(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Caution
thận trọng
Choose between single and double solenoids by using a switch.
[Features]
· Rated voltage: 24 V DC.
· Pilot valve option: Standard (0.7 MPa), Quick response (0.7 MPa).
· Back-pressure check valve (built-in valve type): Standard, built-in.
· Coil type: Standard, with power-saving circuit (continuous duty type).
· Common specifications: Non-polar, positive common, negative common.
5-Port Solenoid Valve With Single / Double Switching Function external appearance
Base mounted valve weight
Body ported valve weight
*This product is the valve unit only. The manifold is not included.
Single solenoid
Double solenoid
Switching between single specification and double specification (Left: single specification / actuation switch recessed, Right: double specification / actuation switch protruding)
Usage Precautions
(Unit: mm)
SY3(S, D)00 dimensional drawing
(Unit: mm)
SY5(S, D)00 dimensional drawing
(Unit: mm)
SY3(S, D)30 dimensional drawing
(Unit: mm)
SY5(S, D)30 dimensional drawing
*Dimensional drawings are of a representative product.
Part Number |
---|
SY3D00-5D1 |
SY3D00-5NZ1 |
SY3D00-5U1 |
SY3D00-5UD1 |
SY3D00-5UE1 |
SY3D00-5UF1 |
SY3D00-5Z1 |
SY3D00H-5U1 |
SY3S00-5D1 |
SY3S00-5U1 |
SY3S00-5UF1 |
SY3S00-5Z1 |
SY3S00-5ZF1 |
SY3S00H-5U1 |
SY3S30-5Z1-C4 |
SY3S30T-5ZF1-C6 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | RoHS | Number of Solenoids | Status at Power Off | Pipe Port Type | Applicable Cylinder Dia. (Ø) | Plumbing | Connecting Tube Diameter | Coil specifications | Manual | Indicator light / Surge voltage suppressor | Valve specifications | Functions | Back-pressure check valve | Common specifications |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | 10 | Double | Self-Retaining | - | 80 or Less | Sub-Base Plumbing | - | Standard | Push-turn locking screwdriver-operated type | None | SY3000 | Standard (0.7 MPa) | Standard | Non-polarized | ||
- | 1 Piece(s) | Quote | - | Double | Self-Retaining | - | 80 or Less | Sub-Base Plumbing | - | Standard | Non-locking, push type | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | Standard | Negative common | ||
- | 1 Piece(s) | Quote | - | Double | Self-Retaining | - | 80 or Less | Sub-Base Plumbing | - | Standard | Non-locking, push type | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | Standard | Non-polarized | ||
- | 1 Piece(s) | Quote | 10 | Double | Self-Retaining | - | 80 or Less | Sub-Base Plumbing | - | Standard | Push-turn locking screwdriver-operated type | With indicator light and surge voltage suppressor (non-polar type) | SY3000 | Standard (0.7 MPa) | Standard | Non-polarized | ||
- | 1 Piece(s) | Quote | - | Double | Self-Retaining | - | 80 or Less | Sub-Base Plumbing | - | Standard | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | Standard | Non-polarized | ||
- | 1 Piece(s) | Quote | - | Double | Self-Retaining | - | 80 or Less | Sub-Base Plumbing | - | Standard | Sliding type locking system | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | Standard | Non-polarized | ||
- | 1 Piece(s) | Quote | - | Double | Self-Retaining | - | 80 or Less | Sub-Base Plumbing | - | Standard | Non-locking, push type | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | Standard | Positive common | ||
- | 1 Piece(s) | Quote | - | Double | Self-Retaining | - | 80 or Less | Sub-Base Plumbing | - | Standard | Non-locking, push type | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | Built-in type | Non-polarized | ||
- | 1 Piece(s) | Quote | 10 | [Single] Single | Self-Recovery (Pressure Differential Return) | - | 80 or Less | Sub-Base Plumbing | - | Standard | Push-turn locking screwdriver-operated type | None | SY3000 | Standard (0.7 MPa) | Standard | Non-polarized | ||
- | 1 Piece(s) | Quote | - | [Single] Single | Self-Recovery (Pressure Differential Return) | - | 80 or Less | Sub-Base Plumbing | - | Standard | Non-locking, push type | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | Standard | Non-polarized | ||
- | 1 Piece(s) | Quote | - | [Single] Single | Self-Recovery (Pressure Differential Return) | - | 80 or Less | Sub-Base Plumbing | - | Standard | Sliding type locking system | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | Standard | Non-polarized | ||
- | 1 Piece(s) | Quote | - | [Single] Single | Self-Recovery (Pressure Differential Return) | - | 80 or Less | Sub-Base Plumbing | - | Standard | Non-locking, push type | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | Standard | Positive common | ||
- | 1 Piece(s) | Quote | 10 | [Single] Single | Self-Recovery (Pressure Differential Return) | - | 80 or Less | Sub-Base Plumbing | - | Standard | Sliding type locking system | With indicator light and surge voltage suppressor | SY3000 | Standard (0.7 MPa) | Standard | Positive common | ||
- | 1 Piece(s) | Quote | - | [Single] Single | Self-Recovery (Pressure Differential Return) | - | 80 or Less | Sub-Base Plumbing | - | Standard | Non-locking, push type | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | Built-in type | Non-polarized | ||
- | 1 Piece(s) | Quote | - | [Single] Single | Self-Recovery (Pressure Differential Return) | One-Touch Plumbing | 80 or Less | Direct Plumbing | Ø4 | Standard | Non-locking, push type | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | Standard | Positive common | ||
- | 1 Piece(s) | Quote | - | [Single] Single | Self-Recovery (Pressure Differential Return) | One-Touch Plumbing | 80 or Less | Direct Plumbing | Ø6 | With energy-saving circuit (long time continuous energizing type) | Sliding type locking system | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | Standard | Positive common |
Loading...Tải…
Type | Solenoid Valves | Application | Unit for Manifold Mounting | Number of Ports | 5-Port Valve |
---|---|---|---|---|---|
Mounting Orientation | Manifold Base | Specifications | Standard | Switching Type | 2-Position Exhaust |
Voltage | DC24V | Driving Type | Pilot Type Spool | Seal Type | Soft Seal |
Pressure Rating(MPa) | 0.5 | Pilot Air Supply | Internal | Mounting screw type | Small cross pan head screw |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy