(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Caution
thận trọng
[Features]
· Lightweight and compact
・ Cooling capability: 9 kW
・ Temperature stability: ±0.5℃
・ Setting Temperature Range: 5 to 35℃
・ Maximum operating ambient temperature: 45℃
・ Power supply: Three-phase 200 to 230 V AC, 380 to 415 V AC
Part Number |
---|
HRS090-A-40-M |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | RoHS | Type | Cooling Method | Piping thread type | Optional specifications | Power Supply Specification |
---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | 31 Day(s) | - | - | - | Rc | Compatible with deionized water (pure water) piping | Three-phase 380 to 415 V AC (50/60 Hz) |
Loading...Tải…
Cooling capacity | 9 kW | Cooling method | Air-cooled refrigeration type |
---|
Please check the type/dimensions/specifications of the part HRS090-A-40-M in the Circulating Fluid Temperature Controller, Thermo-Chiller, Standard Type, Air-Cooled, 200 V / 400 V Specifications, HRS090 Series series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần HRS090-A-40-M trong chuỗi Circulating Fluid Temperature Controller, Thermo-Chiller, Standard Type, Air-Cooled, 200 V / 400 V Specifications, HRS090 Series.
Part Number |
---|
HRS090-A-20-BJM |
HRS090-A-20-BJW |
HRS090-A-20-BM |
HRS090-AF-20 |
HRS090-AF-20-B |
HRS090-AF-20-BJ |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to ShipSố ngày giao hàng | RoHS | Type | Cooling Method | Piping thread type | Optional specifications | Power Supply Specification |
---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | 10 | - | - | Rc | With earth leakage circuit breaker,with automatic water supply, for deionized water (pure water) piping | Three-phase 200 V AC (50 Hz), Three-phase 200 to 230 V AC (60 Hz) | ||
- | 1 Piece(s) | Quote | 10 | - | - | Rc | With earth leakage circuit breaker / with automatic water supply / fixed SI unit | Three-phase 200 V AC (50 Hz), Three-phase 200 to 230 V AC (60 Hz) | ||
- | 1 Piece(s) | Quote | 10 | - | - | Rc | With earth leakage circuit breaker, for deionized water (pure water) piping | Three-phase 200 V AC (50 Hz), Three-phase 200 to 230 V AC (60 Hz) | ||
- | 1 Piece(s) | Quote | 10 | - | - | G (Rc-G conversion fitting included) | None | Three-phase 200 V AC (50 Hz), Three-phase 200 to 230 V AC (60 Hz) | ||
- | 1 Piece(s) | 31 Day(s) | - | - | - | G (Rc-G conversion fitting included) | With earth leakage circuit breaker | Three-phase 200 V AC (50 Hz), Three-phase 200 to 230 V AC (60 Hz) | ||
- | 1 Piece(s) | 31 Day(s) | - | - | - | G (Rc-G conversion fitting included) | With earth leakage circuit breaker, with automatic water supply | Three-phase 200 V AC (50 Hz), Three-phase 200 to 230 V AC (60 Hz) |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy