(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Caution
thận trọng
- 5-Port Solenoid Valve, Plug-in, SY5000/7000 Series, Valve with Residual Pressure Release Valve from SMC.
- SY with residual pressure release valve is used for releasing residual pressure of the 3-position closed center valve. The pressure can be visualized using the red indicator.
- Pressure of 4(A) and 2(B) ports is also exhausted when the pressure of the 1(P) port is exhausted.
- Flow rate is equivalent to that of the normal closed center valve.
* Do not press the indicator as it indicates the pressurization state.
Valve structure | Rubber seal | Metal seal | |
---|---|---|---|
3-position closed center valve with residual pressure exhaust valve^*1) | |||
Operating fluid | Air | ||
Operating pressure range MPa^*2) | 0.3 to 0.7 | 0.3 to 0.7 (High pressure: 0.3-1) | |
Mass g | SY5000 | 117 | 128 |
SY7000 | 156 | 177 |
*1) The residual pressure exhaust valve part is a rubber seal.
*2) Only internal pilot type is available.
*4) When used in combination with a single SUP./EXH. Spacer or spacer type pressure reducing valve, the mounting screw length is different.
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | RoHS | Voltage | Applicable Cylinder Dia. (Ø) | Pressure Rating (MPa) | Seal Type | Coil specifications | Lead wire electrical entry | Manual | Indicator light / Surge voltage suppressor | Piping specifications | Option | Valve specifications | Common specifications | Port pipe connection port diameter (subplate) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | 10 | DC24V | 125 or less | 0.3 to 0.7 | Soft Seal | Standard | - | Push-turn locking hand-operated type | None | - | Standard (0.7 MPa) | - | Non-polarized | - | ||
- | 1 Piece(s) | Quote | - | DC24V | 125 or less | 0.3 to 0.7 | Soft Seal | Standard | - | Non-locking, push type | With surge voltage suppressor | - | Standard (0.7 MPa) | SY5000 | Negative common | - | ||
- | 1 Piece(s) | Quote | - | DC24V | 125 or less | 0.3 to 0.7 | Soft Seal | Standard | - | Non-locking, push type | With light and with surge voltage suppressor | - | Standard (0.7 MPa) | - | Negative common | - | ||
- | 1 Piece(s) | Quote | 10 | DC24V | 125 or less | 0.3 to 0.7 | Soft Seal | Standard | - | Push-turn locking screwdriver-operated type | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | SY5000 | Negative common | - | ||
- | 1 Piece(s) | Quote | - | DC24V | 125 or less | 0.3 to 0.7 | Soft Seal | Standard | - | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | SY5000 | Negative common | - | ||
- | 1 Piece(s) | Quote | 10 | DC24V | 125 or less | 0.3 to 0.7 | Soft Seal | Standard | - | Sliding type locking system | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | SY5000 | Negative common | - | ||
- | 1 Piece(s) | Quote | - | DC24V | 125 or less | 0.3 to 0.7 | Soft Seal | Standard | - | Non-locking, push type | With light and with surge voltage suppressor | - | Standard (0.7 MPa) | - | Non-polarized | - | ||
- | 1 Piece(s) | Quote | - | DC24V | 125 or less | 0.3 to 0.7 | Soft Seal | Standard | - | Push-turn locking screwdriver-operated type | With light and with surge voltage suppressor | - | Standard (0.7 MPa) | - | Non-polarized | - | ||
- | 1 Piece(s) | Quote | 10 | DC24V | 125 or less | 0.3 to 0.7 | Soft Seal | Standard | - | Push-turn locking hand-operated type | With light and with surge voltage suppressor | - | Standard (0.7 MPa) | - | Non-polarized | - | ||
- | 1 Piece(s) | Quote | - | DC24V | 125 or less | 0.3 to 0.7 | Soft Seal | Standard | - | Sliding type locking system | With light and with surge voltage suppressor | - | Standard (0.7 MPa) | - | Non-polarized | - | ||
- | 1 Piece(s) | Quote | - | DC24V | 125 or less | 0.3 to 0.7 | Soft Seal | Standard | - | Non-locking, push type | With light and with surge voltage suppressor | - | Standard (0.7 MPa) | - | Positive common | - | ||
- | 1 Piece(s) | Quote | - | DC12V | 125 or less | 0.3 to 0.7 | Soft Seal | Standard | - | Non-locking, push type | With surge voltage suppressor | - | Standard (0.7 MPa) | SY5000 | Negative common | - | ||
- | 1 Piece(s) | Quote | - | DC12V | 125 or less | 0.3 to 0.7 | Soft Seal | Standard | - | Non-locking, push type | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | SY5000 | Negative common | - | ||
- | 1 Piece(s) | Quote | - | DC12V | 125 or less | 0.3 to 0.7 | Soft Seal | Standard | - | Push-turn locking screwdriver-operated type | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | SY5000 | Non-polarized | - | ||
- | 1 Piece(s) | Quote | - | DC12V | 125 or less | 0.3 to 0.7 | Soft Seal | Standard | - | Non-locking, push type | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | SY5000 | Positive common | - | ||
- | 1 Piece(s) | Quote | - | DC24V | 125 or less | 0.3 to 0.7 | Soft Seal | Standard | - | Non-locking, push type | None | - | Standard (0.7 MPa) | - | Non-polarized | - | ||
- | 1 Piece(s) | Quote | - | DC12V | 125 or less | 0.3 to 0.7 | Soft Seal | Standard | - | Non-locking, push type | None | - | Standard (0.7 MPa) | SY5000 | Non-polarized | - | ||
- | 1 Piece(s) | Quote | 10 | DC24V | 125 or less | 0.3 to 0.7 | Soft Seal | Standard | - | Non-locking, push type | With light and with surge voltage suppressor | - | Quick response (0.7 MPa) | - | Non-polarized | - | ||
- | 1 Piece(s) | Quote | 10 | DC24V | 125 or less | 0.3 to 0.7 | Soft Seal | With energy saving circuit | - | Non-locking, push type | With light and with surge voltage suppressor | - | Standard (0.7 MPa) | - | Negative common | - | ||
- | 1 Piece(s) | Quote | - | DC24V | 125 or less | 0.3 to 0.7 | Soft Seal | With energy saving circuit | - | Non-locking, push type | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | SY5000 | Positive common | - | ||
- | 1 Piece(s) | Quote | 10 | DC24V | 125 or less | 0.3 to 0.7 | Soft Seal | With energy saving circuit | - | Push-turn locking hand-operated type | With light and with surge voltage suppressor | - | Standard (0.7 MPa) | - | Positive common | - | ||
- | 1 Piece(s) | Quote | 10 | DC24V | 125 or less | 0.3 to 0.7 | Soft Seal | With energy saving circuit | - | Sliding type locking system | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | SY5000 | Positive common | - | ||
- | 1 Piece(s) | Quote | - | DC24V | 125 or less | 0.3 to 0.7 | Standard | Standard | - | Non-locking, push type | With surge voltage suppressor | - | Standard (0.7 MPa) | SY5000 | Negative common | - | ||
- | 1 Piece(s) | Quote | - | DC24V | 125 or less | 0.3 to 0.7 | Standard | Standard | - | Non-locking, push type | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | SY5000 | Negative common | - | ||
- | 1 Piece(s) | Quote | - | DC24V | 125 or less | 0.3 to 0.7 | Standard | Standard | - | Non-locking, push type | With light and with surge voltage suppressor | - | Standard (0.7 MPa) | - | Non-polarized | - | ||
- | 1 Piece(s) | Quote | - | DC24V | 125 or less | 0.3 to 0.7 | Standard | Standard | - | Push-turn locking screwdriver-operated type | With light and with surge voltage suppressor | - | Standard (0.7 MPa) | - | Non-polarized | - | ||
- | 1 Piece(s) | Quote | 10 | DC24V | 125 or less | 0.3 to 0.7 | Standard | Standard | - | Sliding type locking system | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | SY5000 | Non-polarized | - | ||
- | 1 Piece(s) | Quote | - | DC24V | 125 or less | 0.3 to 0.7 | Standard | Standard | - | Non-locking, push type | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | SY5000 | Positive common | - | ||
- | 1 Piece(s) | Quote | - | DC12V | 125 or less | 0.3 to 0.7 | Standard | Standard | - | Non-locking, push type | With surge voltage suppressor | - | Standard (0.7 MPa) | SY5000 | Negative common | - | ||
- | 1 Piece(s) | Quote | - | DC12V | 125 or less | 0.3 to 0.7 | Standard | Standard | - | Non-locking, push type | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | SY5000 | Negative common | - | ||
- | 1 Piece(s) | Quote | - | DC12V | 125 or less | 0.3 to 0.7 | Standard | Standard | - | Push-turn locking screwdriver-operated type | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | SY5000 | Non-polarized | - | ||
- | 1 Piece(s) | Quote | - | DC12V | 125 or less | 0.3 to 0.7 | Standard | Standard | - | Non-locking, push type | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | SY5000 | Positive common | - | ||
- | 1 Piece(s) | Quote | - | DC24V | 125 or less | 0.3 to 0.7 | Standard | Standard | - | Non-locking, push type | None | - | Standard (0.7 MPa) | - | Non-polarized | - | ||
- | 1 Piece(s) | Quote | - | DC12V | 125 or less | 0.3 to 0.7 | Standard | Standard | - | Non-locking, push type | None | - | Standard (0.7 MPa) | SY5000 | Non-polarized | - | ||
- | 1 Piece(s) | Quote | 10 | DC24V | 125 or less | 0.3 to 0.7 | Standard | Standard | - | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor | - | Quick response (0.7 MPa) | SY5000 | Non-polarized | - | ||
- | 1 Piece(s) | Quote | 10 | DC24V | 125 or less | 0.3 to 0.7 | Standard | With energy saving circuit | - | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor | - | Quick response (0.7 MPa) | SY5000 | Positive common | - | ||
- | 1 Piece(s) | Quote | 10 | DC24V | 125 or less | 0.3 to 1.0 | Standard | Standard | - | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor | - | High-pressure (1.0 MPa) | SY5000 | Non-polarized | - | ||
- | 1 Piece(s) | Quote | - | DC24V | 125 or less | 0.3 to 0.7 | Standard | With energy saving circuit | - | Sliding type locking system | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | SY5000 | Negative common | - | ||
- | 1 Piece(s) | Quote | 10 | DC24V | 125 or less | 0.3 to 0.7 | Standard | With energy saving circuit | - | Non-locking, push type | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | SY5000 | Positive common | - | ||
- | 1 Piece(s) | Quote | 10 | DC24V | 160 or Less | 0.3 to 0.7 | Soft Seal | Standard | - | Non-locking, push type | With light and with surge voltage suppressor | - | Standard (0.7 MPa) | - | Non-polarized | - | ||
- | 1 Piece(s) | Quote | 10 | DC24V | 160 or Less | 0.3 to 0.7 | Soft Seal | Standard | - | Sliding type locking system | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | SY7000 | Non-polarized | - | ||
- | 1 Piece(s) | Quote | 10 | DC24V | 160 or Less | 0.3 to 0.7 | Soft Seal | Standard | - | Non-locking, push type | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | SY7000 | Positive common | - | ||
- | 1 Piece(s) | Quote | 10 | DC24V | 160 or Less | 0.3 to 0.7 | Standard | Standard | - | Push-turn locking screwdriver-operated type | With indicator light and surge voltage suppressor | - | Standard (0.7 MPa) | SY7000 | Non-polarized | - |
Loading...Tải…
Number of Ports | 5-Port Valve | Application | Manifolds | Switching Type | 3-Position Closed Center |
---|---|---|---|---|---|
Number of Solenoids | Double | Mounting Orientation | Manifold Base | Specifications | Standard |
Status at Power Off | Self-Recovery (Spring Return) | Plumbing | Sub-Base Plumbing | Type | Solenoid Valves |
Driving Type | Pilot Type Spool | Pilot Air Supply | Internal |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy