM |
US-N30 |
US-N40CX |
US-N40TE |
US-N40TECX |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to ShipSố ngày giao hàng | Dimension length (mm) | Dimension width (mm) | Dimension thickness (mm) | Specifications | Finger protection/terminal cover | Motor capacity 400 VAC (kW/A) | Motor Capacity VAC 200 (kW/A) | Number of Elements (Piece) | Rated current used (A) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6,601,250 VND | 1 Piece(s) | Quote | 100 | 90 | 107 | 3-pole 3-element form | With CAN terminal | 3.7/8.7 | 2.2/11.1 | 3 | 20 | ||
6,675,000 VND | 1 Piece(s) | Quote | 100 | 90 | 107 | 3-pole 3-element form: rail mounting dedicated | NA | 3.7/8.7 | 2.2/11.1 | 3 | 20 | ||
6,350,000 VND | 1 Piece(s) | Quote | 100 | 90 | 107 | Standard Form | NA | 7.5/17.4 | 3.7/17.4 | 2 | 30 | ||
10,818,750 VND | 1 Piece(s) | Quote | 120 | 110 | 135 | Standard Form | With CAN terminal | 11/26 | 5.5/26 | 2 | 40 | ||
10,818,750 VND | 1 Piece(s) | Quote | 120 | 110 | 135 | 3-pole 3-element form | NA | 11/26 | 5.5/26 | 3 | 40 | ||
8,832,500 VND | 1 Piece(s) | Quote | 120 | 110 | 135 | 3-pole 3-element form | With CAN terminal | 11/26 | 5.5/26 | 3 | 40 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy