(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.

  • Viewed
    Products
    Sản phẩm
    đã xem
    최근 본
    상품
    查看产品 查看產品
  • My
    Components
    Linh kiện
    của tôi
    나의 부품 我的部件 我的部件
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • MISUMI Việt Nam đồng hành cùng Kỹ sư tương lai trong cuộc thi SMAE Award 2024. Xem chi tiết.
    MISUMI Vietnam accompanies Future Engineers in the SMAE Award 2024 competition. See more.  

Surface Potential Sensor, IZD10 Series

Surface Potential Sensor, IZD10 Series
You can add up to 6 items per a category to the compare list.

Part Number :
    • From :
      8,866,000VND/Unit
  • Order Qty :
  • Total Price :
    ---
  • Days to ship :
    ---

Select part number to Order Now/ Add to Cart

(i)

Caution

thận trọng

  • Please refer to the manufacturer's catalog for specification details.
  • Product images may be representative images. Refer to the manufacturer's catalog for shape details.

Product Description

Electrostatic sensor that detects the electrostatic potential of a workpiece and outputs in analog voltage.
[Features]
·It is important to check the "actual condition" for static electricity management
·A wide range of charge potential measurements is possible
·Compact size and easy shape to install
·Installation range (IZD10-110): 10 to 50 mm (±0.4 kV when the installation distance is 25 mm)
·Installation range (IZD10-510): 25 to 75 mm (±20 kV when the installation distance is 50 mm)

Electrostatic Sensor, IZD10 Series Specifications

Electrostatic Sensor TypeIZD10-110IZD10-510
Potential Measurement±0.4 kV (detection range at 25 mm)*±20 kV (detection range at 50 mm)*
Output Voltage1 to 5 V (Output impedance: Approx. 100Ω)
Effective Detection Distance10 to 50 mm25 to 75 mm
Linearity±5% F.S. (0 to 50°C, at detection distance of 25 mm)±5%F.S. (0 to 50°C, at detection distance of 50 mm)
Output Delay Time100 ms or less
Power Supply Voltage21.6 to 26.4 V DC (Within 24 V DC ±10%)
Current Consumption40 mA or less
Ambient Operating Temperature0 to 50°C
Ambient Humidity35 to 85% Rh (with no condensation)
MaterialHead case: ABS, Amplifier case: ABS
Vibration ResistanceDurability 50 Hz, Amplitude 1 mm, X, Y, Z: 2 hours each
Impact Resistance100 m/s2
Weight185 g (including cable weight)
Compliance with EN StandardsProtective Class: Class III (EN60950-1)
Pollution Degree 3
CE Marking: Low voltage directive: 2006/95/EC
Only when connected to a SELV-type external circuit
EMC Directive2004/108/EC
UL StandardUL508

*The measured potential and output voltage varies depending on the detection distance. For details of the relationship between measured potentials and output voltages according to detection distance, refer to the "Output Signal" graphs in the Technical Data section of the catalog.

Connection Circuit and Wiring Table

Connect the lead wires according to the connection circuit and wiring table.

IZD10 Series connection circuit

IZD10 Series connection circuit

Lead Wire Coating ColorDescriptionFunction
BrownDC (+)Power supply 24 V DC
BlueDC (-)Power Supply 0 V
WhiteSensor outputAnalog output for 1 to 5 V
  • *Ensure grounding. Ensure GND terminal is grounded with a ground resistance of 100Ω or less. Also, a dedicated power supply is recommended for the sensor-driving power supply. Connecting any equipment other than the sensor to this power supply may trigger the malfunctioning or breakdown of the equipment when static electricity is discharged to the sensor head or when noise enters the GND terminal.
    *When using the cable on the external equipment connection side after cutting it short, do not connect a shielding wire (since the shielding wire is a common wire with the amplifier case, provide a frame ground on the amplifier case side).
  • *Text in ( ) refers to the lead wire coating color of the dedicated cable.

Dimensional Outline Drawing

 

(Unit: mm)

 

IZD10-110/IZD10-510 dimensional drawing 1

IZD10-110/IZD10-510 dimensional drawing 1

 

(Unit: mm)

 

IZD10-110/IZD10-510 dimensional drawing 2

IZD10-110/IZD10-510 dimensional drawing 2

 

(Unit: mm)

 

IZD10-110/IZD10-510 dimensional drawing 3

IZD10-110/IZD10-510 dimensional drawing 3

Output Signal

When measuring the potential of a charged object with an electrostatic sensor, the relationship between the electrostatic potential being measured and the output voltage varies depending on the sensor's installation distance. The relationship between the electrostatic sensor's output voltage and the detected electrostatic potential depending on the installation distance is as shown in the figure below. (The installation distance in the figure refers to the distance between the object being measured and the electrostatic sensor.)

Relationship between Sensor Output Voltage and Electrostatic Potential at Each Installation Distance

IZD10-110 electrostatic potential graph

IZD10-110 electrostatic potential graph

IZD10-510 electrostatic potential graph

IZD10-510 electrostatic potential graph

Detection Range

IZD10 Series detection range

IZD10 Series detection range

IZD10 Series part names

IZD10 Series part names

IZD10-110 (Potential Measurement ±0.4 kV)

Installation Range (mm)Detection Range (mm)
1045
2085
25100
30120
40150
50180

IZD10-510 (Potential Measurement ±20 kV)

Installation Range (mm)Detection Range (mm)
25100
30120
40150
50180
60205
70225
75235

Specific Product Precautions

  • *Product images are representative images. These images may differ from the actual products.
  • *Refer to the catalog for further information.
Part Number
IZD10-110
IZD10-510
Part NumberPriceMinimum Order Qty.Volume DiscountDays to ShipSố ngày giao hàngMeasured potentials

8,866,000 VND

1 Piece(s) 32 Day(s) ±0.4 kV (detection range at 25 mm)

8,866,000 VND

1 Piece(s) 32 Day(s) ±20 kV (detection range at 50 mm)

Loading...Tải…

  1. 1

Basic InformationThông tin cơ bản

Type Antistatic Measurement Devices Indicators Not Provided Additional Function Not Provided
Ion Balance Adjusting Function Not Provided Power Supply DC24V