(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Caution
thận trọng
SMC Gap Checker.
[Features]
· At-a-glance checking of whether the workpiece is placed correctly or not.
· Allows you to intuitively know how much of a gap there is between the workpiece and the detecting surface.
· Easy setting: Allows you to change the settings and see the values change on the display.
· Energy-saving type: Air consumption reduced by 60%.
· Improved drainage resistance: by 10 times or more.
[Applications]
· Checking the reference plane for the press fitting of shafts.
· Confirmation of close contact with the reference plane for machining.
· Confirmation of close contact with the workpiece for machining.
Model | ISA3-F | ISA3-G | ISA3-H | |||
---|---|---|---|---|---|---|
Applicable fluid | Dry air (filtered through a 5‑μm filter) | |||||
OUT 1 OUT2*5 | Rated distance range | 0.01 to 0.03 mm | 0.02 to 0.15 mm | 0.05 to 0.30 mm | ||
Displayable/settable range (distance reference)*1 | 0 to 60*2 | 10 to 300*2 | 30 to 500*2 | |||
Minimum display resolution (distance reference)*1 | 1 | |||||
Rated pressure range | 100 to 200 kPa | |||||
Displayable range (pressure value)*3 | -20 to 220 kPa | |||||
Repeatability | 0.005 mm or less | 0.010 mm or less | 0.020 mm or less | |||
Temperature characteristics (reference: 25°C) | 0.010 mm or less | 0.015 mm or less | 0.030 mm or less | |||
Hysteresis | 0 to variable (default: 3) | 0 to variable (at factory setting: 20) | ||||
OUT2 *6 | Rated pressure range | 0 to 200 kPa | ||||
Set pressure range | -20 to 220 kPa | |||||
Minimum display/setting unit | 1 kPa | |||||
Repeatability | ±0.5% F.S. ±1 digit | |||||
Temperature characteristics (reference: 25°C) | ±2% F.S. | |||||
Hysteresis | Hysteresis mode | 0 to variable*7 | ||||
Window comparator mode | ||||||
Withstand pressure | 600 kPa | |||||
Detection nozzle | ø1.5 (diameter 1.5 mm)*4 | |||||
Consumption flow rate | 5 L/min or less | 12 L/min or less | 22 L/min or less | |||
Power supply voltage | 24 V DC ±10%, Ripple (p-p10% or less) (with power supply polarity protection) | |||||
Current consumption | 25 mA or less | |||||
Switch output | - | 1 output (NPN or PNP), 2 outputs (NPN or PNP) | ||||
Maximum load current | 10 mA | |||||
Maximum applied voltage | 26.4 V | |||||
Residual voltage | 1 V or less (at 10 mA) | |||||
Short-circuit protection | Yes | |||||
Display | 2-screen display LCD Main screen: 3-digit, 7-segment, 2-color display (orange/green) Sub screen: 6-digit, 7-segment, 1-color display (white) | |||||
Environment | Enclosure | IP67 equivalent | ||||
Operating temperature range | Operating: 0 to 50°C, Stored: -20 to 70°C (no condensation or freezing) | |||||
Operating humidity range | Operating/stored: 35 to 85% RH (no condensation) | |||||
Withstand Voltage | 1,000 V AC or more (at 50/60 Hz) for 1 minute, between terminals and housing | |||||
Insulation Resistance | 2 MΩ or more (500 V DC measured via megohmmeter) between terminals and housing | |||||
Piping specifications | For C type | Supply port | Rc 1/8 | |||
Detection port | ø4 (diameter 4 mm) single-action fitting | ø6 (diameter 6 mm) single-action fitting | ||||
For F type | Supply port | G1/8 (ISO1179-1 compliant) | ||||
Detection port | G1/8 (ISO1179-1 compliant) | |||||
Cable | Lead wire with connector | M12 lead wire with 4-pin connector, 4 cores, ø4 (diameter 4 mm), 5 m Conductor O.D.: 0.72 mm, Insulator O.D.: 1.14 mm | ||||
Centralized lead wire | M12 lead wire with 4 pin connector, 4 cores, ø4 (diameter 4 mm), Insulator O.D.: 1.14 mm Centralized lead wire part: 2 to 3 stations: 5 cores, ø4 (diameter 4 mm), 5 m, 4 to 6 stations: 8 cores, ø6 (diameter 6 mm), 5 m Conductor O.D.: 0.50 mm, Insulator O.D.: 1.00 mm (2 to 6 stations common) | |||||
Weight | 113 g (cable not included, single-action fitting) | |||||
Standards | CE |
(Unit: mm)
Dimensions: ISA3-□□ (bracket mounted)
(Unit: mm)
Stations | 1 | 2 | 3 | 4 | 5 | 6 |
---|---|---|---|---|---|---|
L1 | 38 | 76 | 114 | 152 | 190 | 228 |
Piping specifications | C (ø4 [diameter 4 mm] single-action fitting) | C (ø6 [diameter 6 mm] single-action fitting) | F (G thread) |
---|---|---|---|
H | 13 | 13.6 | 19 |
ISA3-□□ (bracket mounted) pin numbers
(Unit: mm)
Dimensions: ISA3-□□ (DIN rail mounted)
(Unit: mm)
Stations | 1 | 2 | 3 | 4 | 5 | 6 |
---|---|---|---|---|---|---|
L1 | 38 | 76 | 114 | 152 | 190 | 228 |
L2 | 62.5 | 125 | 162.5 | 200 | 237.5 | 275 |
L3 | 73 | 135.5 | 173 | 210.5 | 248 | 285.5 |
Piping specifications | C (ø4 [diameter 4 mm] single-action fitting) | C (ø6 [diameter 6 mm] single-action fitting) | F (G thread) |
---|---|---|---|
H | 13 | 13.6 | 19 |
ISA3-□□ (DIN rail mounted) pin numbers
The distance for the product to turn ON varies depending on the supply pressure.
The charts below show the variation of the distance for the product to turn ON, for 3 types of gap, by changing the supply pressure (±50 kPa) when the product is set to turn ON at a supply pressure of 150 kPa.
Detection nozzle: ø1.5 (diameter 1.5 mm), Piping: F type ø4 (diameter 4 mm) × ø2.5 (diameter 2.5 mm) tube / G, H type ø6 (diameter 6 mm) × ø4 (diameter 4 mm) tube, Reference pressure: 150 kPa
Supply pressure dependence characteristics of ISA3-F
Supply pressure dependence characteristics of ISA3-G
Supply pressure dependence characteristics of ISA3-H
*Refer to the manufacturer's catalog for other models, specifications, etc.
Part Number |
---|
ISA3-FFN-M2B |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | RoHS | Control unit | Number of stations | Voltage (V) | Detection distance (mm) | Piping specifications | Output specifications | Unit specification for pressure values | Regulator | Cable |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | 10 | Without control unit | 2 stations | 24 DC | 0.01 to 0.03 | Supply side (G1/8), detection side (G1/8) | NPN 1 output | SI unit fixed | - | Straight cable |
Loading...Tải…
Option | With Bracket |
---|
Please check the type/dimensions/specifications of the part ISA3-FFN-M2B in the Digital Gap Checker, 3-Color Display, With Control Unit, ISA3 Series series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần ISA3-FFN-M2B trong chuỗi Digital Gap Checker, 3-Color Display, With Control Unit, ISA3 Series.
Part Number |
---|
ISA3-FCA-M1B-L2 |
ISA3-FCA-M1LB |
ISA3-FCB-1B-L1 |
ISA3-FFP-1B-L2 |
ISA3-FFP-6TB-L2 |
ISA3-FFP-M1B |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to ShipSố ngày giao hàng | RoHS | Control unit | Number of stations | Voltage (V) | Detection distance (mm) | Piping specifications | Output specifications | Unit specification for pressure values | Regulator | Cable |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | 10 | With control unit (supply port: left side) | 1 station | 24 DC | 0.01 to 0.03 | Supply side (Rc1/8), detection side (ø4 single-action) | NPN 2 output | SI unit fixed | With regulator / Square type pressure gauge / 0.4 MPa / MPa Single notation | Straight cable | ||
- | 1 Piece(s) | Quote | 10 | Without control unit | 1 station | 24 DC | 0.01 to 0.03 | Supply side (Rc1/8), detection side (ø4 single-action) | NPN 2 output | SI unit fixed | - | Right-angle cable | ||
- | 1 Piece(s) | Quote | 10 | With control unit (supply port: left side) | 1 station | 24 DC | 0.01 to 0.03 | Supply side (Rc1/8), detection side (ø4 single-action) | PNP 2 output | With unit switching function | With regulator / Round type pressure gauge / 0.4 MPa / MPa single notation | Straight cable | ||
- | 1 Piece(s) | Quote | 10 | With control unit (supply port: left side) | 1 station | 24 DC | 0.01 to 0.03 | Supply side (G1/8), detection side (G1/8) | PNP 1 output | With unit switching function | With regulator / Square type pressure gauge / 0.4 MPa / MPa Single notation | Straight cable | ||
- | 1 Piece(s) | Quote | 10 | With control unit (supply port: left side) | 6 stations | 24 DC | 0.01 to 0.03 | Supply side (G1/8), detection side (G1/8) | PNP 1 output | With unit switching function | With regulator / Square type pressure gauge / 0.4 MPa / MPa Single notation | Centralized lead wire (with bracket) | ||
- | 1 Piece(s) | Quote | 10 | Without control unit | 1 station | 24 DC | 0.01 to 0.03 | Supply side (G1/8), detection side (G1/8) | PNP 1 output | SI unit fixed | - | Straight cable |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy