(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Caution
thận trọng
Compatible with Japan's Food Sanitation Law.
[Features]
・ Flexibility: About 20% improvement
・ Operating temperature is MAX.260°C
[Applications]
・ Ideal for use when flexibility is required
Size | Metric Size | |||||
---|---|---|---|---|---|---|
Nominal | TD0425 | TD0604 | TD0806 | TD1075 | TD1209 | |
Outer diameter (mm) | 4 | 6 | 8 | 10 | 12 | |
Inner diameter (mm) | 2.5 | 4 | 6 | 7.5 | 9 | |
Roll | 10 m | ● | ● | ● | ● | ● |
20 m | ● | ● | ● | ● | ● | |
Color | Translucent (material color) | |||||
Applicable Fluids | See the catalog for applicable fluids. | |||||
FluidNote 1) | Air, waterNote 1), inert gas | |||||
Applicable fittingsNote 1) | Insert fittings KF Series Stainless steel 316 insert fittings KFG Series Miniature fittings M, MS Series (Hose-nipple type) Fluoropolymer fittings LQ Series | |||||
Maximum operating pressure (MPa) | 20°C | 1.6 | 1.4 | 0.9 | 0.9 | 0.9 |
100°C | 0.9 | 0.7 | 0.5 | 0.5 | 0.5 | |
200°C | 0.45 | 0.35 | 0.25 | 0.25 | 0.25 | |
260°C | 0.23 | 0.2 | 0.15 | 0.15 | 0.15 | |
Minimum bending radius mmNote 3) | Recommended radius | 15 | 25 | 45 | 55 | 75 |
Tube close bend radius | 8 | 16 | 31 | 35 | 41 | |
Maximum operating temperature (fixed usage) | 260°C | |||||
Material | Modified PTFE (Polytetrafluoroethylene resin) |
Note 1) When using a liquid fluid, the surge pressure must be under the maximum operating pressure. If the surge pressure exceeds the maximum operating pressure, it will result in damage to the fittings and tubing. Furthermore, abnormal temperature rise caused by adiabatic compression may result in the tubing bursting.
Note 2) Do not use this product in a manner in which the tubing is not fixed. Observe the lesser value of the maximum operating pressure between the tubing and fittings. A material change over a long duration or due to high temperature may cause leakage. Perform periodic maintenance and replace with a new product immediately when abnormalities are detected.
Note 3) The minimum bending radius is the representative value measured as shown in the figure on the left.
How to measure the minimum bending radius
Bend the tubing into a U shape at a temperature of 20°C. Fix one end and close the loop gradually. Measure 2R when the deformed ratio of the tubing diameter at bending reaches 5%.
Maximum operating pressure
Size | Inch Size | |||||
---|---|---|---|---|---|---|
Nominal | TID01 | TID05 | TID07 | TID11 | TID13 | |
Outer diameter | inch | 1/8 " | 3/16 " | 1/4 " | 3/8 " | 1/2 " |
mm | 3.18 | 4.75 | 6.35 | 9.53 | 12.7 | |
Inner diameter | inch | 0.086 " | 0.124 " (1/8 ") | 0.156 " (5/32 ") | 0.25 " (1/4 ") | 0.374 " (3/8 ") |
mm | 2.18 | 3.15 | 3.95 | 6.33 | 9.5 | |
Roll | 8 m (25 ft) | ● | ● | ● | ● | ● |
16 m (50 ft) | ● | ● | ● | ● | ● | |
Color | Translucent (material color) | |||||
Applicable Fluids | See the catalog for applicable fluids. | |||||
FluidNote 1) | Air, waterNote 1), inert gas | |||||
Applicable fittingsNote 2) | Fluoropolymer Fittings LQ Series | |||||
Maximum operating pressure (MPa) | 20°C | 1.4 | 1.4 | 1.6 | 1.4 | 0.9 |
100°C | 0.7 | 0.7 | 0.9 | 0.7 | 0.5 | |
200°C | 0.35 | 0.35 | 0.45 | 0.35 | 0.25 | |
260°C | 0.2 | 0.2 | 0.23 | 0.2 | 0.15 | |
Minimum bending radius mmNote 3) | Recommended radius | 15 | 20 | 25 | 40 | 75 |
Tube close bend radius | 9 | 10 | 15 | 23 | 42 | |
Maximum operating temperature (fixed usage) | 260°C | |||||
Material | Modified PTFE (Polytetrafluoroethylene resin) |
Note 1) When using a liquid fluid, the surge pressure must be under the maximum operating pressure. If the surge pressure exceeds the maximum operating pressure, it will result in damage to the fittings and tubing. Furthermore, abnormal temperature rise caused by adiabatic compression may result in the tubing bursting.
Note 2) Do not use this product in a manner in which the tubing is not fixed. Observe the lesser value of the maximum operating pressure between the tubing and fittings. A material change over a long duration or due to high temperature may cause leakage. Perform periodic maintenance and replace with a new product immediately when abnormalities are detected.
Note 3) The minimum bending radius is the representative value measured as shown in the figure on the left.
How to measure the minimum bending radius
Bend the tubing into a U shape at a temperature of 20°C. Fix one end and close the loop gradually. Measure 2R when the deformed ratio of the tubing diameter at bending reaches 5%.
Maximum operating pressure
Part Number |
---|
TD1209-10 |
TD1209-20 |
TID13-8 |
TID13-16 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Outer Dia. D (Ø) | O.D. [Distinction] | Inner Dia. d (Ø) | I.D. [Distinction] | Minimum Bending Radius (mm) | Bundle winding length (m) | Applicable Tube Size | Maximum operating pressure (MPa) |
---|---|---|---|---|---|---|---|---|---|---|---|---|
8,230,400 VND | 1 Piece(s) | 32 Day(s) | 12 | ~15 | 9 | ~9 | - | 10 | Metric Size | 0.9 | ||
16,460,000 VND | 1 Piece(s) | 32 Day(s) | 12 | ~15 | 9 | ~9 | - | 20 | Metric Size | 0.9 | ||
7,579,200 VND | 1 Piece(s) | 32 Day(s) | - | ~15 | - | ~10 | - | 8 | Inch Size | 0.9 | ||
15,157,600 VND | 1 Piece(s) | 32 Day(s) | - | ~15 | - | ~10 | - | 16 | Inch Size | 0.9 |
Loading...Tải…
Type | Straight | Cutting Service Usage | No | Material | Fluororesin |
---|---|---|---|---|---|
Applicable Fluid | Water / Air | Operating Environment | Standard / Chemical Resistance | Color | Translucent (Material Color) |
Material, Fluororesin | Denatured PTFE (Ethylene Resin Tetrafluoride) | Operating temperature(°C) | up to 260 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy