(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Caution
thận trọng
2 port solenoid valve employing pilot kick system. Series provided respectively for compressed air, water and steam. Can operate from differential pressure 0 as it uses a pilot kick system.
Note: CAD data of this series is being revised. Please wait till the corrections are done.
Item | PKA-04-27 | PKA-06-27 | PKA-10-27 | PKA-12-27 | PKA-14-27 | PKA-20-25 | |
---|---|---|---|---|---|---|---|
Operating fluid | Air | ||||||
Connection port diameter | Rc1/2 | Rc3/4 | Rc1 | 32 flange | 40 flange | 50 Flanges | |
Orifice diameter mm | 15 | 20 | 25 | 35 | 40 | 50 | |
C [dm^3/(s*bar)] | 20 | — | — | — | — | — | |
b | 0.30 | — | — | — | — | — | |
s (mm^2) | — | 128 | 220 | 404 | 552 | 883 | |
Operating pressure difference MPa | 0 to 0.7 | 0 to 0.5 | |||||
Pressure resistance (water pressure) MPa | 1.5 | 1.0 | |||||
Fluid temperature °C | 5 to 60 | ||||||
Ambient temperature (°C) | 0 to 65 | 0 to 45 | 0 to 40 | ||||
Valve seat leakage cm^3/min | 1 or less, 400 or less for stainless steel (*1) | 2 or less (*1) | |||||
Mounting orientation | Limited to the vertical posture with the coil area facing up. | ||||||
Weight (kg) | 1.8 | 2.2 | 2.9 | 9 | 10 | 13 | |
Electrical Specifications | |||||||
Rated Voltage | 100 V AC 50/60 Hz, 200 V AC 50/60 Hz | ||||||
Apparent power VA | When holding | 30 | 75 | 90 | |||
At startup | 80 | 150 | 180 | ||||
Power consumption W | 22 | 57 | 68 | ||||
Heat-resistant class | Class 130 (B) |
*1: PKA-04 to 14 values are for pneumatic pressure of 0.05 to 0.7 MPa, and PKA-20 values are for pneumatic pressure of 0.05 to 0.5 MPa. With 0.05 MPa or less pressure, the seal will be unstable.
*2: The conversion between the effective cross-sectional area S and the sonic conductance C is S ≈ 5.0 × C.
Internal Structure
Product number | Part name | Materials | |
---|---|---|---|
1 | Coil | — | — |
2 | Core assembly | SUS405 or equivalent, SUS316L | Stainless steel |
3 | Shading coil | Cu (Ag) | Copper (Silver) |
4 | Plunger | Equivalent to SUS405 | Stainless steel |
5 | Gasket | Inorganic fiber (PTFE) | — (Polytetrafluoroethylene) |
Product number | Part name | Materials | |
---|---|---|---|
6 | Spring | SUS304 | Stainless steel |
7 | Main valve | C3604·NBR (SUS304, PTFE) | Brass / nitrile rubber (Stainless steel, polytetrafluoroethylene) |
8 | Body | CAC408 (SCS13) | Bronze casting (Stainless Steel Cast Iron) |
9 | Bolt | SWRM (SUS304) | Steel (stainless steel) |
The numbers in the parentheses are for stainless steel body materials.
PKA-04 to 10-27
PKA-12 to 20-27 (25)
* d indicates the connection port diameter (Refer to the above specifications.)
Model | A | B | C | D | E | F | G | H |
---|---|---|---|---|---|---|---|---|
PKA-04-27 | 90 | 126 | 29 | 88 | 23 (27) | — | 60 | 49 |
PKA-06-27 | 100 | 133 | 35 | 95 | 26 (29) | — | 60 | 49 |
PKA-10-27 | 110 | 145 | 44 (46) | 107 | 30 (33) | — | 60 | 49 |
PKA-12-27 | 170 | 180 | 135 | 128 | — | 100 | 84 | 66 |
PKA-14-27 | 180 | 185 | 140 | 133 | — | 105 | 84 | 66 |
PKA-20-25 | 180 | 205 | 155 | 155 | — | 120 | 84 | 66 |
The dimensions in the parentheses are for stainless steel body materials.
Part Number |
---|
PKA-20-25-AC200V |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Voltage | Pipe Port Type | Plumbing Thread Nominal | Body Material |
---|---|---|---|---|---|---|---|---|
14,808,262 VND | 1 Piece(s) | 18 Day(s) or more | AC200V | [Others] 50 Flanges | - | Bronze |
Loading...Tải…
Type | Electromagnetic Valve | Application | Single Item Operating | Number of Ports | 2-port valve |
---|---|---|---|---|---|
Mounting Orientation | Direct | Specifications | Standard | Number of Solenoids | Single |
Switching Type | 2-position Normally Closed | Status at Power Off | Self-reset(spring return) | Plumbing | Direct piping |
Driving Type | Pilot-Operated Poppet | Seal Type | Soft seal |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy