(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Part Number |
---|
TM2-22CB |
TM2-22CE |
TM2-42CE |
TM4-N2SB |
TM4-N2SE |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Output Type | Number of Control Points | Weight (Package Box Excluded) (g) | The number of channels | CT input measurement level | Current Output Measurement Level | SSR control output | Control Output Current | Optional Output-Relay | Optional Output-Communication | Optional Input-CT Input | Optional Input-Digital Input | Adjustment Sensitivity | Sampling cycle (ms) | Insulation type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
5,291,684 VND | 1 Piece(s) | 5 Day(s) | SSR driving voltage / Current | 2 | Approx. 139 | 2-channel (interchannel isolation-withstanding voltage 1,000 VAC) | ±5% F.S. Below ±1 digit | ±1.5% F.S. Below ±1 digit | 12 VDC ±3 V 30 mA or less | Either DC 4-20 mA or DC 0-20 mA (load resistance 500 Ω or less) | 250VAC 3A 1a | RS485 communication output (Modbus RTU method) | 0.0-50.0 A (range of measurement of the value of primary circuit current) ※CT ratio: 1/1,000 | Contacted input: 1 kΩ or less when ON, 100 kΩ or more when OFF / Non-contacted input: Residual voltage at ON: 1.5 V or less, Leakage current 0.1 mA or less when OFF / bleeder current: approx. 0.5 mA per input | 1-100°C/°F (0.1-100°C/°F) variable | 50 (2-channel simultaneous sampling) | Power/Communication Connector | ||
5,116,877 VND | 1 Piece(s) | 5 Day(s) | SSR driving voltage / Current | 2 | Approx. 130 | 2-channel (interchannel isolation-withstanding voltage 1,000 VAC) | ±5% F.S. Below ±1 digit | ±1.5% F.S. Below ±1 digit | 12 VDC ±3 V 30 mA or less | Either DC 4-20 mA or DC 0-20 mA (load resistance 500 Ω or less) | 250VAC 3A 1a | RS485 communication output (Modbus RTU method) | 0.0-50.0 A (range of measurement of the value of primary circuit current) ※CT ratio: 1/1,000 | Contacted input: 1 kΩ or less when ON, 100 kΩ or more when OFF / Non-contacted input: Residual voltage at ON: 1.5 V or less, Leakage current 0.1 mA or less when OFF / bleeder current: approx. 0.5 mA per input | 1-100°C/°F (0.1-100°C/°F) variable | 50 (2-channel simultaneous sampling) | - | ||
5,465,237 VND | 1 Piece(s) | 7 Day(s) | SSR driving voltage / Current | 2 | Approx. 139 | 2-channel (interchannel isolation-withstanding voltage 1,000 VAC) | ±5% F.S. Below ±1 digit | ±1.5% F.S. Below ±1 digit | 12 VDC ±3 V 30 mA or less | Either DC 4-20 mA or DC 0-20 mA (load resistance 500 Ω or less) | 250VAC 3A 1a | RS485 communication output (Modbus RTU method) | 0.0-50.0 A (range of measurement of the value of primary circuit current) ※CT ratio: 1/1,000 | Contacted input: 1 kΩ or less when ON, 100 kΩ or more when OFF / Non-contacted input: Residual voltage at ON: 1.5 V or less, Leakage current 0.1 mA or less when OFF / bleeder current: approx. 0.5 mA per input | 1-100°C/°F (0.1-100°C/°F) variable | 50 (2-channel simultaneous sampling) | - | ||
6,509,491 VND | 1 Piece(s) | 5 Day(s) | SSR driving voltage | 1 | Approx. 160 | 4-channel (interchannel isolation-withstanding voltage 1,000 VAC) | - | - | 22 VDC ±3 V 30 mA or less | - | - | - | - | - | 1~100 digit | 100 (4 channel simultaneous sampling) | Power/Communication Connector | ||
6,161,268 VND | 1 Piece(s) | 5 Day(s) | SSR driving voltage | 1 | Approx. 150 | 4-channel (interchannel isolation-withstanding voltage 1,000 VAC) | - | - | 22 VDC ±3 V 30 mA or less | - | - | - | - | - | 1~100 digit | 100 (4 channel simultaneous sampling) | - |
Loading...Tải…
Input Method | Thermocouple / Thermoresistor | Control Method | ON/OFF control / PID control with auto tuning / PID control with self-tuning / PI control / PD control / P control | Number of Input Points(pcs.) | 2 |
---|---|---|---|---|---|
Setting Method | Key Input / RSP input | Input Voltage | 24VDC::24VDC | Failure Detecting Function | Heater Single Wire |
Acquired Standards | UL / CE | Allowable voltage fluctuation range | About 90 to 110% of Power Supply Voltage | Power Consumption | 5 W or less |
Display Mode | No display - Parameter setting and monitoring from external devices (PC, PLC, etc.) | Insulation resistance | 100 MΩ or more (500 VDC Megger) | Withstand Voltage | At 1,000 VAC 50/60 Hz for 1 min (between input terminal and power terminal) |
Noise resistant | Square wave noise (pulse width 1 μs) by noise simulator ±0.5 kV | Vibration resistant | 5–55 Hz (1 minute cycle) multiple amplitude 0.75 mm each X, Y, Z direction 2 hours | Operating Ambient Temperature(℃) | -10 - 50, for storage: -20 - 60 |
Operating Ambient Humidity(%RH) | 35-85, for storage: 35-85 | Thermoresistor Measurement Precision | (A larger one of ±0.5% or ±1°C of PV) below±1 digit | Thermocouple measurement | (A larger one of ±0.5% or ±1°C of PV) below±1 digit |
Temperature Effect | (The larger one of ±0 5% or ±2°C of PV) below ±1 digit (provided, in thermocouple input, below -100°C should be within ±5°C) / thermocouple L, U, C, G, R, S, B (The larger one of ±0.5% or ±5°C) should be below ±1 digit | Thermoresistor Input Sensor | DPt100 Ω, JPt100 Ω 3-wire type (allowable line resistance of 5 Ω or less per wire) | Thermocouple input sensor | K, J, E, T, L, N, U, R, S, B, C, G, PLII (13 types) |
Proportional bandwidth (P) | 0.1~999.9℃/℉ | Integral Time (l)(Seconds) | 0~9999 | Derivative time (D)(Seconds) | 0~9999 |
Control Period (T)(Seconds) | 0.1-120.0 (Relay output, only for SSR driving voltage output) | Manual reset value(%) | 0.0~100.0 | Mechanical relay life | 10 million times or more |
Electrical Relay Life | 100,000 times or more (250 VAC 3 A resistance load) | Accessories | Connection Connector for Expansion | Major Characteristics | Input / output control of multi channels available with one product / High speed sampling control available / Communication and power wiring between modules not requiring due to expansion through the connecting connector between modules: Expandable up to maximum 31 units / Insulation structure design between input channels (withstand voltage 1,000 VAC) / Parameter configuration available using SCM-US without supplying power or connecting wires |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy