(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.

  • Viewed
    Products
    Sản phẩm
    đã xem
    최근 본
    상품
    查看产品 查看產品
  • My
    Components
    Linh kiện
    của tôi
    나의 부품 我的部件 我的部件
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • MISUMI Việt Nam đồng hành cùng Kỹ sư tương lai trong cuộc thi SMAE Award 2024. Xem chi tiết.
    MISUMI Vietnam accompanies Future Engineers in the SMAE Award 2024 competition. See more.  

NET Straight/Panel Mountable Connector Harness

NET Straight/Panel Mountable Connector Harness
You can add up to 6 items per a category to the compare list.

Part Number :
  • Order Qty :
  • Price :
    ---
  • Total Price :
    ---
  • Days to ship :
    ---

Select part number to Order Now/ Add to Cart

Connector Acquired Standards
TÜV Standard
DIN VDE0627
UL StandardUL1977
CSA StandardC22.2NO.182.3
● A body ground structure with a high level of safety is used.


· Straight plugs cannot be mated with one another. Use a panel mount receptacle or a cable for relays when setting up a relay.

Wiring and Wire Color Page
>>Click here
Component Page
>>Click here

Product Description

Harness for UL/CSA Standard Supported Connector

Specifications

NET Straight/Panel Mountable Connector Harness:Related Image

Specified Length (m)~ 0.91 ~ 44.1 ~ 50
Tolerance+20mm+50mm+ 3% of Specified Length
* The tolerance of the specified length is as described above.

Connector TypeShape Specification TypeOutline Image Drawing (Unit: mm)ConnectorShell Type
(Shell Size - Number of Cores)
Cable TypeSpecified Length
(m)
NETC

Nanaboshi Electric Mfg.Co,Ltd.






S
(Straight Connector)
NET Straight/Panel Mountable Connector Harness:Related ImageP
Male
(Pin)







S
Female
(Socket)



A1
24-3
(2-core + Ground)


A2
24-4
(3-core + Ground)


A3
28-4
(3-core + Ground)


A4
28-8
(7-core + Ground)


A5
32-3
(2-core + Ground)


A6
32-4
(3-core + Ground)
NET Straight/Panel Mountable Connector Harness:Related Image
0.2

~

50


Can be specified by 0.1m
increments
SY
(Straight Connector
/ Y Terminal)
NET Straight/Panel Mountable Connector Harness:Related Image
ST
(Straight Connector
/ Mark Tube)
NET Straight/Panel Mountable Connector Harness:Related Image
AS
(Relay Connector)
NET Straight/Panel Mountable Connector Harness:Related Image
ASY
(Relay Connector
/ Y Terminal)
NET Straight/Panel Mountable Connector Harness:Related Image
AST
(Relay Connector
/ Mark Tube)
NET Straight/Panel Mountable Connector Harness:Related Image
R
(Panel Mount
Connector)

(Flange Type)
NET Straight/Panel Mountable Connector Harness:Related Image
RY
(Panel Mount
Connector / Y Terminal)

(Flange Type)
NET Straight/Panel Mountable Connector Harness:Related Image


RT
(Panel Mount
Connector / Mark Tube)

(Flange Type)
NET Straight/Panel Mountable Connector Harness:Related Image

More Information

NET Straight/Panel Mountable Connector Harness:Related Image

Electrical Properties
Shell Type
(Shell Size - Number of Cores)
ConnectorA Cable C Cable
Rated Current
(A or less)
Rated Voltage
(V or less)
Section AreaRated VoltageAllowable Current
A (30°C)
Section AreaRated VoltageAllowable Current
A (30°C)
A1 (24-3)202503.5mm2
(AWG12)
600V28AWG12
(3.5 mm2)
600V27
A2 (24-4)152.0mm2
(AWG14)
17AWG14
(2.0 mm2)
18
A3 (28-4)203.5mm2
(AWG12)
25AWG12
(3.5 mm2)
22
A4 (28-8)152.0mm2
(AWG14)
13AWG14
(2.0 mm2)
13
A5 (32-3)305.5mm2
(AWG10)
36AWG10
(5.5 mm2)
35
A6 (32-4)303230
* The values are reference values, not guaranteed values.

NET Straight/Panel Mountable Connector Harness:Related Image
Part Number
NETC-AST-P-A1-C-[0.2-50/0.1]
NETC-AST-P-A1-V-[0.2-50/0.1]
NETC-AST-P-A2-C-[0.2-50/0.1]
NETC-AST-P-A2-V-[0.2-50/0.1]
NETC-AST-P-A3-C-[0.2-50/0.1]
NETC-AST-P-A3-V-[0.2-50/0.1]
NETC-AST-P-A4-C-[0.2-50/0.1]
NETC-AST-P-A4-V-[0.2-50/0.1]
NETC-AST-P-A5-C-[0.2-50/0.1]
NETC-AST-P-A5-V-[0.2-50/0.1]
NETC-AST-P-A6-C-[0.2-50/0.1]
NETC-AST-P-A6-V-[0.2-50/0.1]
NETC-AST-S-A1-C-[0.2-50/0.1]
NETC-AST-S-A1-V-[0.2-50/0.1]
NETC-AST-S-A2-C-[0.2-50/0.1]
NETC-AST-S-A2-V-[0.2-50/0.1]
NETC-AST-S-A3-C-[0.2-50/0.1]
NETC-AST-S-A3-V-[0.2-50/0.1]
NETC-AST-S-A4-C-[0.2-50/0.1]
NETC-AST-S-A4-V-[0.2-50/0.1]
NETC-AST-S-A5-C-[0.2-50/0.1]
NETC-AST-S-A5-V-[0.2-50/0.1]
NETC-AST-S-A6-C-[0.2-50/0.1]
NETC-AST-S-A6-V-[0.2-50/0.1]
Part NumberPriceMinimum Order Qty.Volume DiscountDays to ShipSố ngày giao hàngCN1 CN2 Number Of Cores Shell type Shell size Cable standard (UL/CSA) Cable color Conductor dimensions
(AWG)
Environment resistant Bend tolerant Cable type Specified Length
(M)

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal[3] 3A124UL / CSANavy12Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal[3] 3A124N/AGray12N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal4A224UL / CSANavy14Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal4A224N/AGray14N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal[5] 5A328UL / CSANavy12Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal[5] 5A328N/AGray12N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal8A428UL / CSANavy14Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal8A428N/AGray14N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal[2] 2A532UL / CSANavy10Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal[2] 2A532N/AGray10N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal4A632UL / CSANavy10Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal4A632N/AGray10N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal[3] 3A124UL / CSANavy12Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal[3] 3A124N/AGray12N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal4A224UL / CSANavy14Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal4A224N/AGray14N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal[5] 5A328UL / CSANavy12Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal[5] 5A328N/AGray12N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal8A428UL / CSANavy14Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal8A428N/AGray14N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal[2] 2A532UL / CSANavy10Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal[2] 2A532N/AGray10N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal4A632UL / CSANavy10Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal4A632N/AGray10N/AN/AV0.2 ~ 50

Loading...Tải…

  1. 1

Combination Method


Material / Finish

Item Materials Finish
Main Body (Shell) Zinc Alloy (Shell Size 24)
Aluminum Alloy (Shell Size 28, 32)
Satin Chrome-plated
Insulator Epoxy Resin -
Contact Copper Alloy Silver Plating

Characteristics

Number of Cores Shell
Size
Shape Symbol Contact
Array
Rated Current
(A) or less
Rated Voltage
(V) or less
Withstand Voltage
(VAC)
Insulation Resistance
(MΩ or higher)
Contact Resistance
(MΩ or less)
Applicable Electric Wire Operating Temperature
Range
AWG Section Area (mm2) Finished Outer Diameter (mm)
3 24 PM, PF
ADM,
ADF
RM, RF
20 250 1,500 2,000 3 12 3.5 φ11.5 ~ 14.0 -40°C
~
+100°C
32 PM, PF
ADM,
ADF
RM, RF
30 250 2,000 2,000 3 10 5.5 φ15 ~ 19.5
4 24 PM, PF
ADM,
ADF
RM, RF
15 250 1,500 2,000 3 14 2.0 φ11.5 ~
28 PM, PF
ADM,
ADF
RM, RF
20 250 1,500 2,000 3 12 3.5 φ13.6 ~ 16.5
32 PM, PF
ADM,
ADF
RM, RF
30 250 2,000 2,000 3 10 5.5 φ15 ~ 19.5
8 28 PM, PF
ADM,
ADF
RM, RF
15 250 1,500 2,000 3 14 2.0 φ13.6 ~ 16

(Note) For NET connectors, because the earth contact (terminal with mark) is conductive with the body, do not connect wiring other than an earth wire.

Connection Work Method

Common with the JIS standard medium-sized connector NJC

Wire End Processing Dimensions

Product No. Contact
Shape
A B Conductor Cross-Sectional Area
mm2
AWG Iron Tip Temperature °C Soldering Iron
Wattage (W)
mm mm
NET-24-3- PM, PF
ADM
ADF
RM, RF
20 8.0 3.5 12 370 ~ 400 60
NET-24-4- 21 7.0 2.0 14 350 ~ 370 30
NET-28-4- 20 8.0 3.5 12 370 ~ 400 60
NET-28-8- 21 7.0 2.0 14 350 ~ 370 30
NET-32-3- 35 7.0 5.5 10 370 ~ 400 60 ~ 80
NET-32-4- 35 7.0 5.5 10 370 ~ 400 60 ~ 80

Basic InformationThông tin cơ bản

Connector type NET Connector manufacturer Nanaboshi Electric Mfg. Co., Ltd. Cable rated voltage(V) 600
Cable shape Circular Shield N/A