MISUMI Việt Nam đồng hành cùng Kỹ sư tương lai trong cuộc thi SMAE Award 2024.
Xem chi tiết.
MISUMI Vietnam accompanies Future Engineers in the SMAE Award 2024 competition.
See more.
Thermometers/Hygrometers(Measured humidity range:15 to 95)
Thermometers and hygrometers are measuring equipment used to measure temperature and humidity. Depending on the product, they can measure indoor temperature and humidity, surface temperature of objects, temperature of liquids, and the like. Thermo‑hygrometers, which can measure temperature and humidity at the same time, come in 2 types: analog and digital. Bimetal thermometers are products that have 2 strips of metal with different thermal expansion coefficients bonded to sense temperature by the expansion of the metals. The structure is simple, so maintenance is easy, and durability is high, so they are often used for industrial purposes. Radiation thermometers can measure without contacting the object to measure by radiating infrared rays. Remote thermometers measure temperature of distant objects, and analog and digital types can be selected. The temperature range that can be measured is determined by the measuring equipment, so the product must be selected according to its purpose.
Brand |
-
A&D (2)
-
AIDENSHIGIKEN (0)
-
ANRITSUKEIKI (0)
-
AS ONE (0)
-
ASEIKOGYO (0)
-
ASIAN FIRST (0)
-
BLUEBIRD (0)
-
CUSTOM (0)
-
DRETEC (0)
-
ESCO (0)
-
FLIR (0)
-
FUJITADENKI (0)
-
FUSO (0)
-
HOZAN (0)
-
LINESEKI (0)
-
MOTHERTOOL (0)
-
NETSUKEN (0)
-
NICHIYUGIKEN (0)
-
NIKKATO (0)
-
OPTEX (0)
-
SATO KEIRYOKI (0)
-
SEKONIC (0)
-
SHINWASOKUTEI (0)
-
T&D (0)
-
TANITA (0)
-
TEMPIL (0)
-
TESTO (0)
-
TGK (0)
-
TOKYO TECHNOLOG (0)
-
TPI (0)
-
TRUSCO NAKAYAMA (0)
|
CAD |
|
Days to Ship |
- All
- Same day
- 4 Day(s) or Less
- 5 Day(s) or Less
- 6 Day(s) or Less
- 7 Day(s) or Less
- Others
|
-
Thermometer and Hygrometer with External Sensors, AD-5682 (with Clock)
A&D
A thermometer that simultaneously displays temperature, humidity, and time, as well as switching between indoor and outdoor temperature.[Features]· Ideal for time and temperature control, one technique for food hygiene management.· Max/min temperature and humidity can be recorded automatically.· Temperatures in other locations can also be measured with the external sensor. (The external temperature sensor cable length is 3 m, and it can be removed)· With hook socket for tabletop and wall-mounting on the back surface of the main body.[Applications]· For managing heat and working environments in factories, etc.· Used for temperature/humidity/time management in gymnasiums, auditoria, etc.· Hygiene management in food manufacturing, etc., and in food preparation / kitchens.
From:
1,038,593 VND
|
Days to Ship:
Số ngày giao hàng:
4 Day(s) or more
|
4 Day(s) or more
-
Thermometer and Hygrometer with External Sensors, AD-5648A (Dual Channel)
A&D
2-channel temperature and humidity meter which can display temperature and humidity of 2 places at the same time with inner and outer sensors.[Features]· The external temperature and humidity sensor cable is approx. 3 m long and removable.· Max/min temperature and humidity automatic memory.· Can be used while hanging on the wall or placed atop a desk.[Applications]· For labs and factories, etc.· For homes, nursing facilities, schools, etc.· Temperature and humidity control of food products, medicines, and so on.· For temperature/humidity management of agricultural crops when raising seedlings, growing crops, etc.
From:
1,416,577 VND
|
Days to Ship:
Số ngày giao hàng:
6 Day(s) or more
|
6 Day(s) or more
|
---|
BrandNhãn hiệu |
---|
Product SeriesDòng sản phẩm |
---|
From |
---|
Days to ShipSố ngày giao hàng |
---|
Product Type
|
---|
Temperature Measuring Range(°C)
|
---|
Temperature minimal display(°C)
|
---|
Drip-proof and Waterproof function
|
---|
Operating Temperature Range(°C)
|
---|
Humidity Minimal Display(%RH)
|
---|
Measured humidity range(%RH)
|
---|
Heat Stroke Index display range(°C)
|
---|
Primary Color
|
---|
Color after discoloration
|
---|
| | |
---|
BrandNhãn hiệu | A&D | A&D |
---|
Product SeriesDòng sản phẩm | Thermometer and Hygrometer with External Sensors, AD-5682 (with Clock) | Thermometer and Hygrometer with External Sensors, AD-5648A (Dual Channel) |
---|
From |
1,038,593 VND
|
1,416,577 VND
|
---|
Days to ShipSố ngày giao hàng |
4 Day(s) or more
|
6 Day(s) or more
|
---|
Product Type | Thermo-hygrometer (External Sensor Type) | Thermo-hygrometer (External Sensor Type) |
---|
Temperature Measuring Range(°C) | 0 to 50 (Internal) / -40 to 70 (external) | 0 to 50 |
---|
Temperature minimal display(°C) | 0.1 | 0.1 |
---|
Drip-proof and Waterproof function | NA | NA |
---|
Operating Temperature Range(°C) | - | - |
---|
Humidity Minimal Display(%RH) | 1 | 1 |
---|
Measured humidity range(%RH) | 15 to 95 | 15 to 95 |
---|
Heat Stroke Index display range(°C) | - | - |
---|
Primary Color | - | - |
---|
Color after discoloration | - | - |
---|
Loading...Tải…
Specification/DimensionsĐặc điểm kỹ thuật / Kích thướcĐặc điểm kỹ thuật / Kích thước
-
Product Type
-
Thermometer
-
Thermo-hygrometer
-
Thermometer (External Sensor Type)
-
Thermo-hygrometer (External Sensor Type)
-
Core temperature thermometer
-
Built-in thermometer
-
Radiation thermometer
-
Condensation Checker
-
Thermometer (Installation Type)
-
Thermo-hygrometer (Logger)
-
Thermo-hygrometer_
-
Heat Sensor
-
Heat Stroke Index monitor
-
Temperature Indicating Material For Temperature Management
-
Other Accessory
-
Soil acidity meter
-
Temperature Measuring Range(°C)
- -200 to 300
- -200 to 500
- -200~1370
- -200~1372
- -199.9 to +500.0
- -199.9~1370
- -195~450
- -100 to +100
- -100 to +260
- -100 to +300
- -100~300
- -100~360
- -100 to +400
- -100~400
- -99.99 to +400.0
- -70 to +200
- -60~76
- -60 to 155
- -60 to 500
- -60~500
- -60~550
- -60~625
- -60 to 1500
- -59.9 to +99.9
- -56 to +306
- -55 to 220
- -55~220
- -50~50
- -50.0 to +70.0
- -50 to +70
- -50~70
- -50~90
- -50~110
- -50 – 150
- -50~150
- -50~190
- -50.0~199.9
- -50.0 to +199.9, +200 to +1,000 (accuracy: ±1.2)
- -50 to 200
- -50 to +200
- -50 to 250
- -50 – 250
- -50 to +260
- -50 to +280
- -50~280
- -50~288
- -50 to 300
- -50 to +300
- -50 – 300
- -50~350
- -50 to 400
- -50~450
- -50~480
- -50 to 500
- -50 – 500
- -50 to 800
- -50~900
- -50 to 1300
- -50~1300
- -45~95
- -40 to 50
- -40 to 69.9
- -40 to +70
- -40 ~ 70
- -40~70
- -40 – 80
- -40 to 99.9
- -40 – 100
- -40 to 110
- -40 – 120
- -40 to +200
- -40~200
- -40~250
- -40~+250℃
- -40 to +300
- -40~+300℃
- -40~500
- -40~+500℃
- -40 to 800
- -40 to +800
- -40~+800℃
- -40~+900℃
- -38 ~ 365
- -35-560 (Contactless), -100-1,200 (Contact Type)
- -35~1,500
- -33~180
- -33~220
- -33 – 220 (Radiation Thermometer) / -55 – 330 (Core Thermometer)
- -30 to 50
- -30~50
- -30~70
- -30 to +200
- -30~200
- -30~250
- -30 to +280
- -30~480
- -30 to 500
- -30~600
- -28~48
- -24~44
- -24 to 50
- -20-55
- -20~1,000
- -20 to 40
- -20~40
- -20~50
- -20~55
- -20 – 60
- -20.0~60.0
- -20 – 70
- -20 – 80
- -20 – 100
- -20~200
- -20~400
- -20~450
- -20~600
- -19.5~99.9
- -18~1350
- -18~1650
- -15 to 40
- -10-50 (Sensor: -20 - 1000)
- -10 to 40
- -10 to 50
- -10.0 to +50.0
- -10 – 50
- -10~50
- -10.0~50.0
- -10 to 50 (internal) / -50 to 70 (external)
- -10.0~60.0
- -10~110
- -10 to +200
- -9.9 to +50.0
- -9.9~50
- -9.9~99.9
- -5 to 50
- -5 – 50
- Refrigerator Room Outside (OUT): -5 - 50, Refrigerator Storage Inside (IN): -50-70
- 0 to +1,000
- 0–40
- 0 to 50
- 0~50
- 0–50
- 0 to 50 (Internal) / -40 to 70 (external)
- Internal Sensor Temperature (TA): 0 to 50, Probe Sensor Temperature (T1/T2): -40 to 70
- 0 to 55
- 0 to 55 (Thermistor)
- 0–80
- 0–90
- 0–100
- 0–150
- 0–200
- 0 to +300
- 0–300
- 0 to +400
- 0–500
- 0 to +600
- 0 to +800
- 1°C Resolution: -200 to 1,370°C/0.1°C Resolution: -104.9 to 504.9°C
- 1°C Resolution: -200 to 800°C/0.1°C Resolution: -104.9 to 504.9°C
- -50~400
- 100–200
- 143 to 166
- MAX180
- 199 to 224
- -200~300
- -200~500
- 232 to 260
- 232 to 283
- MAX400
- MAX500
- MAX650
- MAX1000
-
Temperature minimal display(°C)
- -50
- -35 to 999.9: 0.1, Other: 1
- -19.9 to 199.9: 0.1, Other: 1
- -9.9 to 199.9: 0.1/Otherwise: 1
- 0.01
- 0.1
- 0.1 (-60°C to + 999.9°C), otherwise 1
- 0.1 (-55.0 to 199.9), 1 (Other measurement range)
- 0.1 (-50 to 199.9), 1 (-50 to 1,300) (Toggle resolution with toggle switch)
- 0.1 (-50 to 199.9), 1 (outside of -50 to 199.9)
- 0.1 (-33°C to +199.9°C), Otherwise 1
- 0.1 (-20 to 200)
- 0.1 (-9.9°C to +199.9°C), Otherwise 1
- 0.1 (-9.9°C to +199.9°C), otherwise 1
- 0.1/1
- Internal Sensor Temperature (TA): 0.1, Probe Sensor Temperature (T1/T2): 0.1
- 0.2 0.2 (-9.8°C to +180.0°C), Otherwise 1
- 1
- IN・OUT:1 MAX・MIN:1
- 2
- 5
- 143
- 199
- 232
-
Drip-proof and Waterproof function
-
Drip-Proof
-
Waterproof
-
Drip-proof and Waterproof
-
NA
-
Operating Temperature Range(°C)
- -40~200
- -40~250
- -40~300
- -40~500
- -40~700
- -40~800
- -40~1000
- -40~1200
- -30~50
- -30~250
- -20 – 50
- -10 to +50
- -10.0 to +50.0
- -10 – 50
- -10 to +60
- -10~+60
- -10~110
- -9.9 to 50.0
- 0 to 50
- 0 to +50
- 0–50
- 0–200
- 0–400
- 0–700
- 0–800
- 0–1200
- 1,000
- 10–40
- 20 ±10
- 50~100
- 250
- 300
- 400
- 500
- 600~900
- 800
- 800~1150
- 1050~1300
- 1200~1500
- 1400~1700
-
Humidity Minimal Display(%RH)
- 0.01
- 0.1
- 1
- Internal Sensor Humidity (RH): 1% RH
- 2
- 3
- 5
-
Measured humidity range(%RH)
- 0-100
- 0 to 100
- 0–100
- 5~90
- 5~95
- 5~98
- 5.0~99.9
- 5~100
- 10・20・30・40・50・60
- 10 to 90
- 10–90
- 10 to 95
- 10~95
- 10 to 100
- 15 to 95
- 15~100
- 20-98 (For 0-50°C Display Temperature)
- 20 to 90
- 20~90
- Internal Sensor Humidity (RH): 20 to 90
- 20 to 95
- 20~95
- 20~95
- 20.0~95.0(at23)
- 20~98
- 20~99
- 20 to 100
- 20~100
- 25 to 95
- 30~95
- 70
- 70/80/90
- 80
-
Heat Stroke Index display range(°C)
- -2 to 60
- -2 to 62
- IN:0~59/OUT:0~56
- 0–60
-
Primary Color
-
Color after discoloration
Related Categories to Thermometers/HygrometersDanh mục liên quan đến Thermometers/Hygrometers
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy