(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Caution
thận trọng
Guide integrated cylinder with valve MVGQ series, valve for ø25 to ø63.
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | RoHS | Voltage | Number of Solenoids | Applicable Cylinder Dia. (Ø) | Pressure Rating (MPa) | Lead wire electrical entry | Manual | Indicator light / Surge voltage suppressor | Body options | Pilot port thread type | Speed Controller Specifications |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | DIN terminal / with connector | Non-locking, push type | Without indicator light / surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | DIN terminal / with connector | Locking type C (manually operated) | Without indicator light / surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | DIN terminal / with connector | Non-locking, push type | With surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | DIN terminal / with connector | Non-locking, push type | With indicator light and surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | DIN terminal / with connector | Locking type B (slotted) | With indicator light and surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | DIN terminal / with connector | Locking type C (manually operated) | With indicator light and surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | Grommet / lead length 300 mm | Non-locking, push type | Without indicator light / surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | Grommet / lead length 300 mm | Non-locking, push type | Without indicator light / surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-in | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | Grommet / lead length 300 mm | Locking type B (slotted) | Without indicator light / surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | Grommet / lead length 300 mm | Non-locking, push type | With surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | Grommet / lead length 300 mm | Non-locking, push type | With surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-in | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | Grommet / lead length 300 mm | Locking type C (manually operated) | With surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-in | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | Grommet / lead length 600 mm | Non-locking, push type | Without indicator light / surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | Grommet / lead length 600 mm | Non-locking, push type | With surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | L-type plug connector / with lead (300 mm in length) | Non-locking, push type | Without indicator light / surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | L-type plug connector / with lead (300 mm in length) | Non-locking, push type | Without indicator light / surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-in | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | L-type plug connector / with lead (300 mm in length) | Locking type C (manually operated) | Without indicator light / surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | L-type plug connector / without connector | Non-locking, push type | Without indicator light / surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | L-type plug connector / without connector | Non-locking, push type | With surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | L-type plug connector / without connector | Non-locking, push type | With indicator light and surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | L-type plug connector / with lead (300 mm in length) | Non-locking, push type | With surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | L-type plug connector / with lead (300 mm in length) | Locking type B (slotted) | With surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | L-type plug connector / with lead (300 mm in length) | Locking type B (slotted) | With indicator light and surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | L-type plug connector / with lead (300 mm in length) | Locking type C (manually operated) | With indicator light and surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | M-type plug connector / with lead (300 mm in length) | Non-locking, push type | Without indicator light / surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | M-type plug connector / with lead (300 mm in length) | Locking type B (slotted) | Without indicator light / surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-in | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | M-type plug connector / without connector | Non-locking, push type | Without indicator light / surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | M-type plug connector / without connector | Locking type C (manually operated) | Without indicator light / surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | M-type plug connector / without connector | Locking type C (manually operated) | With indicator light and surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | M-type plug connector / with lead (300 mm in length) | Non-locking, push type | With indicator light and surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | M-type plug connector / with lead (300 mm in length) | Locking type C (manually operated) | With indicator light and surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | DIN terminal / with connector | Non-locking, push type | With surge voltage suppressor | - | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | DIN terminal / with connector | Non-locking, push type | With indicator light and surge voltage suppressor | - | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | - | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | DIN terminal / with connector | Non-locking, push type | With indicator light and surge voltage suppressor | - | G | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | DIN terminal / with connector | Locking type B (slotted) | With indicator light and surge voltage suppressor | - | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | Grommet / lead length 300 mm | Non-locking, push type | Without indicator light / surge voltage suppressor | - | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | Grommet / lead length 300 mm | Non-locking, push type | With surge voltage suppressor | - | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | L-type plug connector / with lead (300 mm in length) | Non-locking, push type | Without indicator light / surge voltage suppressor | - | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | L-type plug connector / with lead (300 mm in length) | Locking type B (slotted) | With surge voltage suppressor | - | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | L-type plug connector / with lead (300 mm in length) | Non-locking, push type | With indicator light and surge voltage suppressor | - | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 40 or less | 0.15 to 0.7 | M-type plug connector / with lead (300 mm in length) | Non-locking, push type | With indicator light and surge voltage suppressor | - | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | Double | 40 or less | 0.1 to 0.7 | DIN terminal / with connector | Non-locking, push type | Without indicator light / surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | Double | 40 or less | 0.1 to 0.7 | DIN terminal / with connector | Non-locking, push type | With indicator light and surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | Double | 40 or less | 0.1 to 0.7 | Grommet / lead length 300 mm | Non-locking, push type | Without indicator light / surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | Double | 40 or less | 0.1 to 0.7 | Grommet / lead length 300 mm | Locking type B (slotted) | Without indicator light / surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | Double | 40 or less | 0.1 to 0.7 | Grommet / lead length 300 mm | Non-locking, push type | With surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | Double | 40 or less | 0.1 to 0.7 | Grommet / lead length 600 mm | Non-locking, push type | With surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | Double | 40 or less | 0.1 to 0.7 | L-type plug connector / with lead (300 mm in length) | Non-locking, push type | Without indicator light / surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | Double | 40 or less | 0.1 to 0.7 | L-type plug connector / without connector | Non-locking, push type | With indicator light and surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | Double | 40 or less | 0.1 to 0.7 | L-type plug connector / with lead (300 mm in length) | Non-locking, push type | With surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | Double | 40 or less | 0.1 to 0.7 | L-type plug connector / with lead (300 mm in length) | Non-locking, push type | With indicator light and surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | Double | 40 or less | 0.1 to 0.7 | L-type plug connector / with lead (300 mm in length) | Locking type B (slotted) | With indicator light and surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | Double | 40 or less | 0.1 to 0.7 | L-type plug connector / with lead (300 mm in length) | Locking type C (manually operated) | With indicator light and surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | Double | 40 or less | 0.1 to 0.7 | M-type plug connector / with lead (300 mm in length) | Non-locking, push type | Without indicator light / surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | Double | 40 or less | 0.1 to 0.7 | M-type plug connector / with lead (300 mm in length) | Locking type B (slotted) | Without indicator light / surge voltage suppressor | Individual pilot valve exhaust type | G | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | Double | 40 or less | 0.1 to 0.7 | M-type plug connector / with lead (300 mm in length) | Non-locking, push type | With indicator light and surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | Double | 40 or less | 0.1 to 0.7 | DIN terminal / with connector | Non-locking, push type | With indicator light and surge voltage suppressor | - | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | Double | 40 or less | 0.1 to 0.7 | Grommet / lead length 300 mm | Non-locking, push type | Without indicator light / surge voltage suppressor | - | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | Double | 40 or less | 0.1 to 0.7 | Grommet / lead length 300 mm | Non-locking, push type | With surge voltage suppressor | - | Rc | Meter-out | ||
- | 1 Piece(s) | Quote | 10 | DC24V | [Single] Single | 50 or Less | 0.15 to 0.7 | DIN terminal / with connector | Non-locking, push type | Without indicator light / surge voltage suppressor | Individual pilot valve exhaust type | Rc | Meter-out |
Loading...Tải…
Number of Ports | 5-Port Valve | Application | Unit for Manifold Mounting | Switching Type | 2-Position Exhaust |
---|---|---|---|---|---|
Mounting Orientation | Manifold Base | Specifications | Lubrication Free | Status at Power Off | Self-Recovery (Spring Return) |
Plumbing | Sub-Base Plumbing | Type | Solenoid Valves | Driving Type | Pilot Type Spool |
Seal Type | Soft Seal | Pilot Air Supply | Internal |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy