(!)Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site.Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
[Thông báo] Cập nhật địa chỉ kho tập kết hàng hóa tại khu vực miền Nam của MISUMI Việt Nam. Xem chi tiết.
[Announcement] Update on warehouse address in the Southern region of MISUIMI Vietnam. See more.
[Cảnh Báo] Thủ Đoạn Lừa Đảo Từ Nhân Viên Giao Hàng – Yêu Cầu Trả Phí Ship. Xem chi tiết.
[Warning] Fraud Calling from Shipper - Asking to Pay Shipping Fee. See more.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement. Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Terminal Relays and Thermal Overload Relays products from the electrical and controls category. When selecting, it is essential to consider factors such as Size, Mounting Method, Number of Poles, Load Current, Safety standards and so on. These considerations are crucial for ensuring the production of high-quality products. We highly recommend reputable brands MISUMI, ABB and FUJI ELECTRIC Take advantage of the convenience of FREE SHIPPING and NO MINIMUM ORDER on Terminal Relays, Thermal Overload Relays and other related products. If you have any doubts or require assistance in choosing the right product, our experts are readily available to provide advice and guidance.
[Features]· Small 4-point terminal relay.· 5A power switching type that is small, highly sensitive, and highly durable with 4 G6B mini relays.· Main body of the relay is made with plastic seal structure.· Wiring is easy with terminals divided into IN/OUT structure.· Includes operation display LED.· Built-in surge absorbing diode.· S.· Dedicated socket for easy replacement (excluding high reliability).· Standardized with UL, CSA authorized standard parts (excluding high reliability).· Models G6B-4BND/47BND/48BND/DC12/24V are VDE authorized standard parts.· DIN rail mounting, screw mounting types also available.
From:
898,800 VND
Special Price
Days to Ship: Số ngày giao hàng:
Same day
Same day
You can add up to 6 items per a category to the compare list.
[Features]· Small mount space vertical style terminal relay with 4-point output.· Width 28 mm × height 90 mm × depth 45 mm space saving size.· Selection of model G6D relay equipped type and G3DZ non-contact type power MOS FET relay equipped type.· Terminal has IN/OUT isolated construction, so wiring is simple.· Operation display LED included.· Built-in surge-absorbing diode.· Dedicated socket allows for easy relay replacement.· Common use DIN rail mounting, screw mounting.· Includes relay removal tool.
From:
1,182,000 VND
Special Price
Days to Ship: Số ngày giao hàng:
Same day
Same day
BrandNhãn hiệu
Product SeriesDòng sản phẩm
From
Days to ShipSố ngày giao hàng
You can add up to 6 items per a category to the compare list.
You can add up to 6 items per a category to the compare list.
Question: How can you determine the terminals on a relay?
Answer: 1. Datasheet Review: Examine the relay's datasheet for a diagram or labeled information. It typically includes designations like "Coil," "NO" (Normally Open), "NC" (Normally Closed), and possibly coil polarity markings like "A1" and "A2."
2. Visual Inspection: Examine the relay's case for symbols or markings indicating terminal functions. Sometimes, terminals are labeled directly on the relay.
Question: How does a 4-terminal relay differ from a 5-terminal relay?
Answer: The primary difference between a 4-pin relay and a 5-pin relay lies in their ability to control multiple circuits.
A 4-pin relay is designed to control a single circuit. It has two pins for controlling the relay coil (85 and 86) and two pins for switching power on or off (30 and 87). The 30 pin is the source of power, and the 87 pin is the load to be controlled.
A 5-pin relay is designed to control two independent circuits. It has two pins for controlling the relay coil (85 and 86) and three pins for switching power on or off (30, 87a, and 87). The 30 pin is the source of power, the 87a pin serves as the normally open (NO) contact, and the 87 pin serves as the normally closed (NC) contact. This allows for switching between two separate circuits.
Question: What is the main part of a relay?
Answer:
The main components of a relay are two:
1. The coil is the primary component of a relay. It is responsible for creating the magnetic field that attracts the contact.
2. Contact: It is a pair of metal pieces that are separated by a small gap. When the coil is energized, the magnetic field attracts the contact together, closing the gap. It works like a switch to control the direction of current flow to the desired device.
Question: What are the different types of relay terminals?
Answer: Relays commonly have various terminals serving distinct purposes for example:
• NC terminal, which stands for 'Normal Closed,' means that the contact is normally closed. This means that the contact is connected to the C terminal even if the coil is not energized. We generally connect this terminal to devices or appliances that need to be powered on at all times.
• NO terminal, which stands for 'Normal Open,' means that the contact is normally open. This means that the contact is not connected to the C terminal even if the coil is not energized. We generally connect this terminal to devices or appliances that need to be powered on for a limited period of time only.
• C terminal, which stands for 'common,' is the common point that is connected to the power source.
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy