(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Caution
thận trọng
- I/O module, iQ-R series from MITSUBISHI.
- Input/output rating is printed at the front, reducing incorrect wiring.
- Easy-to-use cable tie hook for tidy wiring.
- Existing 16-point terminal blocks are reusable, eliminating rewiring.
- Simple confirmation by product serial no. printed on the front.
- Alternating toggle switch used to display between 32-point LED signals.
- Terminal signals are clearly labeled and color-coded.
- Up to 32 LED signals clearly visible.
External appearance of RX40C7
RX40C7 dimensional drawing (unit: mm)
External appearance of RX10
Dimensional drawing of RX10 (Unit: mm)
Items | AV Input | DC input | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
RX28 | RX10 | RX10-TS | RX40C7 | RX40C7-TS | RX41C4 | RX41C4-TS | RX42C4 | RX70C4 | RX71C4 | RX72C4 | |
Number Of Points [Points] | 8 | 16 | 16 | 16 | 16 | 32 | 32 | 64 | 16 | 32 | 64 |
Rated Input Voltage, Frequency [V] | 100 to 240 V AC (50/60 Hz) | 100 to 240 V AC (50/60 Hz) | 100 to 240 V AC (50/60 Hz) | DC24 | DC24 | DC24 | DC24 | DC24 | DC5/12 | DC5/12 | DC5/12 |
Rated Input Current [mA] | 16.4 (200 V AC, 60 Hz) 13.7 (200 V AC, 50 Hz) 8.2 (100 V AC, 60 Hz) 6.8 (100 V AC, 50 Hz) | 8.2 (100 V AC, 60 Hz) 6.8 (100 V AC, 50 Hz) | 8.2 (100 V AC, 60 Hz) 6.8 (100 V AC, 50 Hz) | 7.0 TYP. | 7.0 TYP. | 4.0 TYP. | 4.0 TYP. | 4.0 TYP. | 1.7 (5 V DC) 4.8 (12 V DC) | 1.7 (5 V DC) 4.8 (12 V DC) | 1.7 (5 V DC) 4.8 (12 V DC) |
Response time | 20 ms or less | 20 ms or less | 20 ms or less | 0.1 to 70 ms | 0.1 to 70 ms | 0.1 to 70 ms | 0.1 to 70 ms | 0.1 to 70 ms | 0.1 to 70 ms | 0.1 to 70 ms | 0.1 to 70 ms |
Common Method [Point/Common] | 8 | 16 | 16 | 16 | 16 | 32 | 32 | 32 | 16 | 32 | 32 |
Interrupt Function | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
External wiring connection method^*1 | |||||||||||
18-Point Screw Terminal Block | ● | ● | — | ● | — | — | — | — | ● | — | — |
40-pin connector | — | — | — | — | — | ● | — | ● (× 2) | — | ● | ● (× 2) |
Items | DC High-Speed Input | Input With Self-Diagnosis Function | |||
---|---|---|---|---|---|
RX40PC6H | RX40NC6H | RX41C6HS | RX61C6HS | RX40NC6B | |
Number Of Points [Points] | 16 | 16 | 32 | 32 | 16 |
Rated Input Voltage, Frequency [V] | DC24 | DC24 | DC24 | DC5 | DC24 |
Rated Input Current [mA] | 6.0 | 6.0 | 6.0 | 6.0 | 6.0 |
Response time | 5 μs to 70 ms | 5 μs to 70 ms | 1 μs to 70 ms | 1 μs to 70 ms | 1 ms to 70 ms |
Common Method [Point/Common] | 8 (Positive common) | 8 (Negative common) | 32 (Positive/negative common) | 32 (Positive/negative common) | 16 (Negative common) |
Interrupt Function | ● | ● | ● | ● | ● |
Self-Diagnosis Function | |||||
Disconnection Detection Function | — | — | — | — | ● |
External wiring connection method^*1 | |||||
18-Point Screw Terminal Block | ● | ● | — | — | ● |
40-pin connector | — | — | ● | ● | — |
External appearance of RY20S6
Dimensional drawing of RY20S6 (Unit: mm)
External appearance of RY41PT2H
Dimensional drawing of RY41PT2H (Unit: mm)
Items | Relay output | Triac output | Transistor (Sink) Output | |||||||
---|---|---|---|---|---|---|---|---|---|---|
RY18R2A | RY10R2 | RY10R2-TS | RY20S6 | RY40NT5P | RY40NT5P-TS | RY41NT2P | RY41NT2P-TS | RY42NT2P | RY41NT2H | |
Number Of Points [Points] | 8 | 16 | 16 | 16 | 16 | 16 | 32 | 32 | 64 | 32 |
Rated Switch Voltage/Current | 24 V DC/2 A 240 V AC/2 A | 24 V DC/2 A 240 V AC/2 A | 24 V DC/2 A 240 V AC/2 A | AC100 to 240 V/0.6 A | — | — | — | — | — | — |
Rated Load Voltage [V] | — | — | — | — | DC12 to 24 | DC12 to 24 | DC12 to 24 | DC12 to 24 | DC12 to 24 | DC5 to 24 |
Maximum Load Current [A/Point] | — | — | — | — | 0.5 | 0.5 | 0.2 | 0.2 | 0.2 | 0.2 |
Response time | 12 ms or less | 12 ms or less | 12 ms or less | 1 ms + 0.5 cycle or less | 1 ms or less | 1 ms or less | 1 ms or less | 1 ms or less | 1 ms or less | 2 μs or less |
Common Method [Point/Common] | — | 16 | 16 | 16 | 16 | 16 | 32 | 32 | 32 | 32 |
Protection Function (Overload/Overheat) | — | — | — | — | ● | ● | ● | ● | ● | — |
External wiring connection method^*1 | ||||||||||
18-Point Screw Terminal Block | ● | ● | — | ● | ● | — | — | — | — | — |
40-pin connector | — | — | — | — | — | — | ● | — | ● (× 2) | ● |
Items | Transistor (Source) Output | Output With Self-Diagnosis Function (Source) | |||||
---|---|---|---|---|---|---|---|
RY40PT5P | RY40PT5P-TS | RY41PT1P | RY41PT1P-TS | RY42PT1P | RY41PT2H | RY40PT5B | |
Number Of Points [Points] | 16 | 16 | 32 | 32 | 64 | 32 | 16 |
Rated Load Voltage [V] | DC12 to 24 | DC12 to 24 | DC12 to 24 | DC12 to 24 | DC12 to 24 | DC5 to 24 | 24 V DC |
Maximum Load Current [A/Point] | 0.5 | 0.5 | 0.1 | 0.1 | 0.1 | 0.2 | 0.5 |
Response time | 1 ms or less | 1 ms or less | 1 ms or less | 1 ms or less | 1 ms or less | 2 μs or less | 1.5 ms or less |
Common Method [Point/Common] | 16 | 16 | 32 | 32 | 32 | 32 | 16 |
Protection Function (Overload/Overheat) | ● | ● | ● | ● | ● | — | ● |
Self-Diagnosis Function | |||||||
Output Disconnection Detection Function | — | — | — | — | — | — | ● |
Output Short-Circuit Detection Function | — | — | — | — | — | — | ● |
External wiring connection method^*1 | |||||||
18-Point Screw Terminal Block | ● | — | — | — | — | — | ● |
40-pin connector | — | — | ● | — | ● (× 2) | ● | — |
External appearance of RH42C4NT2P
Dimensional drawing of RH42C4NT2P (Unit: mm)
Items | RH42C4NT2P |
---|---|
DC input | |
Number Of Points [Points] | 32 |
Rated Input Voltage [V] | DC24 |
Rated Input Current [mA] | 4.0 TYP. |
Response time | 0.1 to 70 ms |
Common Method [Point/Common] | 32 |
Interrupt Function | ● |
Transistor (Sink) Output | |
Number Of Points [Points] | 32 |
Rated Load Voltage [V] | DC12 to 24 |
Maximum Load Current [A/Point] | 0.2 |
Response time | 1 ms or less |
Common Method [Point/Common] | 32 |
Protection Function (Overload/Overheat) | ● |
External wiring connection method^*1 | |
40-pin connector | ● (× 2) |
* External appearances and dimensional drawings provided here do not cover all models.
Part Number |
---|
RY40NT5P-TS |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Number Of Inputs | Input Format | Rated Input Voltage (V) | Input answer time | Number of Outputs | Output Format | Rated load voltage (V) | Protection function | Connection Terminal | Representative Standard | Features | Output answer time | Terminal shape | Occupied I/O Points on PLC | Wiring | Int. Current Consumption (A) | Input Response Time Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2,482,500 VND | 1 Piece(s) | 98 Day(s) | - | - | - | - | 16 | Transistor / sync output | DC12 to 24 | Output protection function | Europe terminal block | CE / UL / CUL | - | 1 ms or less | Spring clamp terminal block | - | - | - | - |
Loading...Tải…
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy