(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Part Number |
---|
PRWT08-1.5DC |
PRWT08-1.5DO |
PRWT08-2DC |
PRWT08-2DO |
PRWT12-2DC |
PRWT12-2DO |
PRWT12-4DC |
PRWT12-4DO |
PRWT18-5DC |
PRWT18-5DO |
PRWT18-8DC |
PRWT18-8DO |
PRWT30-10DC |
PRWT30-10DO |
PRWT30-15DC |
PRWT30-15DO |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Shield | Detection Head Size, Dimension M | Detection Head Size, Dimension D (Ø) | Detection Head Size, Dimension L2 (mm) | Standard Detector | Setting distance (mm) | Response frequency (Hz) | Response frequency (kHz) | Model configuration control output (or output) | Influence of temperature | Protection circuit | Wiring specifications |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
981,209 VND | 1 Piece(s) | 18 Day(s) | Shield | M8 | 15 | 30 | 8X8X1 mm (iron) | 0~1.05 | - | 1.5 | Normally Closed | ± 20 % or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit | φ4, 2 cores, 300 mm, M12 connector | ||
981,209 VND | 1 Piece(s) | 18 Day(s) | Shield | M8 | 15 | 30 | 8X8X1 mm (iron) | 0~1.05 | - | 1.5 | Normally Open | ± 20 % or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit | φ4, 2 cores, 300 mm, M12 connector | ||
981,209 VND | 1 Piece(s) | 18 Day(s) | Non-shield | M8 | 15 | 30 | 8X8X1 mm (iron) | 0~1.4 | - | 1 | Normally Closed | ± 20 % or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit | φ4, 2 cores, 300 mm, M12 connector | ||
981,209 VND | 1 Piece(s) | 18 Day(s) | Non-shield | M8 | 15 | 30 | 8X8X1 mm (iron) | 0~1.4 | - | 1 | Normally Open | ± 20 % or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit | φ4, 2 cores, 300 mm, M12 connector | ||
884,017 VND | 1 Piece(s) | 18 Day(s) | Shield | M12 | 21 | 42.5 | 12 x 12 x 1 mm (iron) | 0~1.4 | - | 1.5 | Normally Closed | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit | φ4, 2 cores, 300 mm, M12 connector | ||
884,017 VND | 1 Piece(s) | 18 Day(s) | Shield | M12 | 21 | 42.5 | 12 x 12 x 1 mm (iron) | 0~1.4 | - | 1.5 | Normally Open | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit | φ4, 2 cores, 300 mm, M12 connector | ||
884,017 VND | 1 Piece(s) | 18 Day(s) | Non-shield | M12 | 21 | 42.5 | 12 x 12 x 1 mm (iron) | 0~2.8 | 500 | - | Normally Closed | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit, overcurrent protection circuit | φ4, 2 cores, 300 mm, M12 connector | ||
884,017 VND | 1 Piece(s) | 18 Day(s) | Non-shield | M12 | 21 | 42.5 | 12 x 12 x 1 mm (iron) | 0~2.8 | 500 | - | Normally Open | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit, overcurrent protection circuit | φ4, 2 cores, 300 mm, M12 connector | ||
835,422 VND | 1 Piece(s) | 18 Day(s) | Shield | M18 | 29 | 47 | 18 x 18 x 1 mm (iron) | 0~3.5 | 500 | - | Normally Closed | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit, overcurrent protection circuit | φ5, 2cores, 300 mm, M12 connector | ||
835,422 VND | 1 Piece(s) | 18 Day(s) | Shield | M18 | 29 | 47 | 18 x 18 x 1 mm (iron) | 0~3.5 | 500 | - | Normally Open | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit, overcurrent protection circuit | φ5, 2cores, 300 mm, M12 connector | ||
835,422 VND | 1 Piece(s) | 18 Day(s) | Non-shield | M18 | 29 | 47 | 25X25X1 mm (iron) | 0~5.6 | 350 | - | Normally Closed | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit, overcurrent protection circuit | φ5, 2cores, 300 mm, M12 connector | ||
835,422 VND | 1 Piece(s) | 18 Day(s) | Non-shield | M18 | 29 | 47 | 25X25X1 mm (iron) | 0~5.6 | 350 | - | Normally Open | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit, overcurrent protection circuit | φ5, 2cores, 300 mm, M12 connector | ||
923,501 VND | 1 Piece(s) | 18 Day(s) | Shield | M30 | 42 | 58 | 30X30X1 mm (iron) | 0~7 | 400 | - | Normally Closed | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit, overcurrent protection circuit | φ5, 2cores, 300 mm, M12 connector | ||
923,501 VND | 1 Piece(s) | 18 Day(s) | Shield | M30 | 42 | 58 | 30X30X1 mm (iron) | 0~7 | 400 | - | Normally Open | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit, overcurrent protection circuit | φ5, 2cores, 300 mm, M12 connector | ||
923,501 VND | 1 Piece(s) | 18 Day(s) | Non-shield | M30 | 42 | 58 | 45X45X1 mm (iron) | 0~10.5 | 200 | - | Normally Closed | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit, overcurrent protection circuit | φ5, 2cores, 300 mm, M12 connector | ||
923,501 VND | 1 Piece(s) | 18 Day(s) | Non-shield | M30 | 42 | 58 | 45X45X1 mm (iron) | 0~10.5 | 200 | - | Normally Open | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit, overcurrent protection circuit | φ5, 2cores, 300 mm, M12 connector |
Loading...Tải…
Sensor Shape | Cylindrical type | Detection Object | Magnetic Metal | Operating Environment | Standard |
---|---|---|---|---|---|
Detection Type | Front detection | Sensor Case Material | Brass (Nickel-plated) | Sensor Detection Surface Material | PBT resin |
Amplifier | Built-in type | Acquired Standards | CE | Protection Structure (IEC) | IP67 |
Hysteresis distance | 10% or less of detection distance | Power Voltage (Operational Voltage Range) | 12-24VDC(10-30VDC) | Leakage current(mA) | 0.6 or less |
Residual Voltage(V) | 3.5 or less | Control Output(mA) | 2~100 | Insulation resistance(㏁) | 50 or more (500 VDC megger) |
Withstand Voltage | At 1,500 VAC 50/60 Hz for 1 min | Vibration resistant | 10-55 Hz (1 minute cycle) multiple amplitude 1 mm each X, Y, Z direction 2 hours | Impact resistance | 500 m/s² (approximately 50 G) 3 times for each X, Y, Z direction |
Indicator Lamp | Operation indicator (red LED) | Operating Ambient Temperature(℃) | -25 – 70, for storage: -30 – 80 | Operating Ambient Humidity(%RH) | 35-95, for storage: 35-95 |
Material | Nut: Nickel plated brass, Washer: Nickel plated iron, General type cable (Black): Polyvinyl chloride (PVC), Oil resistant reinforced cable (Gray): Polyvinyl chloride (oil resistance reinforced PVC) |
How can we improve?