(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Caution
thận trọng
A solenoid valve that is effective in preventing short-circuit accidents caused by foreign objects entering the connector.
[Features]
・ Power consumption: 0.1 W (With power saving circuit)
・ Connector with protective cover with dust-proof measures Ass'y
・ The cover is made of chloroprene rubber for electricity, which has excellent weather resistance and electrical insulation
(Do not allow it to get wet with cutting oil, etc. )
・ Clean external appearance due to the use of round cord
[10-Series, Clean Series]
・ It is suitable for clean environment
· It prevents dust generation in the cleanroom
3-Port Solenoid Valve, Direct Operated, Rubber Seal, V100 Series external appearance
V114 (A) and V124 (A) JIS symbols
Fluid | Air |
---|---|
Ambient Temperature and Operating Fluid Temperature °C | -10 to +50 (no freezing) |
*1Response Time (for DC) ms | ON: 5 or less, OFF: 4 or less |
Maximum Operating Frequency Hz | 20 |
Manual Operation | Non-locking push type, locking type screwdriver operated type (slotted) |
Lubrication | Not required |
Mounting Position | Free |
*2: Impact Resistance / Vibration Resistance: m/s2 | 150/30 |
Enclosure | Dust-proof |
*1: Based on JIS B 8419:2010 dynamic performance test. (Standard type: coil temperature of 20°C, at rated voltage, with no surge voltage suppressor)
*2: Impact resistance: No malfunctions after testing using an impact tester under the following conditions: in the axial direction and at a right angle to the armature in both energized and non-energized states (once for each condition state). (Initial value)
Vibration resistance: No malfunctions occurred in a 1-sweep test between 45 and 2,000 Hz. The test was performed in both energized and non-energized states and in the axial direction and at a right angle to the armature. (Initial value)
Series | V114/V124 | V114A/V124A | ||
---|---|---|---|---|
Electrical Entry | Grommet (G) / (H), L-shaped plug connector (L), M-shaped plug connector (M) | |||
Coil rated voltage (V) | DC | 24, 12, 6, 5, 3 | ||
AC 50/60 Hz | 100, 110, 200, 220 | - | ||
Allowable Voltage Fluctuation | -10 to +10%* | |||
Power Consumption W | DC | Standard: 0.35 (with light: 0.4), with energy-saving circuit: 0.1 *[startup: 0.4, holding: 0.1] | 1 W (with light: 1.1) | |
Apparent Power VA | AC | 100 V | 0.78 (with light: 0.81) | - |
110 V [115 V] | 0.86 (with light: 0.89) [0.94 (with light: 0.97)] | - | ||
200 V | 1.18 (with light: 1.22) | - | ||
220 V [230 V] | 1.30 (with light: 1.34) [1.42 (with light: 1.46)] | - | ||
Surge Voltage Suppressor | See the SMC catalog. | |||
Indicator Light | LED |
*Refer to the SMC catalog for details.
Valve Model Numbers | Switching Method | Type | Operating Pressure Range *4 (MPa) | When Using in Vacuum (MPa) *4 | Piping connection port diameter | Weight (g) *2 | |||
---|---|---|---|---|---|---|---|---|---|
Port 1 | 3-Port | Port 1, Port 3 | 2 port | Grommet Type | L Type, M Type | ||||
V114 | N.C. | Standard | 0 to 0.7 | -100 kPa to 0.6 | -100 kPa to 0 | M5 × 0.8 | M5 × 0.8 | V1□4: 13 (27) V1□4A: 16 (30) | Plug connector V1□4: 12 (26) V1□4A: 16 (29) |
V114A | N.C. | High flow rate | 0 to 0.7 | -100 kPa to 0.6 | -100 kPa to 0 | M5 × 0.8 | M5 × 0.8 | ||
V124*1 | N.C. | Standard | 0 to 0.7 | -100 kPa to 0 | -100 kPa to 0.6 | M5 × 0.8 | M5 × 0.8 | ||
V124A*1 | N.C. | High flow rate | 0 to 0.7 | -100 kPa to 0 | -100 kPa to 0.6 | M5 × 0.8 | M5 × 0.8 |
Valve Model Numbers | Flow Rate Characteristics | |||||
---|---|---|---|---|---|---|
1 → 2 [3 → 2 *3] | 2 → 3 [2 → 1 *3] | |||||
C [dm3/(s·bar)] | b | Cv | C [dm3/(s·bar)] | b | Cv | |
V114 | 0.037 | 0.11 | 0.008 | 0.054 | 0.35 | 0.015 |
V114A | 0.076 | 0.07 | 0.016 | 0.099 | 0.23 | 0.024 |
V124*1 | 0.054 | 0.35 | 0.015 | 0.037 | 0.11 | 0.008 |
V124A*1 | 0.099 | 0.23 | 0.024 | 0.076 | 0.07 | 0.016 |
*1: For V124 and V124A, apply pressure from port 3 and exhaust from port 1.
*2: Values in ( ) are with the subplate.
*3: For 10-V124 (A).
*4: When the difference between the primary and secondary sides is extremely small (guideline is 0.001 MPa or less), the quality of the air and lubricant oil in the solenoid valve (condensate mixture, etc.) may prevent air from being output or may cause the flow rate to dramatically decrease.
Structure Drawing
Number | Part name | Material |
---|---|---|
1 | Body | Resin |
2 | Cover | SUS |
3 | Push Rod | Resin |
4 | Armature Assembly | SUS, resin |
5 | Poppet | FKM |
6 | Return Spring | SUS |
7 | Poppet Spring | SUS |
8 | Coil Assembly | - |
9 | Manual | Resin |
Number | Part name | Part number | Material | Note |
---|---|---|---|---|
10 | Gasket Assembly | V100-31-1A | FKM, steel | Gasket, 2 screws |
11 | Sub-plate | V100-74-1 | Zinc diecast | - |
(Unit: mm)
Grommet (G), (H): V114/124 (A)-□G / H□□-M5 drawing
*Values in [ ] are for AC.
Values in < > are for the large flow capacity type (A).
(Unit: mm)
L-shaped plug connector (L): V114/124 )(A)-□L□□-M5 drawing
Other dimensions are the same as the grommet type.
(Unit: mm)
M type plug connector (M): V114/124 (A)-□M□□-M5 drawing
Other dimensions are the same as the grommet type.
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | RoHS | Application | Mounting Orientation | Specifications | Switching Type | Voltage | Pipe Port Type | Plumbing Thread Nominal | CV Value | Manual Switch | Coil specifications | Lead wire electrical entry | Manual | Indicator light / Surge voltage suppressor | Type | Applications |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC5V | M | M5 | 0.008 | - | 0.35 W | Grommet (lead wire length: 300 mm) | Non-locking, push type | With indicator light / surge voltage suppressor (non-polarized) | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC5V | M | M5 | 0.008 | - | 0.35 W | Grommet (lead wire length: 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC5V | M | M5 | 0.008 | - | 0.35 W | Grommet / Lead wire length: 600 mm | Non-locking, push type | Without indicator light / surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC5V | M | M5 | 0.008 | - | 0.35 W | Grommet / Lead wire length: 600 mm | Non-locking, push type | With indicator light / surge voltage suppressor (non-polarized) | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC5V | M | M5 | 0.008 | - | 0.35 W | L plug connector with lead wire (length 300 mm) | Non-locking, push type | Without indicator light / surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC5V | M | M5 | 0.008 | - | 0.35 W | L plug connector, without connector | Non-locking, push type | Without indicator light / surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC5V | M | M5 | 0.008 | - | 0.35 W | L plug connector, without connector | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC5V | M | M5 | 0.008 | - | 0.35 W | L plug connector with lead wire (length 300 mm) | Non-locking, push type | With surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC5V | M | M5 | 0.008 | - | 0.35 W | L plug connector with lead wire (length 300 mm) | Non-locking, push type | With indicator light / surge voltage suppressor (non-polarized) | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC5V | M | M5 | 0.008 | - | 0.35 W | L plug connector with lead wire (length 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC5V | M | M5 | 0.008 | - | 0.35 W | L plug connector with lead wire (length 300 mm) | Locking type, screwdriver operated | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC5V | M | M5 | 0.008 | - | 0.35 W | M plug connector with lead wire (length: 300 mm) | Non-locking, push type | Without indicator light / surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC5V | M | M5 | 0.008 | - | 0.35 W | M plug connector with lead wire (length: 300 mm) | Non-locking, push type | With surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC5V | M | M5 | 0.008 | - | 0.35 W | M plug connector with lead wire (length: 300 mm) | Locking type, screwdriver operated | With surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC5V | M | M5 | 0.008 | - | 0.35 W | M plug connector with lead wire (length: 300 mm) | Non-locking, push type | With indicator light / surge voltage suppressor (non-polarized) | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC5V | M | M5 | 0.008 | - | 0.35 W | M plug connector with lead wire (length: 300 mm) | Locking type, screwdriver operated | With indicator light / surge voltage suppressor (non-polarized) | - | - | ||
990,000 VND | 1 Piece(s) | 32 Day(s) | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC5V | M | M5 | 0.008 | - | 0.35 W | M plug connector with lead wire (length: 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC6V | M | M5 | 0.008 | - | 0.35 W | Grommet (lead wire length: 300 mm) | Non-locking, push type | Without indicator light / surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC6V | M | M5 | 0.008 | - | 0.35 W | Grommet (lead wire length: 300 mm) | Locking type, screwdriver operated | Without indicator light / surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC6V | M | M5 | 0.008 | - | 0.35 W | Grommet (lead wire length: 300 mm) | Non-locking, push type | With surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC6V | M | M5 | 0.008 | - | 0.35 W | Grommet (lead wire length: 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC6V | M | M5 | 0.008 | - | 0.35 W | Grommet / Lead wire length: 600 mm | Non-locking, push type | Without indicator light / surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC6V | M | M5 | 0.008 | - | 0.35 W | Grommet / Lead wire length: 600 mm | Non-locking, push type | With indicator light / surge voltage suppressor (non-polarized) | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC6V | M | M5 | 0.008 | - | 0.35 W | L plug connector with lead wire (length 300 mm) | Non-locking, push type | With surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC6V | M | M5 | 0.008 | - | 0.35 W | L plug connector with lead wire (length 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC6V | M | M5 | 0.008 | - | 0.35 W | M plug connector with lead wire (length: 300 mm) | Non-locking, push type | Without indicator light / surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC6V | M | M5 | 0.008 | - | 0.35 W | M plug connector with lead wire (length: 300 mm) | Non-locking, push type | With indicator light / surge voltage suppressor (non-polarized) | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC6V | M | M5 | 0.008 | - | 0.35 W | M plug connector with lead wire (length: 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
747,333 VND | 1 Piece(s) | 32 Day(s) | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC24V | M | M5 | 0.016 | - | - | L plug connector (with lead wire), lead wire length 300 mm | Locking type, screwdriver operated | Without indicator light / surge voltage suppressor | Standard | Large flow capacity type | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC24V | M | M5 | 0.008 | - | 0.1 W (with energy-saving circuit) | Grommet (lead wire length: 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC24V | M | M5 | 0.008 | - | 0.1 W (with energy-saving circuit) | Grommet (lead wire length: 300 mm) | Locking type, screwdriver operated | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC24V | M | M5 | 0.008 | - | 0.1 W (with energy-saving circuit) | Grommet / Lead wire length: 600 mm | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC24V | M | M5 | 0.008 | - | 0.1 W (with energy-saving circuit) | Grommet / Lead wire length: 600 mm | Locking type, screwdriver operated | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC24V | M | M5 | 0.008 | - | 0.1 W (with energy-saving circuit) | L plug connector without lead wire | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC24V | M | M5 | 0.008 | - | 0.1 W (with energy-saving circuit) | L plug connector, without connector | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC24V | M | M5 | 0.008 | - | 0.1 W (with energy-saving circuit) | L plug connector, without connector | Locking type, screwdriver operated | With indicator light and surge voltage suppressor | - | - | ||
1,069,000 VND | 1 Piece(s) | 32 Day(s) | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC24V | M | M5 | 0.008 | - | 0.1 W (with energy-saving circuit) | L plug connector with lead wire (length 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
1,069,000 VND | 1 Piece(s) | 32 Day(s) | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC24V | M | M5 | 0.008 | - | 0.1 W (with energy-saving circuit) | L plug connector with lead wire (length 300 mm) | Locking type, screwdriver operated | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC24V | M | M5 | 0.008 | - | 0.1 W (with energy-saving circuit) | M plug connector without lead wire | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC24V | M | M5 | 0.008 | - | 0.1 W (with energy-saving circuit) | M plug connector without lead wire | Locking type, screwdriver operated | With indicator light and surge voltage suppressor | - | - | ||
1,049,000 VND | 1 Piece(s) | 32 Day(s) | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC24V | M | M5 | 0.008 | - | 0.1 W (with energy-saving circuit) | M plug connector, without connector | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
1,049,000 VND | 1 Piece(s) | 32 Day(s) | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC24V | M | M5 | 0.008 | - | 0.1 W (with energy-saving circuit) | M plug connector, without connector | Locking type, screwdriver operated | With indicator light and surge voltage suppressor | - | - | ||
1,069,000 VND | 1 Piece(s) | 32 Day(s) | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC24V | M | M5 | 0.008 | - | 0.1 W (with energy-saving circuit) | M plug connector with lead wire (length: 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC24V | M | M5 | 0.008 | - | 0.1 W (with energy-saving circuit) | M plug connector with lead wire (length: 300 mm) | Locking type, screwdriver operated | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC12V | M | M5 | 0.008 | - | 0.1 W (with energy-saving circuit) | Grommet (lead wire length: 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC12V | M | M5 | 0.008 | - | 0.1 W (with energy-saving circuit) | Grommet / Lead wire length: 600 mm | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC12V | M | M5 | 0.008 | - | 0.1 W (with energy-saving circuit) | Grommet / Lead wire length: 600 mm | Locking type, screwdriver operated | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC12V | M | M5 | 0.008 | - | 0.1 W (with energy-saving circuit) | L plug connector without lead wire | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC12V | M | M5 | 0.008 | - | 0.1 W (with energy-saving circuit) | L plug connector, without connector | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC12V | M | M5 | 0.008 | - | 0.1 W (with energy-saving circuit) | L plug connector with lead wire (length 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC12V | M | M5 | 0.008 | - | 0.1 W (with energy-saving circuit) | L plug connector with lead wire (length 300 mm) | Locking type, screwdriver operated | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC12V | M | M5 | 0.008 | - | 0.1 W (with energy-saving circuit) | M plug connector without lead wire | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC12V | M | M5 | 0.008 | - | 0.1 W (with energy-saving circuit) | M plug connector, without connector | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC12V | M | M5 | 0.008 | - | 0.1 W (with energy-saving circuit) | M plug connector with lead wire (length: 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Closed | DC12V | M | M5 | 0.008 | - | 0.1 W (with energy-saving circuit) | M plug connector with lead wire (length: 300 mm) | Locking type, screwdriver operated | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | AC100V | M | M5 | 0.008 | - | 0.35 W | Grommet (lead wire length: 300 mm) | Non-locking, push type | Without indicator light / surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | AC100V | M | M5 | 0.008 | - | 0.35 W | Grommet (lead wire length: 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | AC100V | M | M5 | 0.008 | - | 0.35 W | Grommet / Lead wire length: 600 mm | Locking type, screwdriver operated | Without indicator light / surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | AC100V | M | M5 | 0.008 | - | 0.35 W | L plug connector with lead wire (length 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | AC100V | M | M5 | 0.008 | - | 0.35 W | L plug connector with lead wire (length 300 mm) | Locking type, screwdriver operated | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | AC100V | M | M5 | 0.008 | - | 0.35 W | M plug connector with lead wire (length: 300 mm) | Non-locking, push type | Without indicator light / surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | AC100V | M | M5 | 0.008 | - | 0.35 W | M plug connector, without connector | Non-locking, push type | Without indicator light / surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | AC100V | M | M5 | 0.008 | - | 0.35 W | M plug connector with lead wire (length: 300 mm) | Locking type, screwdriver operated | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | AC200V | M | M5 | 0.008 | - | 0.35 W | M plug connector with lead wire (length: 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | AC200V | M | M5 | 0.008 | - | 0.35 W | M plug connector with lead wire (length: 300 mm) | Locking type, screwdriver operated | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | 10 | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | AC110V | M | M5 | 0.008 | - | 0.35 W | L plug connector (with lead wire), lead wire length 300 mm | Non-locking, push type | With indicator light and surge voltage suppressor | Standard | Standard Type | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | DC24V | M | M5 | 0.008 | - | 0.35 W | Grommet (lead wire length: 300 mm) | Non-locking, push type | Without indicator light / surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | DC24V | M | M5 | 0.008 | - | 0.35 W | Grommet (lead wire length: 300 mm) | Locking type, screwdriver operated | Without indicator light / surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | DC24V | M | M5 | 0.008 | - | 0.35 W | Grommet (lead wire length: 300 mm) | Non-locking, push type | With surge voltage suppressor (non-polarized) | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | DC24V | M | M5 | 0.008 | - | 0.35 W | Grommet (lead wire length: 300 mm) | Non-locking, push type | With surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | DC24V | M | M5 | 0.008 | - | 0.35 W | Grommet (lead wire length: 300 mm) | Locking type, screwdriver operated | With surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | DC24V | M | M5 | 0.008 | - | 0.35 W | Grommet (lead wire length: 300 mm) | Non-locking, push type | With indicator light / surge voltage suppressor (non-polarized) | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | DC24V | M | M5 | 0.008 | - | 0.35 W | Grommet (lead wire length: 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | DC24V | M | M5 | 0.008 | - | 0.35 W | Grommet / Lead wire length: 600 mm | Non-locking, push type | Without indicator light / surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | DC24V | M | M5 | 0.008 | - | 0.35 W | Grommet / Lead wire length: 600 mm | Locking type, screwdriver operated | Without indicator light / surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | DC24V | M | M5 | 0.008 | - | 0.35 W | Grommet / Lead wire length: 600 mm | Non-locking, push type | With surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | DC24V | M | M5 | 0.008 | - | 0.35 W | Grommet / Lead wire length: 600 mm | Non-locking, push type | With indicator light / surge voltage suppressor (non-polarized) | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | DC24V | M | M5 | 0.008 | - | 0.35 W | Grommet / Lead wire length: 600 mm | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | DC24V | M | M5 | 0.008 | - | 0.35 W | L plug connector with lead wire (length 300 mm) | Non-locking, push type | Without indicator light / surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | DC24V | M | M5 | 0.008 | - | 0.35 W | L plug connector with lead wire (length 300 mm) | Locking type, screwdriver operated | Without indicator light / surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | DC24V | M | M5 | 0.008 | - | 0.35 W | L plug connector, without connector | Non-locking, push type | Without indicator light / surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | DC24V | M | M5 | 0.008 | - | 0.35 W | L plug connector, without connector | Non-locking, push type | With indicator light / surge voltage suppressor (non-polarized) | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | DC24V | M | M5 | 0.008 | - | 0.35 W | L plug connector, without connector | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | DC24V | M | M5 | 0.008 | - | 0.35 W | L plug connector with lead wire (length 300 mm) | Non-locking, push type | With surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | DC24V | M | M5 | 0.008 | - | 0.35 W | L plug connector with lead wire (length 300 mm) | Non-locking, push type | With indicator light / surge voltage suppressor (non-polarized) | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | DC24V | M | M5 | 0.008 | - | 0.35 W | L plug connector with lead wire (length 300 mm) | Locking type, screwdriver operated | With indicator light / surge voltage suppressor (non-polarized) | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | DC24V | M | M5 | 0.008 | - | 0.35 W | L plug connector with lead wire (length 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | DC24V | M | M5 | 0.008 | - | 0.35 W | M plug connector with lead wire (length: 300 mm) | Non-locking, push type | Without indicator light / surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | DC24V | M | M5 | 0.008 | - | 0.35 W | M plug connector with lead wire (length: 300 mm) | Locking type, screwdriver operated | Without indicator light / surge voltage suppressor | - | - | ||
- | 1 Piece(s) | Quote | - | Single Use | Direct | Standard / Lubrication Free | 2-Position Normally Open | DC24V | M | M5 | 0.008 | - | 0.35 W | M plug connector without lead wire | Non-locking, push type | With indicator light / surge voltage suppressor (non-polarized) | - | - |
Loading...Tải…
Type | Solenoid Valves | Number of Ports | 3-Port Valve | Number of Solenoids | Single |
---|---|---|---|---|---|
Status at Power Off | Self-Recovery (Spring Return) | Plumbing | Sub-Base Plumbing | Driving Type | Linear Motion Spool |
Seal Type | Soft Seal | Pressure Rating(MPa) | 0 to 0.7 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy