    Product CodeDevice short nameFixing modeElectrical durabilityMechanical durability Width Height Depth IP degree of protectionStandardsAmbient air temperature for operationAmbient air temperature for storageProduct certificationsSustainable offer statusEU RoHS DirectiveMercury freeRoHS exemption informationChina RoHS RegulationEnvironmental DisclosureWEEEOperating altitudeREACh RegulationWarrantyMotor power kWUtilisation categoryNetwork frequencyTightening torqueOperating positionRange[Ue] rated operational voltage[Ui] rated insulation voltage[Ith] conventional free air thermal currentIK degree of protectionConnections - terminalsPoles descriptionMaximum operating rate[Uimp] rated impulse withstand voltageProtective treatmentProduct nameBreaking capacityDevice applicationControl typePower dissipation per poleFire resistancePhase failure sensitivityNetwork typeThermal protection adjustment range[In] rated current[Ics] rated service short-circuit breaking capacityTrip unit technologyMagnetic tripping currentRated dutySuitability for isolation
    GV2P32GV2P35 mm symmetrical DIN rail: clipped
    Panel: screwed (with 2 x M4 screws)
    100000 cycles 
    for AC-3 at 440 V
    100000 cycles45 mm89 mm97 mmIP20 conforming to IEC 60529EN/IEC 
    60947-2
    EN/IEC 
    60947-4-1
    UL 60947-4-1
    CSA C22.2 No 
    60947-4-1
    -20 to 60 °C-40 to 80 °CIECEE CB Scheme
    UL
    CSA
    CCC
    EAC
    ATEX
    BV
    LROS (Lloyds register of shipping)
    DNV-GL
    RINA
    Green Premium productCompliant  EU RoHS DeclarationYesYesChina RoHS declarationProduct Environmental ProfileThe product must be disposed on European Union markets following specific 
    waste collection and never end up in rubbish bins
    2000 mREACh Declaration18 months15 kW 
    at 400/415 V AC 
    50/60 Hz
    18.5 kW 
    at 500 V AC 
    50/60 Hz
    22 kW 
    at 690 V AC 
    50/60 Hz
    AC-3 conforming to IEC 
    60947-4-1
    Category A conforming to IEC 
    60947-2
    50/60 Hz conforming to IEC 
    60947-4-1
    1.7 N.m 
    on screw clamp terminals
    Any positionTeSys690 V AC 50/60 Hz conforming to IEC 
    60947-2
    690 V AC 50/60 Hz 
    conforming to IEC 60947-2
    32 A conforming to IEC 60947-4-1IK04Screw clamp terminals 2 cable(s) 
    1 to 6 mm2 solid
    Screw clamp terminals 2 cable(s) 
    1.5 to 6 mm2 
    flexible without cable end
    Screw clamp terminals 2 cable(s) 
    1 to 4 mm2 flexible with cable end
    3P25 cyc/hIEC 60947-2 6 kVTHTeSys GV2100 kA Icu 
    at 230/240 V AC 50/60 Hz 
    conforming to IEC
    60947-2
    10 kA Icu 
    at 500 V AC 50/60 Hz 
    conforming to IEC
    60947-2
    4 kA Icu 
    at 690 V AC 50/60 Hz 
    conforming to IEC
    60947-2
    20 kA Icu 
    at 440 V AC 50/60 Hz 
    conforming to IEC
    60947-2
    50 kA Icu 
    at 400/415 V AC 50/60 Hz 
    conforming to IEC
    60947-2
    MotorRotary knob2.5 W960 °C conforming to IEC 
    60695-2-1
    Yes conforming to IEC 
    60947-4-1
    AC24 to 32 A32 A100 % 
    at 690 V AC 50/60 Hz 
    conforming to IEC 
    60947-2
    100 % 
    at 230/240 V AC 50/60 Hz 
    conforming to IEC 
    60947-2
    75 % 
    at 500 V AC 50/60 Hz 
    conforming to IEC 
    60947-2
    50 % 
    at 400/415 V AC 50/60 Hz 
    conforming to IEC 
    60947-2
    75 % 
    at 440 V AC 50/60 Hz 
    conforming to IEC 
    60947-2
    Thermal-magnetic416 AContinuous conforming to IEC 
    60947-4-1
    Yes conforming to IEC 