(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Caution
thận trọng
[Features]
· A pressure switch function has been added to the gauge
· The pressure switch has a light to confirm operation
· The pressure gauge includes a limit indicator
· Used to confirm supply pressure
Pressure Gauge With Switch GP46 external appearance
Circuit example
Model | GP46 | ||
---|---|---|---|
Pressure gauge | Shape | Back side thread | |
Ambient and fluid temperature | -5 to +60°C (no freezing) | ||
Indicated pressure range | 0 to 1.0 MPa | ||
Port size*1 | R1/8, R1/4 (option M: with M5 female thread) | ||
Fluid*2*6 | Air | ||
Indication precision*7) | ±0.03 MPa | ||
Pressure switch | Setting range*3*4 | 0.1 to 0.8 MPa | |
Hysteresis | 0.07 MPa or less | ||
Pointer error*5 | ±0.05 MPa (5 to 40°C) ±0.08 MPa (-5 to +60°C) (no freezing) | ||
Contact | With light: 1a (normally open) Without light: 1ab (normally open / normally closed) | ||
Wiring | Lead wire: 300 mm long | ||
Indicator light | AC | Neon light | |
DC | Light-emitting diode (LED) | ||
Clear cover | Part number: G46-00-00-3 | ||
Attachment: with cover ring assembly | C | Part number: 1305104-4A | |
C2 | Part number: 1305104-10A | ||
Weight (kg) | 0.12 |
*1: When mounting the pressure gauge, take care not to over-tighten. Excessive tightening will cause damage. Use pipe tape for sealing.
*2: Water is not an acceptable fluid. Before using other fluids, please contact the manufacturer's support center as there may be a corrosion problem.
*3: The set value of the pressure switch is indicated by the pointer (green). It is the point where the circuit between N.O. (white) and COM (black) is turned off during pressure decrease. To set the value, turn the needle in the clockwise direction to the correct value. When setting, if the desired set position has been passed, turn the needle in the counterclockwise direction back again beyond the desired value and then set it again.
*4: Make sure to provide a minimum difference of 0.1 MPa between the set pressure and the operating pressure (including the pressure drop). If the difference is smaller, it could lead to improper operation. See the manufacturer's catalog for details on how to set the setting needle. Note that the operating pressure should be the sum of the pressure of the setting needle error (±0.03 MPa), the hysteresis (0.07 MPa), and the display accuracy (±0.05 MPa) on the set pressure value, or the circuit between N.O. (white) and COM (black) may not turn ON while pressure is increasing.
*5: Maximum error value: Add the pressure gauge indicator error to the setting needle error.
*6: Take care to avoid freezing. This may result in a malfunction.
*7: The guaranteed temperature range is 23°C±5°C.
Circuit diagram without indicator light
Circuit diagram with indicator light (top: 110, 220 V AC, bottom: 24 V DC)
*The arrow in the diagram indicates the direction of the pressure increase. The light turns off at or above the set pressure and turns on when it is below the set pressure.
Model | Pressure range*1 | Indication unit | Port size | Note |
---|---|---|---|---|
MPa | ||||
GP46-10-01 to 02 (-Q) | 0 to 1.0 | MPa | R 1/8 R 1/4 | - |
GP46-10-01 to 02L2 | ||||
GP46-10-01 to 02L5 (-Q) |
*1: Do not apply pressure more than the maximum display pressure. This may result in a malfunction.
Model | Pressure range*1 | Indication unit | Port size | Note | |
---|---|---|---|---|---|
MPa | psi | ||||
GP46-10-01 to 02-X201 | 0 to 1.0 | - | MPa | R 1/8 R 1/4 | Lead wire length 3 m |
GP46-10-01 to 02L2-X201 | |||||
GP46-10-01 to 02L5-X201 |
*1: Do not apply pressure more than the maximum display pressure. This may result in a malfunction.
Load | Load resistance | ||
---|---|---|---|
Rated voltage | 30 V DC | 125 V AC | 250 V AC |
Operating current range | 0.01 to 0.5 A | 0.01 to 0.3 A | 0.01 to 0.2 A |
*The dimensions within ( ) are for port size R1⁄4
(Unit: mm)
GP46-10-01 to 02 (M) (L2, 5) dimensional drawing
(Unit: mm)
With cover ring assembly (for panel mount) GP46-10-01 to 02 (M) (L2, 5)-C dimensional drawing
Method 1
(1) Before setting the limit indicator and the (green) setting needle, turn the cover counterclockwise (approximately 6 to 7 mm) until it stops. Then, remove by pulling it towards you.
Method 2
(2) Use a flat head screwdriver (with a 2.9‑mm blade width) to set the (green) limit indicator. Be careful not to bend the other needle or damage the dial plate.
Method 3
(3) Before setting the setting needle, use a flat head screwdriver (with a 2.9‑mm blade width) to turn the setting screw and set the setting needle to the set pressure.
Turning the screw
Method 4
(4) After completing the setting, replace the cover. Fit the cover by aligning the cutout in the cover to the groove on the top of the black case. Turn the cover clockwise (approximately 6 to 7 mm) until it stops. Make sure that the matching mark on the cover is aligned with the groove on the top of the case.
Part Number |
---|
GP46-10-02M |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | RoHS | Outer Diameter (φ) | Connection screw | Option | Special Configurations | Indication lamp addition symbol | Attachment |
---|---|---|---|---|---|---|---|---|---|---|---|
999,200 VND | 1 Piece(s) | 32 Day(s) | - | 42.5 | R1/4 | With M5 (female thread) | None | Without light | Without cover ring assembly |
Loading...Tải…
Type | Other Pressure Gauge / Peripheral Accessories | Maximum Indicated Pressure(Mpa) | 1 | Shape | Back side thread |
---|---|---|---|---|---|
Maximum Indicated Pressure | 1.0 MPa |
Please check the type/dimensions/specifications of the part GP46-10-02M in the Pressure Gauge With Switch GP46 Series series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần GP46-10-02M trong chuỗi Pressure Gauge With Switch GP46 Series.
Part Number |
---|
GP46-10-01-Q |
GP46-10-01-X201 |
GP46-10-01L2 |
GP46-10-02M-C2 |
GP46-10-02M-C2-X201 |
GP46-10-02ML2-C |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to ShipSố ngày giao hàng | RoHS | Outer Diameter (φ) | Connection screw | Option | Special Configurations | Indication lamp addition symbol | Attachment |
---|---|---|---|---|---|---|---|---|---|---|---|
1,321,600 VND | 1 Piece(s) | 32 Day(s) | - | 42.5 | R 1⁄8 | None | CE marked | Without light | Without cover ring assembly | ||
1,075,200 VND | 1 Piece(s) | 32 Day(s) | - | 42.5 | R 1⁄8 | None | Lead wire length 3 m | Without light | Without cover ring assembly | ||
977,600 VND | 1 Piece(s) | 32 Day(s) | - | 42.5 | R 1⁄8 | None | None | With neon light / 100 to 220 V AC common | Without cover ring assembly | ||
- | 1 Piece(s) | Quote | 10 | 57 | R 1/4 | With M5 (female thread) | None | Without light | Clear cover has protrusion (Clear cover is removable). The wrench flats protrude | ||
- | 1 Piece(s) | Quote | 10 | 57 | R 1/4 | With M5 (female thread) | Lead wire length 3 m | Without light | Clear cover has protrusion (Clear cover is removable). The wrench flats protrude | ||
1,082,400 VND | 1 Piece(s) | 32 Day(s) | - | 57 | R1/4 | With M5 (female thread) | None | With neon light / 100 to 220 V AC common | Clear cover has no protrusion (clear cover cannot be removed) |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy