(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
[Features]· Universal AC input / Full range.· Withstand 300 V AC surge input for 5 seconds.· Built-in active PFC function.· Protections: Short circuit / Overload / Overvoltage / Over temp. (optional for HRP-75 / HRP-100)· Built-in constant current limiting circuit.· Built-in remote sense function (HRP□-150 / 200)· No load power consumption <0.5 W (except for HRP-150/200)· Built-in remote ON/OFF control (except for HRP-150/200)· Built-in 5 V / 0.3 A standby output (HRPG-150/200)· Cooling by free air convection.· 1U low profile.· LED indicator for power on.· 100% full load burn-in test.
Part Number |
---|
RSP-75-24 |
RSP-100-12 |
RSP-100-24 |
RSP-150-24 |
RSP-200-24 |
RSP-320-24 |
RSP-500-24 |
RSP-750-24 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Capacity (W) | Output voltage (Single only) | Rated output current (single only) (A) | Included Function | Representative Standard | Dimension height (mm) | Dimension width (mm) | Dimension depth (mm) | Input Voltage (V) | Rated output current 1 for DC 24 V (A) | Rated output current 2 for DC 12 V (A) | Output voltage variation range (V) | AC Input Voltage Range | AC Input current (Maximum) | DC adjustment range | Output Current Range | Effi. | Overload protection | Over voltage protection | Withstand Voltage | Operating temperature | Safety Standard | EMC standards | Other authentication/standards |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1,577,320 VND | 1 Piece(s) | 7 Day(s) | 75 | DC24V | 3.2 | - | UL / TUV / CCC | 159 | 97 | 30 | - | - | - | - | 85~264VAC; 120~370VDC | Cold start, 35A at 230VAC | -5%~+10% rated output voltage | - | 87.0% | 105%~135% Constant current limiting, auto-recovery | 110%~135% Shut down O/P voltage, re-power on to recover | I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC | -25~+70°C | UL60950-1, TUV EN60950-1, EN61558-1, EN61558-2-16, CCC GB4943 approved; UL62368-1 approved for RSP-150 only | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, GB9254 | - | ||
1,799,324 VND | 1 Piece(s) | 7 Day(s) | 100 | DC12V | 8.5 | - | UL / TUV / CCC | 179 | 99 | 30 | - | - | - | - | 85~264VAC; 120~370VDC | 30A at 230VAC | -5%~+10% rated output voltage | - | 86.0% | 105%~150% Constant current limiting, auto-recovery | 110%~135% Shut down O/P voltage, re-power on to recover | I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC | -30~+70°C (refer to output derating curve) | UL60950-1, TUV EN60950-1, EN61558-1, EN61558-2-16, CCC GB4943 approved; UL62368-1 approved for RSP-150 only | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, GB9254 | - | ||
1,799,324 VND | 1 Piece(s) | 7 Day(s) | 100 | DC24V | 4.2 | - | UL / TUV / CCC | 179 | 99 | 30 | - | - | - | - | 85~264VAC; 120~370VDC | 30A at 230VAC | -5%~+10% rated output voltage | - | 87.0% | 105%~150% Constant current limiting, auto-recovery | 110%~135% Shut down O/P voltage, re-power on to recover | I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC | -30~+70°C (refer to output derating curve) | UL60950-1, TUV EN60950-1, EN61558-1, EN61558-2-16, CCC GB4943 approved; UL62368-1 approved for RSP-150 only | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, GB9254 | - | ||
1,973,157 VND | 1 Piece(s) | 7 Day(s) | 150 | DC24V | 6.3 | - | UL / TUV / CCC | 199 | 99 | 30 | - | - | - | - | 85~264VAC; 120~370VDC | 45A at 230VAC | -5%~+10% rated output voltage | - | 89.0% | 105%~150% Constant current limiting, auto-recovery | 110%~135% Shut down O/P voltage, re-power on to recover | I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC | -30~+70°C (refer to output derating curve) | UL60950-1, TUV EN60950-1, EN61558-1, EN61558-2-16, CCC GB4943 approved; UL62368-1 approved for RSP-150 only | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, GB9254 | - | ||
2,354,978 VND | 1 Piece(s) | 7 Day(s) | 200 | DC24V | 8.4 | - | UL / TUV / CCC | 215 | 115 | 30 | - | - | - | - | 88~264VAC; 124~370VDC | 40A at 230VAC | ±10% rated output voltage | - | 89.5% | 105%~150% Hiccup mode, auto-recovery | 115%~145% Shut down O/P voltage, re-power on to recover | I/P-O/P: 3kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC | -30~+70°C (refer to output derating curve) | UL60950-1, TUV EN60950-1, CCC GB4943 approved | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, GB9254 | - | ||
2,876,479 VND | 1 Piece(s) | 7 Day(s) | 320 | DC24V | 13.4 | - | UL / TUV / CCC | 215 | 115 | 30 | - | - | - | - | 88~264VAC; 124~370VDC | Cold start, 40A at 230VAC | ±10% rated output voltage | - | 89.0% | 105%~135% Hiccup mode, auto-recovery | 115%~145% Shut down O/P voltage, re-power on to recover | I/P-O/P: 3kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC | -30~+70°C (refer to output derating curve) | UL60950-1, TUV EN60950-1 approved; CCC GB4943 approved for RSP-320 only | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(RSP-500/750), GB9254(RSP-320 only) | - | ||
5,158,729 VND | 1 Piece(s) | 7 Day(s) | 500 | DC24V | 21 | - | UL / TUV / CCC | 230 | 127 | 40.5 | - | - | - | - | 85~264VAC; 120~370VDC | Cold start, 40A at 230VAC | ±10% rated output voltage | - | 89.0% | 105%~130% Constant current limiting, auto-recovery | 115%~145% Shut down O/P voltage, re-power on to recover | I/P-O/P: 3kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC | -30~+70°C (refer to output derating curve) | UL60950-1, TUV EN60950-1 approved; CCC GB4943 approved for RSP-320 only | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(RSP-500/750), GB9254(RSP-320 only) | - | ||
8,134,949 VND | 1 Piece(s) | 7 Day(s) | 750 | DC24V | 31.3 | - | UL / TUV / CCC | 250 | 127 | 41 | - | - | - | - | 90~264VAC; 127~370VDC | Cold start, 40A at 230VAC | ±10% rated output voltage | - | 90.5% | 105%~125% Constant current limiting, auto-recovery | 115%~145% Shut down O/P voltage, re-power on to recover | I/P-O/P: 3kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC | -30~+70°C (refer to output derating curve) | UL60950-1, TUV EN60950-1 approved; CCC GB4943 approved for RSP-320 only | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(RSP-500/750), GB9254(RSP-320 only) | - |
Loading...Tải…
Shape | With Cover | Single/multi | Single | Input Voltage | AC/DC |
---|---|---|---|---|---|
Input/output terminal shape | Screw |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy