(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Caution
thận trọng
A pressure switch made by SMC.
[Features]
· Low flow (1 L/min) setting is possible
· Easy to set
It can be set with a screwdriver from the outside without removing the cover
· With light
[Applications]
· Used for detection and confirmation of flow as a general-purpose water cutoff, water reduction relay in cooling water fixtures in general industrial machinery.
External appearance of IFW5 Series
Fluid | Water / Non corrosive liquid* | |
---|---|---|
Operating Pressure | 0.1 to 0.6 MPa | |
Water resistance | 1.2 MPa | |
Operating temperature range | -5 to 60°C (no freezing) | |
Action | Diaphragm Regulator | |
Insulation Resistance | 100 MΩ or more (500 DC by insulation resistance tester) | |
Withstand Voltage | 1,500 V AC for 1 minute | |
Contact | Without terminal box: 1ab | |
With terminal box: 1a and 1b | ||
Connection port size | 3/8, 1/2, 3/4 | |
Liquid-contacting parts material | Body | CAC408 |
Rod | C3604B | |
Diaphragm | *)NBR |
* Please contact the manufacturer support center for further details of use.
*) Select "-X404" for ozone environment.
Model | Set flow rate range L/min | Maximum flow rate L/min | *) Hysteresis L/min |
---|---|---|---|
IFW510 | 1 to 10 | 20 | 1 or less |
IFW520 | 10 to 20 | 25 | 1.5 or less |
IFW550 | 20 to 50 | 60 | 3 or less |
*) Hysteresis is the flow rate required to move the micro switch from the operating position (ON signal) to the return position (OFF signal). (Typical value)
Voltage | Non-inductive load (A) | Inductive load (A) | ||||||
---|---|---|---|---|---|---|---|---|
Load resistance | Lamp load | Inductive load | Electric motor load | |||||
N.C. | N.O. | N.C. | N.O. | N.C. | N.O. | N.C. | N.O. | |
AC125V | 5 | 5 | 1.5 | 0.7 | 4 | 4 | 2.5 | 1.3 |
AC250V | 5 | 5 | 1 | 0.5 | 4 | 4 | 1.5 | 0.8 |
DC8V | 7 | 5 | 3 | 3 | 5 | 4 | 3 | 3 |
DC14V | 5 | 5 | 3 | 3 | 4 | 4 | 3 | 3 |
DC30V | 5 | 5 | 3 | 3 | 4 | 4 | 3 | 3 |
DC125V | 0.4 | 0.4 | 0.1 | 0.1 | 0.4 | 0.4 | 0.1 | 0.1 |
DC250V | 0.3 | 0.3 | 0.05 | 0.05 | 0.3 | 0.3 | 0.05 | 0.05 |
IFW5 Series structure and operating principle diagram
Operating Principle
When water flows, a differential pressure is generated before and after the orifice at the port of body 1. This differential pressure is detected by a pair of upper and lower diaphragms, rod 2 is displaced downward, operating lever 4 is lowered, and the micro switch is turned on.
If the flow rate is increased, the rod will be displaced downwards by 2, and if it is decreased, it will be displaced upwards. In addition, the adjustment gear 5 can be rotated and the gear 3 can be moved vertically to detect signals at any flow rate.
Number | Part Name | Material |
---|---|---|
1 | Body | CAC408 |
2 | Rod | C3604B |
3 | Gear | POM |
Number | Part Name | Material |
---|---|---|
4 | Operating lever | SPCC |
5 | Adjusting gear | POM |
IFW510 flow rate characteristics (Typical value)
IFW520 flow rate characteristics (Typical value)
IFW550 flow rate characteristics (Typical value)
(Units: mm)
Dimensional drawing of IFW5□0-□□-00 to 04 (without terminal box)
Dimensional drawing of IFW5□0-□□-10 to 24 (with terminal box)
Dimensional drawing of IFW5□0-□□-55 to 86 (with 24 V DC lamp and terminal box)
Internal wiring diagram of IFW5□0-□□-00, 10, 20
Symbol | Contact | Lead Wire Color |
---|---|---|
C | COMMON | Black |
A | NORMALLY OPEN | White |
B | NORMALLY CLOSED | Red |
Internal wiring diagram of IFW5□0-□□-01 to 04, 11 to 14, 21 to 24
Symbol | Contact | Lead Wire Color |
---|---|---|
C | COMMON | Black |
A | NORMALLY OPEN | White |
B | NORMALLY CLOSED | Red |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | RoHS | Flow Rate Range (Max. Value) (L/min) | Plumbing Thread Type | Plumbing Thread Nominal | Rating Flow Range (L/min) | Contact configuration | Terminal box | Lamp | CE compliant |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | - | 50~Less than 100 | [G] G | [3/4] 3/4 | 20 to 50 | 1a | With terminal box (For 24 V DC/-COM) | With LED light (24 V DC, green) | Non-Compatible | ||
- | 1 Piece(s) | Quote | 10 | 50~Less than 100 | [NPT] NPT | [3/8] 3/8 | 20 to 50 | 1ab | Without terminal box | Without light | Non-Compatible | ||
- | 1 Piece(s) | Quote | 10 | 50~Less than 100 | [NPT] NPT | [3/8] 3/8 | 20 to 50 | 1ab | Without terminal box | With neon light (110 V AC, red) | Non-Compatible | ||
- | 1 Piece(s) | Quote | 10 | 50~Less than 100 | [NPT] NPT | [3/8] 3/8 | 20 to 50 | 1ab | Without terminal box | With neon lamp (220 V AC red) | Non-Compatible | ||
- | 1 Piece(s) | Quote | 10 | 50~Less than 100 | [NPT] NPT | [3/8] 3/8 | 20 to 50 | 1a | With terminal box | Without light | Non-Compatible | ||
- | 1 Piece(s) | Quote | 10 | 50~Less than 100 | [NPT] NPT | [3/8] 3/8 | 20 to 50 | 1a | With terminal box | With neon light (110 V AC, red) | Non-Compatible | ||
- | 1 Piece(s) | Quote | 10 | 50~Less than 100 | [NPT] NPT | [3/8] 3/8 | 20 to 50 | 1b | With terminal box (For 24 V DC/+COM) | With LED light (24 V DC, red) | Non-Compatible | ||
- | 1 Piece(s) | Quote | 10 | 50~Less than 100 | [NPT] NPT | [1/2] 1/2 | 20 to 50 | 1ab | Without terminal box | Without light | Non-Compatible | ||
- | 1 Piece(s) | Quote | 10 | 50~Less than 100 | [NPT] NPT | [1/2] 1/2 | 20 to 50 | 1a | With terminal box | Without light | Non-Compatible | ||
5,361,000 VND | 1 Piece(s) | 32 Day(s) | - | 50~Less than 100 | [NPT] NPT | [1/2] 1/2 | 20 to 50 | 1b | With terminal box (For 24 V DC/+COM) | With LED light (24 V DC, red) | Non-Compatible | ||
- | 1 Piece(s) | Quote | 10 | 50~Less than 100 | [NPT] NPT | [3/4] 3/4 | 20 to 50 | 1ab | Without terminal box | Without light | Non-Compatible | ||
- | 1 Piece(s) | Quote | 10 | 50~Less than 100 | [NPT] NPT | [3/4] 3/4 | 20 to 50 | 1ab | Without terminal box | Without light | CE-compliant product | ||
- | 1 Piece(s) | Quote | 10 | 50~Less than 100 | [NPT] NPT | [3/4] 3/4 | 20 to 50 | 1ab | Without terminal box | With neon light (110 V AC, red) | Non-Compatible | ||
- | 1 Piece(s) | Quote | 10 | 50~Less than 100 | [NPT] NPT | [3/4] 3/4 | 20 to 50 | 1ab | Without terminal box | With neon lamp (220 V AC, green) | Non-Compatible | ||
4,886,000 VND | 1 Piece(s) | 32 Day(s) | - | 50~Less than 100 | [NPT] NPT | [3/4] 3/4 | 20 to 50 | 1a | With terminal box | Without light | Non-Compatible | ||
- | 1 Piece(s) | Quote | 10 | 50~Less than 100 | [NPT] NPT | [3/4] 3/4 | 20 to 50 | 1a | With terminal box | Without light | CE-compliant product | ||
- | 1 Piece(s) | Quote | 10 | 50~Less than 100 | [NPT] NPT | [3/4] 3/4 | 20 to 50 | 1a | With terminal box | With neon light (110 V AC, red) | Non-Compatible | ||
- | 1 Piece(s) | Quote | 10 | 50~Less than 100 | [NPT] NPT | [3/4] 3/4 | 20 to 50 | 1a | With terminal box | With neon lamp (110 V AC green) | Non-Compatible | ||
- | 1 Piece(s) | Quote | 10 | 50~Less than 100 | [NPT] NPT | [3/4] 3/4 | 20 to 50 | 1a | With terminal box | With neon lamp (110 V AC green) | CE-compliant product | ||
- | 1 Piece(s) | Quote | 10 | 50~Less than 100 | [NPT] NPT | [3/4] 3/4 | 20 to 50 | 1a | With terminal box | With neon lamp (220 V AC red) | Non-Compatible | ||
- | 1 Piece(s) | Quote | 10 | 50~Less than 100 | [NPT] NPT | [3/4] 3/4 | 20 to 50 | 1a | With terminal box | With neon lamp (220 V AC, green) | Non-Compatible | ||
4,886,000 VND | 1 Piece(s) | 32 Day(s) | - | 50~Less than 100 | [NPT] NPT | [3/4] 3/4 | 20 to 50 | 1b | With terminal box | Without light | Non-Compatible | ||
- | 1 Piece(s) | Quote | 10 | 50~Less than 100 | [NPT] NPT | [3/4] 3/4 | 20 to 50 | 1b | With terminal box (For 24 V DC/+COM) | With LED light (24 V DC, red) | Non-Compatible | ||
- | 1 Piece(s) | Quote | 10 | 50~Less than 100 | [NPT] NPT | [3/4] 3/4 | 20 to 50 | 1b | With terminal box (For 24 V DC/+COM) | With LED light (24 V DC, green) | Non-Compatible | ||
- | 1 Piece(s) | Quote | 10 | 50~Less than 100 | [NPT] NPT | [3/4] 3/4 | 20 to 50 | 1a | With terminal box (For 24 V DC/+COM) | With LED light (24 V DC, red) | Non-Compatible | ||
- | 1 Piece(s) | Quote | 10 | 50~Less than 100 | [NPT] NPT | [3/4] 3/4 | 20 to 50 | 1a | With terminal box (For 24 V DC/+COM) | With LED light (24 V DC, green) | Non-Compatible | ||
- | 1 Piece(s) | Quote | 10 | 50~Less than 100 | [NPT] NPT | [3/4] 3/4 | 20 to 50 | 1b | With terminal box (For 24 V DC/-COM) | With LED light (24 V DC, red) | Non-Compatible | ||
- | 1 Piece(s) | Quote | 10 | 50~Less than 100 | [NPT] NPT | [3/4] 3/4 | 20 to 50 | 1b | With terminal box (For 24 V DC/-COM) | With LED light (24 V DC, green) | Non-Compatible | ||
- | 1 Piece(s) | Quote | 10 | 50~Less than 100 | [NPT] NPT | [3/4] 3/4 | 20 to 50 | 1a | With terminal box (For 24 V DC/-COM) | With LED light (24 V DC, red) | Non-Compatible | ||
- | 1 Piece(s) | Quote | 10 | 50~Less than 100 | [NPT] NPT | [3/4] 3/4 | 20 to 50 | 1a | With terminal box (For 24 V DC/-COM) | With LED light (24 V DC, green) | Non-Compatible |
Loading...Tải…
Type | Flow Switch | Fluid Type | Water | Sensor, Monitor Structure | Integrated shape |
---|---|---|---|---|---|
Output Method | Switch | Pipe Port Type | Female Thread | Fluid Characteristics | Noncorrosive |
Number of Output Points | 1 | Applicable Fluid | Water / Non corrosive liquid* | Rated Pressure Range | 0.1 to 0.6 MPa |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy