(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Ideal DIN rail mounting type for a system that connects a touch panel / PLC and a temperature controller while maintaining the operability and high performance of the E5□C type series.
Added push-in Plus terminal block type lineup.
[Features]
・ A slim body that fits in a low profile control panel with a DIN rail mounting type with a depth of 85 mm and a width of 22.5 mm
・ Easy-to-replace terminal block attachment/detachment structure improves maintainability
・ In addition to the screw terminal block type, you can select from the push-in Plus terminal block type that reduces wiring man-hours
・ Push-in Plus terminal block type is a connector and does not require wiring of power supply / communication line (Maximum number of connected units: 16)
・ High-speed sampling 50 ms makes it suitable for high-speed heating apps
・ Easy connection with PLC by programless communication
·By using a communication conversion cable (sold separately) to connect to a computer, settings can be configured without power wiring. Easy to set up from CX-Thermo (sold separately)
・ Enhanced basic functions of auxiliary output (2 points maximum) and event input (1 point maximum)
・ Easy-to-read white PV display that makes it easy to check when starting up or when something is wrong even inside the panel (PV height: 8.5 mm)
Part Number |
---|
E5DC-RX0ASM-015 |
E5DC-RX0DSM-015 |
E5DC-RX2ASM-002 |
E5DC-RX2ASM-017 |
E5DC-RX2DSM-000 |
E5DC-RX2DSM-002 |
E5DC-RX2DSM-017 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Output Type | Failure Detecting Function | Power Supply Voltage (V) | Control Output 1 | Auxiliary output points | Event Input (Point) | Heater Breakage, SSR Fault Detection Capability |
---|---|---|---|---|---|---|---|---|---|---|---|
6,133,700 VND | 1 Piece(s) | 6 Day(s) or more | Relay contact | - | 100 to 240 VAC | Relay Output | None | None | - | ||
6,133,700 VND | 1 Piece(s) | 6 Day(s) or more | Relay contact | - | 24 VAC/DC | Relay Output | None | None | - | ||
8,201,860 VND | 1 Piece(s) | 6 Day(s) or more | Relay contact | Heater Breakage / SSR Breakdown | 100 to 240 VAC | Relay Output | 2 (one common) | None | 1 | ||
5,832,100 VND | 1 Piece(s) | 24 Day(s) or more | Relay contact | Heater Breakage / SSR Breakdown | 100 to 240 VAC | Relay Output | 2 (one common) | 1 | 1 | ||
5,385,603 VND | 1 Piece(s) | 6 Day(s) or more | Relay contact | - | 24 VAC/DC | Relay Output | 2 (one common) | None | - | ||
8,395,146 VND | 1 Piece(s) | 21 Day(s) or more | Relay contact | Heater Breakage / SSR Breakdown | 24 VAC/DC | Relay Output | 2 (one common) | None | 1 | ||
5,832,100 VND | 1 Piece(s) | 85 Day(s) or more | Relay contact | Heater Breakage / SSR Breakdown | 24 VAC/DC | Relay Output | 2 (one common) | 1 | 1 |
Loading...Tải…
Number of Control Points | 1 | Number of Input Points(pcs.) | 1 | Acquired Standards | UL / CSA / CE |
---|---|---|---|---|---|
Type | Temperature Controller / Controller | Control Output 2 | No |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy