(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Deals with the user needs for the operating monitor functions with a DIN96 × 96 sized large display, and movable pointer.
[Features]
· Ensures good visibility using a DIN96 × 96 size large monitor, and an analog timer with an indicator needle.
· Improved selection ease using multiple power source voltages and time units.
· Alleviates the attachment direction restrictions which were specific to a motor timer.
· Ensures water resistance (IP65).
· Made lighter by combining the motor and electronic circuit.
· UL, CSA certified.
· EN61812-1 types also available. Compatible, corresponds to the CE mark.
H3AM external appearance
H3AM dimensional outline drawing (front), units: mm
Embedded mounting
H3AM dimensional outline drawing (side), units: mm
H3AM dimensional outline drawing (back), units: mm
H3AM mounting hole processing dimensional drawing, units: mm
Note: Mount to panel
Tightening torque: 0.3 N·m ±0.05 N·m
Format | Scale Numbering | Time Units | sec | 10 s | min | 10 m | hrs | 10 h |
---|---|---|---|---|---|---|---|---|
Series H3AM-( )-A | 3 | Time Range Set | - | 0.5 to 30 | 0.05 to 3 | 0.5 to 30 | 0.05 to 3 | 0.5 to 30 |
Series H3AM-( )-B | 6 | - | 1 to 60 | 0.1 to 6 | 1 to 60 | 0.1 to 6 | 1 to 60 | |
Series H3AM-( )-C | 12 | 0.2 to 12 | 2 to 120 | 0.2 to 12 | 2 to 120 | 0.2 to 12 | - |
Note: Instantaneous output by turning the scale in the direction of 0.
Power Supply Voltage | 100 to 240 V AC, 50/60 Hz |
---|---|
Allowable Voltage Variation Range | 85 to 110% of power supply voltage |
Power Supply Reset (Series H3AM-NS) | Minimum power supply open time: 0.5 s |
Reset Application Time (Series H3AM-NSR) | Minimum input signal width: 0.5 s |
Reset Voltage Range (Series H3AM-NSR) | H Level: 85 to 264 V AC L Level: 0 to 10 V AC |
Power Consumption | Approx. 9 VA (Approx. 5 W) |
Control Output | Series H3AM-NS relay (R1), (R2) Series H3AM-NSR relay (R2) (Contact material: AgSnIn) Contact output: 250 V AC, 5 A Resistive load (cosφ = 1) Minimum applied load: 5 V DC, 10 mA (P level, reference) Series H3AM-NSR relay (R1) (Contact material: AgSnIn) Contact output: 250 V AC, 5 A Resistive load (cosφ = 1) Minimum applied load: 5 V DC, 100 mA (P level, reference) |
Operating Temperature Range | -10 to +55°C (No Freezing) |
Ambient Operating Humidity | 35 to 85% |
Storage Temperature Range | -25 to +65°C (No Freezing) |
Variations In Operating Time | ±0.7% (percentage relative to maximum scale) or less | |
---|---|---|
Set Error | ±2% (percentage relative to maximum scale) or less | |
Recovery Time | 0.5 s or less | |
Voltage Effect | ±1% (percentage relative to maximum scale) or less | |
Temperature Effect | ±2% (percentage relative to maximum scale) or less | |
Insulation Resistance | 100 MΩ or more (at 500 V DC megger) | |
Withstand Voltage | 2,000 V AC, 50/60 Hz, 1 min (between the conductive part terminal and exposed non-charging metal part) 2,000 V AC, 50/60 Hz, 1 min (between operation power supply circuit and control output circuit) 1,000 V AC, 50/60 Hz, 1 min (between operation power supply circuit and reset input circuit) (Series H3AM-NSR only) 1,000 V AC, 50/60 Hz, 1 min (between discontinuous contacts) 2,000 V AC, 50/60 Hz, 1 min (between different pole contacts) | |
Impulse Voltage | 5 kV (between power supply terminals), 5 kV (between the conductive part terminal and exposed non-charging metal part) | |
Noise Resistance | Square-wave noise by noise simulator (pulse width 100 ns/1 μs rise 1 ns) ±1.5 kV (between power supply terminals) | |
Electrostatic Strength | 8 kV (Malfunction), 15 kV (Destruction) | |
Vibration | Endurance | 10 to 55 Hz, half amplitude 0.75 mm, 3 directions, 2 cycles each (8 min/cycle) |
Malfunction | 10 to 55 Hz, half amplitude 0.5 mm, 3 directions, 2 cycles each (8 min/cycle) | |
Shock | Endurance | 300 m/s2, 6 directions, 3 times each |
Malfunction | 150 m/s2 (longitudinal direction is 100 m/s2), 6 directions, 3 times each | |
Life | Mechanical | 5 million operations or more (no load, switching frequency 1,800 operations/h) |
Electrical | 100,000 operations or more (250 V AC, 5 A, resistive load, switching frequency 1,800 operations/h) | |
Motor Life | 20,000 Hours | |
Protective Structure | IP65 (Display Only)*, IP20 (Terminal) | |
Mass | Approx. 350 g |
*To secure waterproofing (IP65) between the main body and the panel, waterproof packing Y92S-35 (sold separately) is required.
Part Number |
---|
H3AM-NS-A AC100-240 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng |
---|---|---|---|---|
6,792,730 VND | 1 Piece(s) | Same day |
Loading...Tải…
Type | Timer | Display method | Analog | Mounting Method | Panel |
---|---|---|---|---|---|
Time specifications(s) | 0.5s to 30h | Power Supply Voltage | AC-dedicated | Output Method | Relay |
Dimension vertical(mm) | 96 | Dimension width(mm) | 96 | Dimension depth(mm) | 85 |
Rated power supply voltage(V) | AC 100–240 | Time ranges = N | 5 range | Contact Configuration | Time limit 2c/time limit 1c/instant 1c |
Please check the type/dimensions/specifications of the part H3AM-NS-A AC100-240 in the Analog timer H3AM series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần H3AM-NS-A AC100-240 trong chuỗi Analog timer H3AM.
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy