(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.

  • Viewed
    Products
    Sản phẩm
    đã xem
    최근 본
    상품
    查看产品 查看產品
  • My
    Components
    Linh kiện
    của tôi
    나의 부품 我的部件 我的部件
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • [Thông báo] Cập nhật địa chỉ kho tập kết hàng hóa tại khu vực miền Nam của MISUMI Việt Nam. Xem chi tiết.
    [Announcement] Update on warehouse address in the Southern region of MISUIMI Vietnam. See more. 
  • [Cảnh Báo] Thủ Đoạn Lừa Đảo Từ Nhân Viên Giao Hàng – Yêu Cầu Trả Phí Ship. Xem chi tiết.
    [Warning] Fraud Calling from Shipper - Asking to Pay Shipping Fee. See more.

Flame Retardant (Equivalent To UL-94 Standard V-0) FR Double Layer Polyurethane Tubing TRBU Series (TRBU0805B-100)

Flame Retardant (Equivalent To UL-94 Standard V-0) FR Double Layer Polyurethane Tubing TRBU Series (TRBU0805B-100)

Click this image to zoom it.Nhấp vào hình ảnh này để phóng to.

Move the mouse over or click the image to zoom

You can add up to 6 items per a category to the compare list.

Part Number :
  • Order Qty :
  • Price :
    ---
  • Total Price :
    ---
  • Days to ship :
    ---

Select part number to Order Now/ Add to Cart

  • CAD Data unavailable

(i)

Caution

thận trọng

  • For specifications and details, please refer to the catalog.
  • Product pictures are representations.

Product Description

Double-layer polyurethane tubing.
[Features]
· Maximum operating pressure 0.8 MPa or less (at 20°C).
· For use in areas where spatter occurs. Flame retardant (equivalent to UL-94 standard V-0).
· Superior resiliency even when compared to nylon tubing.

Specifications of FR Double Layer Polyurethane Tubing TRBU Series

Cross-section of FR Double Layer Tubing

Cross-section of FR Double Layer Tubing

Maximum operating pressure

Maximum operating pressure

Series List

NominalTRBU0604TRBU0805TRBU1065TRBU1208
Inner tubing outer diameter mm681012
Inner tubing inner diameter mm456.58
Outer layer thickness mm1111
Minimum bending radius mm15202735

Specifications

FluidAir, water
Maximum operating pressure (MPa)20°C0.8
40°C0.65
60°C0.5
Applicable fittingsFR One-touch Fittings KR-W2 Series
Ambient and fluid temperature-20 to +60℃, Water: 0 to 40°C (No freezing)
MaterialInner tubePolyurethane
Outer layerPolyolefin resin (equivalent to UL-94 standard V-0)

Note: All inner tubes are black in color.

How To Install On One-Touch Fittings

Procedure

Procedure

The length and pitch for mounting on one-touch fittings are indicated on the outer layer of the TRBU tube. Cut the tube in accordance with the indications (step 1), then peel off only the outer layer (step 2) and mount on the one-touch fitting.

Caution

  • 1. Applicable for general industrial water. Please contact SMC if using other kinds of fluid. Also, the surge pressure must not exceed the maximum operating pressure. If the surge pressure exceeds the maximum operating pressure, it will result in damage to fittings and tubes.
  • 2. Abnormal temperature rise caused by adiabatic compression may result in the tube bursting.
  • 3. The value of the minimum bending radius is measured at the temperature of 20°C as shown in the figure below.
Minimum bending radius

Minimum bending radius

Bend the tube into a U shape at a temperature of 20°C. Fix one end and close the loop gradually. Measure 2R when the tube breaks or is crushed.

Part Number
TRBU0805B-100
Part NumberPriceMinimum Order Qty.Volume DiscountDays to ShipSố ngày giao hàngMinimum Bending Radius
(mm)
Bundle winding length
(m)
Reel winding length
(m)
Inner Tube O.D. D
(mm)
Inner Tube I.D. d
(mm)
Outer Layer Color

13,125,600 VND

1 Piece(s) 32 Day(s) 20-10085Black

Loading...Tải…

  1. 1
 

Basic InformationThông tin cơ bản

Type Straight Cutting Service Usage No Applicable Fluid Water / Air
Operating Environment Standard Material Inner Tube: Polyurethane / Outer Layer: Polyolefin-Type Resin (UL-94 Standard V-0 Equivalent) Maximum operating pressure(MPa) 0.8 (at 20°C)
Operating temperature(°C) -20 to +60, With Water: 0 to +40 (Do Not Freeze)

Please check the type/dimensions/specifications of the part TRBU0805B-100 in the Flame Retardant (Equivalent To UL-94 Standard V-0) FR Double Layer Polyurethane Tubing TRBU Series series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần TRBU0805B-100 trong chuỗi Flame Retardant (Equivalent To UL-94 Standard V-0) FR Double Layer Polyurethane Tubing TRBU Series.

Products like this...

Part Number
TRBU0604BU-20
TRBU0604G-100
TRBU0604G-20
TRBU0805B-20
TRBU0805BU-100
TRBU0805BU-20
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipSố ngày giao hàngMinimum Bending Radius
(mm)
Bundle winding length
(m)
Reel winding length
(m)
Inner Tube O.D. D
(mm)
Inner Tube I.D. d
(mm)
Outer Layer Color

1,503,200 VND

1 Piece(s) Same day 1520-64Blue

7,516,000 VND

1 Piece(s) 32 Day(s) 15-10064Green

1,503,200 VND

1 Piece(s) 32 Day(s) 1520-64Green

2,625,600 VND

1 Piece(s) 35 Day(s) 2020-85Black

13,125,600 VND

1 Piece(s) 4 Day(s) 20-10085Blue

2,625,600 VND

1 Piece(s) Same day 2020-85Blue