(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.

  • Viewed
    Products
    Sản phẩm
    đã xem
    최근 본
    상품
    查看产品 查看產品
  • My
    Components
    Linh kiện
    của tôi
    나의 부품 我的部件 我的部件
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • [Cảnh Báo] Thủ Đoạn Lừa Đảo Từ Nhân Viên Giao Hàng – Yêu Cầu Trả Phí Ship. Xem chi tiết.
    [Warning] Fraud Calling from Shipper - Asking to Pay Shipping Fee. See more.

Manual Rotary Stages Running-In Installation Type (E-RPG38-NR)

Manual Rotary Stages Running-In Installation Type (E-RPG38-NR)

Click this image to zoom it.Nhấp vào hình ảnh này để phóng to.

Move the mouse over or click the image to zoom

  • Manual Rotary Stages Running-In Installation Type (E-RPG38-NR)
  • Manual Rotary Stages Running-In Installation Type (E-RPG38-NR)
  • Volume Discount
You can add up to 6 items per a category to the compare list.

Part Number :
    • From :
      1,113,424VND/Unit
  • Order Qty :
  • Total Price :
    ---
  • Days to ship :
    ---

Select part number to Order Now/ Add to Cart

(i)

Caution

thận trọng

  • **RoHS Compliant is available for some part numbers.
    Please contact with MISUMI for detail effective date.


Product Overview
MISUMI E-RPG series manual rotary stages is an economy series stage. It can be used as a positioning stage for simple position adjustment. The body is made of aluminum alloy to achieve light weight; the surface is black anodized. Prices have been significantly reduced due to local production in China and improved machining process.
Dimensional Drawing
MISUMI Economy series Manual X-Axis Rotary Stages E-RPG Series Dimensional Drawing
Specifications Overview
Type Material Surface TreatmentMovement (mm)Load Capacity (N)Lateral Misalignment
E-RPGAluminum AlloyBlack AnodizedRough Adjustment 360°
Fine Adjustment±5°
9.8~78.4Within 30 μm

■Amount of travel
The catalog drawing size is the state of travel 0°, and taking this as reference, the degrees rotated in the left and right directions is the amount of travel.

■Load capacity
is the force in N that the positioning stage can withstand when the center of gravity of the workpiece is in the center of the positioning stage. If used in excess of the load capacity, the positioning stage may not move properly or get stuck. Refer to the values of "Horizontal" and "Vertical" for the load resistance for horizontal and vertical installation respectively. Note that when the linear motion positioning stage is installed vertically or upside down, the accuracy may be less than the value indicated in the catalog.

■Lateral misalignment
refers to the amount of deviation from the rotation center.
Specification Table
Part Number
E-RPG38
 
Part NumberStage Surface (mm)Travel DistanceMinimum ReadingLoad Capacity (N)Lateral Misalignment (μm)Weight (kg)
TypeNo.Vernier CaliperMicrometerHorizontal
E-RPG38Φ38Rough Adjustment 360°
Fine Adjustment±5°
0.2°≈1'44"/Scale9.8300.1
60Φ60≈92"/Scale29.40.3
80Φ800.1°≈67"/Scale39.20.52
85Φ85≈72"/Scale39.20.51
90Φ90≈61"/Scale490.62
100Φ100≈56"/Scale490.72
110Φ110≈57"/Scale490.8
125Φ125≈46"/Scale491.2
160Φ160≈36"/Scale78.41.74

■Alteration
AlterationChanging the position of the micrometer knob
Spec.Side Left and Right ReverseMISUMI E-RPG Series Positioning Stages Alteration
CodeNR
The mounting dimensions of micrometer knob and clamp are different from standard products. Please confirm the detailed dimensions according to CAD data.
Product Features
Feature 1: The body is made of aluminum alloy to achieve light weight
Feature 2: Low price is achieved by simplifying the structure and improving the machining process.
Feature 3: Through holes are set to enable cable routing, positioning of rotary polarization elements, etc.
Feature 4: By improving the clamping mechanism, the holding force of the positioning stage is greater than that of the standard type clamping mechanism.
Example of Use
MISUMI Case Study on the Use of Economy Series Manual Positioning StagesMechanism name: Temperature sensor position adjustment during thermal crimping of camera module

Rotary stage used: E-RPG60

Purpose: Combined with straight operation XZ-axis dovetail stage to control the sensor detection angle for accurate measurement.
Usage Method
■Installation Method of Rotary Stage
When mounting the stage to the base, basically it is mounted by moving the stage surface. Refer to the following diagram.
Installation Method of MISUMI Manual X-Axis Rotary Stage
The above diagram is for demonstration purpose only. Refer to each catalog or 3D data for detailed shapes and specifications of the positioning stage.
Precautions for Surface Precision of Mounting Part
 When the components mounted on the bottom or top of the positioning stage are not flat enough, the product may fail to operate with intended performance. (Reference standard of flatness: within 10μm)

■Mounting posture of rotary stage
Load capacity and accuracy will change greatly due to its mounting posture. Please use the following characteristics table as rough reference for the usability in a particular mounting posture.
The rotary stage cannot be mounted inversely, or its performance may change greatly.
It can be side-mounted, but can be used only when the load is applied in the direction of micrometer knob; it cannot be used for applications where no load is applied to the micrometer knob (see the diagram below).
 
Installation Method of MISUMI Manual X-Axis Rotary Stage

NG
Installation Method of MISUMI Manual X-Axis Rotary Stage

NG
  
Application Industries
Electronics/Home Appliance Automotive Medical
Application Scenario Diagram of MISUMI Manual Positioning Stages in Electronics and Home Appliance Fields Application Scenario Diagram of MISUMI Manual Positioning Stages in Automotive Industry Application Scenario Diagram of MISUMI Manual Positioning Stages in Medical Device Industry
Smart Phones Semiconductor Lithium battery
Application Scenario Diagram of MISUMI Manual Positioning Stages in Smart Phone Industry Application Scenario Diagram of MISUMI Manual Positioning Stages in Semiconductor Industry Application Scenario Diagram of MISUMI Manual Positioning Stages in Lithium-Ion Battery Industry

Part Number 

  • Incomplete part number.
    Please use left hand selections to complete a part number.
    Incomplete part number.
    Please use left hand selections to complete a part number.
Loading...Tải…
Part Number
E-RPG38-NR
Part NumberPriceMinimum Order Qty.Volume DiscountDays to ShipSố ngày giao hàngTable Size (Dia.) D
(Ø)
Position Change of Micrometer Knob

1,113,424 VND

1 Piece(s) Available 16 Day(s) 38NR (Side Left and Right Reverse Type)

Loading...Tải…

  1. 1

Please check the type/dimensions/specifications of the part E-RPG38-NR in the Manual Rotary Stages Running-In Installation Type series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần E-RPG38-NR trong chuỗi Manual Rotary Stages Running-In Installation Type.

Frequently asked question (FAQ)FAQ

Question:Question: When a rotary stage is finely adjusted using a micrometer knob, how many degrees will the stage surface rotate as the micrometer knob moves 1mm?
Answer:Answer: The micrometer knob moves 6.5mm as the stage surface rotates 10°. In other words, the stage surface rotates 1.538° as the micrometer knob moves 1mm.
Question:Question: What is the difference between lateral misalignment and surface runout of a rotary stage?
Answer:Answer: Lateral misalignment refers to the displacement of a rotating central shaft in horizontal direction. Surface runout refers to the max. displacement difference relative to the reference plane after rotating one full turn, taking the outer edge of the stage moving surface fixed on the reference surface as the point of measurement. Both are in the unit of μm.
Question:Question: When using a manual rotary stage, is it normal that the clamping device on the opposite side of the micrometer knob still moves even locked after positioning?
Answer:Answer: MISUMI manual rotary stages can be finely adjusted after rough positioning. First of all, please lock the rough adjusting & clamping part according to the following steps: ①Adjust the feeding part to the destination (360° adjustable) ②Lock and fix the rough adjusting & clamping part ③Adjust the micrometer to the destination ④Lock the fine adjusting & clamping part.
Question:Question: Does a reverse manual rotary stage also have a reverse direction (counterclockwise) of reading (0~360°)?
Answer:Answer: The direction of reading (0~360°) is clockwise for both R (forward) and L (reverse)?

Check other FAQ (1 items) HideĐóng.

Products like this...

Part Number
E-RPG110-NR
E-RPG125
E-RPG125-NR
E-RPG60-NR
E-RPG80
E-RPG80-NR
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipSố ngày giao hàngTable Size (Dia.) D
(Ø)
Position Change of Micrometer Knob

2,916,390 VND

1 Piece(s)Available 16 Day(s) 110NR (Side Left and Right Reverse Type)

3,803,392 VND

1 Piece(s)Available 16 Day(s) 125Standard

3,803,392 VND

1 Piece(s)Available 16 Day(s) 125NR (Side Left and Right Reverse Type)

1,476,986 VND

1 Piece(s)Available 16 Day(s) 60NR (Side Left and Right Reverse Type)

2,276,596 VND

1 Piece(s)Available 16 Day(s) 80Standard

2,276,596 VND

1 Piece(s)Available 16 Day(s) 80NR (Side Left and Right Reverse Type)