(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.

  • Viewed
    Products
    Sản phẩm
    đã xem
    최근 본
    상품
    查看产品 查看產品
  • My
    Components
    Linh kiện
    của tôi
    나의 부품 我的部件 我的部件
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • [Thông Báo] Xác Nhận Dữ Liệu Người Dùng Web, Phục Vụ Dự Án Hỗ Trợ Chat Qua Zalo OA. Xem chi tiết.
    [Announcement] User Data Confirmation for the Chat Support Project via Zalo OA. See more.

Earth Leakage Breakers (Low Capacity)(Mounting Method:DIN/Screw retention)

Earth Leakage Circuit Breakers (ELCB), also known as an earth leakage switch or earth leakage protector, is an electrical safety device that detects and protects against electrical shock hazards caused by leakage current. When selecting an Earth Leakage Circuit Breaker (ELCB), it is crucial to consider factors such as Ampere frame, Number of Poles, Rate Current, Rate Operating, Voltage, Mounting Method (e.g., DIN rail mount, Fasten with screws, and etc.), and Size (height , width and depth). These considerations are vital for ensuring the production of high-quality products. We highly recommend reputable brands like MITSUBISHI , FUJI ELECTRIC , and NITTO KOGYO
Take advantage of the convenience of FREE SHIPPING and NO MINIMUM ORDER on the Earth Leakage Circuit Breaker (ELCB). If you have any doubts or require assistance in choosing the right product, our experts are readily available to provide advice and guidance.
CAD
Days to Ship
  • All
  • 4 Day(s) or Less
  • 7 Day(s) or Less
  • 10 Day(s) or Less
  • 14 Day(s) or Less
  • 20 Day(s) or Less
  • Others

9 itemsMặt hàng

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    Earth Leakage Circuit Breaker F Style NV-S Class (General-Purpose Product) Harmonic/Surge Compatible Type NV32-SVF

    Earth Leakage Circuit Breaker F Style NV-S Class (General-Purpose Product) Harmonic/Surge Compatible Type NV32-SVF

    MITSUBISHI

    The industry's smallest breaker was born. F Style NV-S class (general-purpose)

    Ampere frame AF Rated block capacity AC 100 V(kA) Rated block capacity AC 200 V(kA) Rated block capacity AC 400 V(kA) Number of Poles Rated Operating Voltage(V) Rated Current(A) rate sensitivity current(mA) Mounting Method Representative Standard Dimension height(mm) Dimension width(mm) Dimension depth(mm) Rated block capacity, voltages except VAC 100/200/400, VDC 250 Connection Method
    30AF or less 7.5 7.5 5 2 / 3 AC100-440 ~ AC100 to 440 10 ~ 30 30 ~ 500 DIN/Screw retention PSE / CE / TUV 100 36 ~ 54 90 Available Surface type
    From: 1,572,500 VND
    Days to Ship: Số ngày giao hàng: Quote
    day to ship Quote
  • You can add up to 6 items per a category to the compare list.

    Earth Leakage Circuit Breaker F Style NV-C Class (Economy Product) Harmonic/Surge Compatible Type NV63-CVF

    Earth Leakage Circuit Breaker F Style NV-C Class (Economy Product) Harmonic/Surge Compatible Type NV63-CVF

    MITSUBISHI

    The industry's smallest breaker was born. F Style NV-C Class (economic item)

    Ampere frame AF Rated block capacity AC 100 V(kA) Rated block capacity AC 200 V(kA) Rated block capacity AC 400 V(kA) Number of Poles Rated Operating Voltage(V) Rated Current(A) rate sensitivity current(mA) Mounting Method Representative Standard Dimension height(mm) Dimension width(mm) Dimension depth(mm) Rated block capacity, voltages except VAC 100/200/400, VDC 250 Connection Method
    50AF 7.5 7.5 5 2 / 3 AC100-440 ~ AC100 to 440 15 ~ 50 30 DIN/Screw retention PSE 100 36 ~ 54 90 - Surface type
    From: 2,612,500 VND
    Days to Ship: Số ngày giao hàng: Quote
    day to ship Quote
  • You can add up to 6 items per a category to the compare list.

    Circuit breaker for control panel FA series (Earth leakage circuit breaker) NV30-FA

    Circuit breaker for control panel FA series (Earth leakage circuit breaker) NV30-FA

    MITSUBISHI

    Leakage breaker for control panel, NV-FA type

    Ampere frame AF Rated block capacity AC 100 V(kA) Rated block capacity AC 200 V(kA) Rated block capacity AC 400 V(kA) Number of Poles Rated Operating Voltage(V) Rated Current(A) rate sensitivity current(mA) Mounting Method Representative Standard Dimension height(mm) Dimension width(mm) Dimension depth(mm) Rated block capacity, voltages except VAC 100/200/400, VDC 250 Connection Method
    30AF or less 2.5 2.5 - 2 AC100 to 200 15 30 DIN/Screw retention PSE 72 40 73.5 - Surface type
    From: 1,602,500 VND
    Days to Ship: Số ngày giao hàng: Quote
    day to ship Quote
  • You can add up to 6 items per a category to the compare list.

    Earth Leakage Circuit Breakers (ELCB) NV-SVFU Series

    Earth Leakage Circuit Breakers (ELCB) NV-SVFU Series

    MITSUBISHI

    Ampere frame AF Rated block capacity AC 100 V(kA) Rated block capacity AC 200 V(kA) Rated block capacity AC 400 V(kA) Number of Poles Rated Operating Voltage(V) Rated Current(A) rate sensitivity current(mA) Mounting Method Representative Standard Dimension height(mm) Dimension width(mm) Dimension depth(mm) Rated block capacity, voltages except VAC 100/200/400, VDC 250 Connection Method
    50AF 15 - 10 2 / 3 AC120-240 5 ~ 50 30 DIN/Screw retention PSE / CE / TUV / CCC 120 36 ~ 54 90 Available Surface type
    From: 5,410,000 VND
    Days to Ship: Số ngày giao hàng: Quote
    day to ship Quote
  • You can add up to 6 items per a category to the compare list.

    Earth Leakage Circuit Breakers (ELCB) NV-CVFU Series

    Earth Leakage Circuit Breakers (ELCB) NV-CVFU Series

    MITSUBISHI

    Ampere frame AF Rated block capacity AC 100 V(kA) Rated block capacity AC 200 V(kA) Rated block capacity AC 400 V(kA) Number of Poles Rated Operating Voltage(V) Rated Current(A) rate sensitivity current(mA) Mounting Method Representative Standard Dimension height(mm) Dimension width(mm) Dimension depth(mm) Rated block capacity, voltages except VAC 100/200/400, VDC 250 Connection Method
    100AF to 199AF 15 - 10 3 AC120-240 60 ~ 100 30 ~ 100· 200· 500 switch DIN/Screw retention PSE / CE / TUV 150 75 90 Available Surface type
    From: 5,956,250 VND
    Days to Ship: Số ngày giao hàng: Quote
    day to ship Quote
  • You can add up to 6 items per a category to the compare list.

    Earth Leakage Circuit Breaker Supporting Higher Harmonic Surge (Standard Product), WS Series NV-F Type

    Earth Leakage Circuit Breaker Supporting Higher Harmonic Surge (Standard Product), WS Series NV-F Type

    MITSUBISHI

    NV-F type. The series has been expanded from 30A frames to 1600A frames. A new ampere frame is now also available, making it more user-friendly

    Ampere frame AF Rated block capacity AC 100 V(kA) Rated block capacity AC 200 V(kA) Rated block capacity AC 400 V(kA) Number of Poles Rated Operating Voltage(V) Rated Current(A) rate sensitivity current(mA) Mounting Method Representative Standard Dimension height(mm) Dimension width(mm) Dimension depth(mm) Rated block capacity, voltages except VAC 100/200/400, VDC 250 Connection Method
    30AF or less 1.5 1.5 - 3 AC100 to 200 5 30 DIN/Screw retention PSE / CE / TUV / CCC 72 60 73.5 - Surface type
    From: 2,110,000 VND
    Days to Ship: Số ngày giao hàng: Quote
    day to ship Quote
  • You can add up to 6 items per a category to the compare list.

    Earth Leakage Circuit Breaker NV-H Class (High Performance Model) Compatible With High Harmonics And Surges NV63-HV

    Earth Leakage Circuit Breaker NV-H Class (High Performance Model) Compatible With High Harmonics And Surges NV63-HV

    MITSUBISHI

    Ampere frame AF Rated block capacity AC 100 V(kA) Rated block capacity AC 200 V(kA) Rated block capacity AC 400 V(kA) Number of Poles Rated Operating Voltage(V) Rated Current(A) rate sensitivity current(mA) Mounting Method Representative Standard Dimension height(mm) Dimension width(mm) Dimension depth(mm) Rated block capacity, voltages except VAC 100/200/400, VDC 250 Connection Method
    50AF 25 25 10 3 AC100-440 20 ~ 30 30 ~ 100· 200· 500 switch DIN/Screw retention PSE / CE / TUV 130 75 90 Available Surface type
    From: 2,853,750 VND
    Days to Ship: Số ngày giao hàng: Quote
    day to ship Quote
  • You can add up to 6 items per a category to the compare list.

    Earth Leakage Circuit Breaker F Style NV-S Class (General Purpose Model) Compatible With High Harmonics And Surges NV63-SVF

    Earth Leakage Circuit Breaker F Style NV-S Class (General Purpose Model) Compatible With High Harmonics And Surges NV63-SVF

    MITSUBISHI

    Ampere frame AF Rated block capacity AC 100 V(kA) Rated block capacity AC 200 V(kA) Rated block capacity AC 400 V(kA) Number of Poles Rated Operating Voltage(V) Rated Current(A) rate sensitivity current(mA) Mounting Method Representative Standard Dimension height(mm) Dimension width(mm) Dimension depth(mm) Rated block capacity, voltages except VAC 100/200/400, VDC 250 Connection Method
    50AF 15 15 10 3 AC100-440 15 ~ 60 30 ~ 500 DIN/Screw retention PSE / CE / TUV 100 54 90 Available Surface type
    From: 2,828,750 VND
    Days to Ship: Số ngày giao hàng: Quote
    day to ship Quote
  • You can add up to 6 items per a category to the compare list.

    Earth Leakage Circuit Breaker NV-S Class (General Purpose Model) Compatible With High Harmonics And Surges NV125-SVF

    Earth Leakage Circuit Breaker NV-S Class (General Purpose Model) Compatible With High Harmonics And Surges NV125-SVF

    MITSUBISHI

    Ampere frame AF Rated block capacity AC 100 V(kA) Rated block capacity AC 200 V(kA) Rated block capacity AC 400 V(kA) Number of Poles Rated Operating Voltage(V) Rated Current(A) rate sensitivity current(mA) Mounting Method Representative Standard Dimension height(mm) Dimension width(mm) Dimension depth(mm) Rated block capacity, voltages except VAC 100/200/400, VDC 250 Connection Method
    100AF to 199AF 50 50 25 3 AC100-440 100 30 DIN/Screw retention PSE 130 75 90 Available Surface type
    From: 10,940,000 VND
    Days to Ship: Số ngày giao hàng: Quote
    day to ship Quote
BrandNhãn hiệu
Product SeriesDòng sản phẩm
From
Days to ShipSố ngày giao hàng
Ampere frame AF
Rated block capacity AC 100 V(kA)
Rated block capacity AC 200 V(kA)
Rated block capacity AC 400 V(kA)
Number of Poles
Rated Operating Voltage(V)
Rated Current(A)
rate sensitivity current(mA)
Mounting Method
Representative Standard
Dimension height(mm)
Dimension width(mm)
Dimension depth(mm)
Rated block capacity, voltages except VAC 100/200/400, VDC 250
Connection Method

    You can add up to 6 items per a category to the compare list.

    Earth Leakage Circuit Breaker F Style NV-S Class (General-Purpose Product) Harmonic/Surge Compatible Type NV32-SVF

        You can add up to 6 items per a category to the compare list.

        Earth Leakage Circuit Breaker F Style NV-C Class (Economy Product) Harmonic/Surge Compatible Type NV63-CVF

            You can add up to 6 items per a category to the compare list.

            Circuit breaker for control panel FA series (Earth leakage circuit breaker) NV30-FA

                You can add up to 6 items per a category to the compare list.

                Earth Leakage Circuit Breakers (ELCB) NV-SVFU Series

                    You can add up to 6 items per a category to the compare list.

                    Earth Leakage Circuit Breakers (ELCB) NV-CVFU Series

                        You can add up to 6 items per a category to the compare list.

                        Earth Leakage Circuit Breaker Supporting Higher Harmonic Surge (Standard Product), WS Series NV-F Type

                            You can add up to 6 items per a category to the compare list.

                            Earth Leakage Circuit Breaker NV-H Class (High Performance Model) Compatible With High Harmonics And Surges NV63-HV

                                You can add up to 6 items per a category to the compare list.

                                Earth Leakage Circuit Breaker F Style NV-S Class (General Purpose Model) Compatible With High Harmonics And Surges NV63-SVF

                                    You can add up to 6 items per a category to the compare list.

                                    Earth Leakage Circuit Breaker NV-S Class (General Purpose Model) Compatible With High Harmonics And Surges NV125-SVF
                                      BrandNhãn hiệu

                                      MITSUBISHI

                                      MITSUBISHI

                                      MITSUBISHI

                                      MITSUBISHI

                                      MITSUBISHI

                                      MITSUBISHI

                                      MITSUBISHI

                                      MITSUBISHI

                                      MITSUBISHI

                                      Product SeriesDòng sản phẩm

                                      Earth Leakage Circuit Breaker F Style NV-S Class (General-Purpose Product) Harmonic/Surge Compatible Type NV32-SVF

                                      Earth Leakage Circuit Breaker F Style NV-C Class (Economy Product) Harmonic/Surge Compatible Type NV63-CVF

                                      Circuit breaker for control panel FA series (Earth leakage circuit breaker) NV30-FA

                                      Earth Leakage Circuit Breakers (ELCB) NV-SVFU Series

                                      Earth Leakage Circuit Breakers (ELCB) NV-CVFU Series

                                      Earth Leakage Circuit Breaker Supporting Higher Harmonic Surge (Standard Product), WS Series NV-F Type

                                      Earth Leakage Circuit Breaker NV-H Class (High Performance Model) Compatible With High Harmonics And Surges NV63-HV

                                      Earth Leakage Circuit Breaker F Style NV-S Class (General Purpose Model) Compatible With High Harmonics And Surges NV63-SVF

                                      Earth Leakage Circuit Breaker NV-S Class (General Purpose Model) Compatible With High Harmonics And Surges NV125-SVF

                                      From

                                      1,572,500 VND

                                      2,612,500 VND

                                      1,602,500 VND

                                      5,410,000 VND

                                      5,956,250 VND

                                      2,110,000 VND

                                      2,853,750 VND

                                      2,828,750 VND

                                      10,940,000 VND

                                      Days to ShipSố ngày giao hàng Quote Quote Quote Quote Quote Quote Quote Quote Quote
                                      Ampere frame AF30AF or less50AF30AF or less50AF100AF to 199AF30AF or less50AF50AF100AF to 199AF
                                      Rated block capacity AC 100 V(kA)7.57.52.515151.5251550
                                      Rated block capacity AC 200 V(kA)7.57.52.5--1.5251550
                                      Rated block capacity AC 400 V(kA)55-1010-101025
                                      Number of Poles2 / 32 / 322 / 333333
                                      Rated Operating Voltage(V)AC100-440 ~ AC100 to 440AC100-440 ~ AC100 to 440AC100 to 200AC120-240AC120-240AC100 to 200AC100-440AC100-440AC100-440
                                      Rated Current(A)10 ~ 3015 ~ 50155 ~ 5060 ~ 100520 ~ 3015 ~ 60100
                                      rate sensitivity current(mA)30 ~ 50030303030 ~ 100· 200· 500 switch3030 ~ 100· 200· 500 switch30 ~ 50030
                                      Mounting MethodDIN/Screw retentionDIN/Screw retentionDIN/Screw retentionDIN/Screw retentionDIN/Screw retentionDIN/Screw retentionDIN/Screw retentionDIN/Screw retentionDIN/Screw retention
                                      Representative StandardPSE / CE / TUVPSEPSEPSE / CE / TUV / CCCPSE / CE / TUVPSE / CE / TUV / CCCPSE / CE / TUVPSE / CE / TUVPSE
                                      Dimension height(mm)1001007212015072130100130
                                      Dimension width(mm)36 ~ 5436 ~ 544036 ~ 547560755475
                                      Dimension depth(mm)909073.5909073.5909090
                                      Rated block capacity, voltages except VAC 100/200/400, VDC 250Available--AvailableAvailable-AvailableAvailableAvailable
                                      Connection MethodSurface typeSurface typeSurface typeSurface typeSurface typeSurface typeSurface typeSurface typeSurface type

                                      Loading...Tải…

                                      1. 1

                                      Related Categories to Earth Leakage Breakers (Low Capacity)Danh mục liên quan đến Earth Leakage Breakers (Low Capacity)

                                      FAQ Earth Leakage Breakers (Low Capacity)

                                      Question: What is the function and capacity of an Earth Leakage Circuit Breaker (ELCB)?
                                      Answer: An Earth Leakage Circuit Breaker (ELCB) is a crucial safety device in electrical installations. Its primary function is to protect individuals from electric shock by automatically disconnecting the power supply when a fault occurs. ELCBs are designed to detect imbalances in the current flowing between live and neutral conductors. When a leakage current exceeds its rated value (typically 30mA or 100mA), the ELCB trips, interrupting the circuit and preventing potentially fatal injuries. This rapid response time ensures immediate protection against electric shock hazards.
                                      Question: What are the typical reasons for an ELCB to trip, and how does one troubleshoot it?
                                      Answer: ELCB Tripping: Reasons and Troubleshooting
                                      Common Reasons:
                                      1.Earth Leakage: Current flows through unintended path (faulty appliance, wiring, water).
                                      2.Circuit Overload: Current exceeds ELCB's rating (too many appliances).
                                      3.Nuisance Trips: High sensitivity, electrical noise, power surges.
                                      4.Troubleshooting:

                                      Identify affected circuit and appliances.
                                      1.Turn off all appliances and reset ELCB.
                                      2.Switch on appliances one by one to find the culprit.
                                      3.Repair/replace faulty appliance or fix wiring.
                                      4.Test ELCB again with all appliances on.
                                      Question: How does one determine the appropriate tripping capacity and minimum rating for an ELCB?
                                      Answer: 1. Tripping Capacity: This depends on potential fault currents and the maximum allowable leakage. Factors include:
                                      - Fault Current Loop Impedance: The resistance of the path the fault current takes to Earth, influencing how quickly the ELCB trips.
                                      - Maximum Earth Fault Current: The highest current the ELCB should allow to flow before tripping, typically 30mA or 100mA.

                                      2.Minimum Current Rating: This is based on the circuit's maximum current demand and needs to be equal to or higher than the expected circuit load. Factors include:
                                      - Circuit Load: The total current drawn by all appliances connected to the circuit.
                                      - Diversity Factor: Considers that all appliances won't operate at maximum load simultaneously.
                                      Question: What are the standard sizes of earth leakage, and how do you calculate the correct size for your needs?
                                      Answer: Earth leakage circuit breakers (ELCBs) come in a range of standard sizes, typically specified by their rated current (In) and tripping sensitivity (IΔn). Common sizes include:
                                      1.Current (In): 16A, 20A, 25A, 32A, 40A, 63A, 80A, 100A, 125A
                                      2.Sensitivity (IΔn): 30mA, 100mA, 300mA

                                      Choosing the correct size for your needs involves two main considerations:
                                      1.Maximum Current Demand: Calculate the total current drawn by all appliances connected to the circuit.
                                      2.Tripping Sensitivity: Based on safety requirements and potential fault scenarios.

                                      Example: Sum all appliance currents:
                                      Appliance A: 300W (1.3A)
                                      Appliance B: 500W (2.17A)
                                      Total current demand: 3.47A
                                      This means you need an ELCB with a rated current (In) equal to or greater than 3.47A.
                                      Question: How do you measure earth leakage current, and what is the acceptable range for safety standards?
                                      Answer: Measuring earth leakage current requires a specialized instrument called an earth leakage clamp meter. It clamps around the earth conductor of the circuit and measures the current flowing through it. Acceptable levels for safety vary depending on regulations and application:
                                      - IEC 60364-4-42: 30mA maximum for general residential installations.
                                      - BS 7671: 30mA for most domestic circuits, 100mA for specific situations (e.g., bathrooms).