(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Caution
thận trọng
[Features]
· Air flow adjustment function added (IZF10R).
· High-speed ionization.
· Allows you to detect emitter contamination.
· Compact fan type with simple functions.
· Alarm function for reporting high voltage issues or maintenance warnings.
AC Adapter (IZF10/10R-CG1, IZF10/10R-CG2)
Input Voltage | 100 V AC to 240 V AC, 50/60 Hz |
---|---|
Output Voltage | 24 V DC |
Output Current | 1 A max |
Ambient Operating Temperature | 0 to 40°C, Stored: -20 to +65℃ |
Ambient Humidity | Operating, Stored: 10 to 90% RH (no condensation) |
Standards/Directive | CE/cUL |
Model | IZF10-□□ | IZF10-L-□□ | IZF10R-□□ | IZF10-P-□□ | IZF10-LP-□□ | IZF10R-P-□□ |
---|---|---|---|---|---|---|
Maximum Air Flow | 0.66 m3/min | 0.46 m3/min | 0.80 m3/min (max.) | 0.66 m3/min | 0.46 m3/min | 0.80 m3/min (max.) |
Ion Generation Method | Corona discharge type | |||||
Voltage Application Method | DC type | |||||
Applied Voltage | ±5 kV | |||||
Offset Voltage (Ion Balance)* | Within ±13 V | |||||
Power Supply Voltage | 21.6 to 26.4 V DC (Within 24 V DC ±10%) | |||||
Current Consumption | 220 mA or less | 140 mA or less | 270 mA or less | 250 mA or less | 170 mA or less | 270 mA or less |
Switch output | NPN open collector output Max. load current: 80 mA Residual voltage: 1 V or less (load current at 80 mA) Max. applied voltage: 26.4 V DC | NPN open collector output Max. load current: 150 mA Residual voltage: 1 V or less (load current at 150 mA) Max. applied voltage: 26.4 V DC | PNP open collector output Max. load current: 80 mA Residual voltage: 1 V or less (load current at 80 mA) | PNP open collector output Max. load current: 150 mA Residual voltage: 1 V or less (load current at 150 mA) | ||
Ambient temperature | Operating: 0 to 50°C, Stored: -10 to +60°C | |||||
Ambient humidity | Operating, Stored: 35 to 80% RH (no condensation) | |||||
Material | Case: ABS / Stainless steel, Emitter: Tungsten | |||||
Weight | 280 g (With bracket 360 g) | 260 g (With bracket 340 g) | 280 g (With bracket 360 g) | 260 g (With bracket 340 g) | ||
Standards/Directive | CE (EMC Directive: 2004/108/EC) | CE (EMC directive: 2014/30/EU) | CE (EMC Directive: 2004/108/EC) | CE (EMC directive: 2014/30/EU) |
*Based on ANSI/ESD-STM3.1-2006 standards
IZF10/IZF10R Series display function names and descriptions
No. | Name | Panel Display | Type | Description |
---|---|---|---|---|
1 | Power supply switch | - | Switch | Switches power ON and OFF. |
2 | Power supply indicator | - | LED (Green/Orange) | Lights up green when power is supplied and lights up orange when incorrect high voltage or output signal over current is detected. |
3 | Error indicator | ALARM | LED (Red) | Lights up red when incorrect high voltage of 100 ms or more is generated. |
4 | Maintenance indicator | NDL | LED (Green) | Lights up green when emitter is contaminated or worn. |
5 | Air flow adjustment* | BLOW SPEED | Rotary switch | Adjusts fan air flow. |
6 | Balance adjustment | - | Trimmer | Adjusts offset voltage (ion balance). |
7 | Power connector | - | Connector | Connects the power supply cable or AC adapter. |
*IZF10R only
Alarm name | Output signal at the time of alarm* | LED lighting | Operation after alarm generated | Description | Action to reset alarm after issue resolved |
---|---|---|---|---|---|
Incorrect high voltage | Error signal OFF (B Contact) | Power supply indicator (Orange) Error indicator (Red) | Stop | Incorrect high voltage discharge of 100 ms or more generated | Supply power again |
Output signal overcurrent | Overcurrent generation signal OFF | Power supply indicator (Orange) | Continue | Overcurrent generated on output circuit | Automatic reset |
Maintenance alarm | Maintenance signal ON (A-Contact) | Maintenance indicator (Green) | Continue | Static neutralization performance is reduced due to contamination or wear of the emitters | Supply power again |
*NPN/PNP open collector output
Location of number stamped on IZF10 connector
Pin No. | Signal Name | Description |
---|---|---|
1 | +24 V DC | Power supply connection. |
2 | 0 V | |
3 | F.G. | Ground terminal with a ground resistance of 100Ω or less to use as a reference electric potential of offset voltage. |
4 | Error Signal | Turns OFF when a high voltage abnormality or output signal overcurrent is detected (ON during normal operation). |
(Unit: mm)
IZF10 Series dimensional drawing
(Unit: mm)
IZF10R Series dimensional drawing
(Unit: mm)
IZF10/IZF10R Series dimensional drawing (side view)
(Unit: mm)
IZF10/IZF10R Series dimensional drawing (back view)
(Unit: mm)
IZF10/IZF10R Series dimensional drawing (top part)
(Unit: mm)
IZF10/IZF10R Series variable angles
(Unit: mm)
Dimensional drawing with bracket mounted
Part Number |
---|
IZF10-A1 |
IZF10-B1 |
IZF10-CG2 |
IZF10-CP |
IZF10-CPZ |
IZF10R-A1 |
IZF10R-CG1 |
IZF10R-CG2 |
IZF10R-CP |
IZF10R-CPZ |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | RoHS | Type | Indicators | Additional Function | Air Flow/Air Consumption Quantity (m3/min) | Ion Balance Adjusting Function | Power Supply | Options | Accessories/options: ordered separately | I/O specifications | Compatible |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2,081,000 VND | 1 Piece(s) | 32 Day(s) | - | Related Components | - | - | - | - | - | Accessories (ordered separately) | Cartridge case / without airflow adjustment function | - | IZF10 application | ||
543,000 VND | 1 Piece(s) | 32 Day(s) | - | Related Components | - | - | - | - | - | Accessories (ordered separately) | Bracket / without airflow adjustment function | - | IZF10 application | ||
1,991,000 VND | 1 Piece(s) | 4 Day(s) | - | Related Components | - | - | - | - | - | Accessories (ordered separately) | AC adapter (without AC cord) / without airflow adjustment function | - | IZF10 application | ||
950,000 VND | 1 Piece(s) | 32 Day(s) | - | Related Components | - | - | - | - | - | Accessories (ordered separately) | Power cable (3 m) / without airflow adjustment function | - | IZF10 application | ||
2,036,000 VND | 1 Piece(s) | 32 Day(s) | - | Related Components | - | - | - | - | - | Accessories (ordered separately) | Power cable (10 m) / without airflow adjustment function | - | IZF10 application | ||
2,262,000 VND | 1 Piece(s) | 32 Day(s) | - | Related Components | - | - | - | - | - | Accessories (ordered separately) | There is a cartridge case / airflow adjustment function | - | IZF10R applied | ||
2,398,000 VND | 1 Piece(s) | 32 Day(s) | - | Related Components | - | - | - | - | - | Accessories (ordered separately) | AC adapter (with AC cord) / with airflow adjustment function | - | IZF10R applied | ||
2,217,000 VND | 1 Piece(s) | 32 Day(s) | - | Related Components | - | - | - | - | - | Accessories (ordered separately) | AC adapter (without AC cord) / with airflow adjustment function | - | IZF10R applied | ||
- | 1 Piece(s) | Quote | - | Related Components | - | - | - | - | - | Accessories (ordered separately) | Power cable (3 m) / with airflow adjustment function | - | IZF10R applied | ||
- | 1 Piece(s) | Quote | - | Related Components | - | - | - | - | - | Accessories (ordered separately) | Power cable (10 m) / with airflow adjustment function | - | IZF10R applied |
Loading...Tải…
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy