MELSEC Series Special Adapter for Communication

:
MITSUBISHI

    MELSEC Series Special Adapter for Communication
    The MELSEC Series Special Adapter for Communication is an essential component designed to enhance communication capabilities within the MELSEC PLC systems
    [Feature]
    • Communication Type : RS-232 and RS-422/485
    • Easy Integration: Designed for compatibility with MELSEC FX3U and FX5 series PLCs
    • MODBUS Compatibility: Functions as a MODBUS communication master or slave, making it suitable for diverse applications in industrial environments
    [Application]
    These adapters enable seamless integration with various MODBUS communication devices

    MELSEC Special Adapter for Communication Specifications

    RS-232C Special Adapter for Communication (MODBUS compatible)

    Overview: RS-232C communication (MODBUS compatible)
    Compliant standards: CE (EMC), UL/cUL, KC, ABS, DNV, GL, LR, BV, RINA, NK, KR
    When connected to an FX3 series unit, this adapter lets it function as a MODBUS communication master station or slave station to connect to various MODBUS communication device.
    It can also be used as a nonprocedural communication, computer link or programming communication device.

    MELSEC-F RS-232C Special Adapter for Communication: related image

    FX3U-232ADP-MB external appearance

    MELSEC-F RS-232C Special Adapter for Communication: related image

    FX3U-232ADP-MB drawing
    Unit: mm

    RS-485 Special Adapter for Communication (MODBUS compatible)

    Overview: RS-485 communication (MODBUS compatible)
    Compliant standards: CE (EMC), UL/cUL, KC, ABS, DNV, GL, LR, BV, RINA, NK, KR
    When connected to an FX3 series unit, this adapter lets it function as a MODBUS communication master station or slave station to connect to various MODBUS communication device.
    It can also be used as a nonprocedural communication, computer link, parallel link, simple PC-PC link or inverter communication device.

    MELSEC-F RS-232C Special Adapter for Communication: related image

    FX3U-485ADP-MB external appearance

    MELSEC-F RS-232C Special Adapter for Communication: related image

    FX3U-485ADP-MB drawing
    Unit: mm

    RS-232C Communication Expansion Adapter

    Overview: D-Sub 9-pin type, RS-232C communication
    Compliant standards: CE (EMC), UL/cUL, KC, ABS, DNV, GL, LR, BV, RINA, NK, KR
    RS-232C communication expansion adapter with D-sub 9-pin connector.
    Insulated signal exchange unit that communicates serial data with RS-232C devices via the RS232C protocol.

    MELSEC-F RS-232C Special Adapter for Communication: related image

    FX5-232ADP external appearance

    MELSEC-F RS-232C Special Adapter for Communication: related image

    FX5-232ADP drawing
    Unit: mm

    RS-485 Communication Expansion Adapter

    Overview: European terminal block type, RS-485 communication
    Compliant standards: CE (EMC), UL/cUL, KC, ABS, DNV, GL, LR, BV, RINA, NK, KR
    RS-485 communication expansion adapter having a European terminal block.
    Insulated signal exchange unit for connecting devices having an RS-485 interface.

    MELSEC-F RS-232C Special Adapter for Communication: related image

    FX5-485ADP external appearance

    MELSEC-F RS-232C Special Adapter for Communication: related image

    FX5-485ADP drawing
    Unit: mm

    Process CPU unit R16PCPU

    Overview:
    Number of input/output points: 4,096 points
    Program Capacity: 160 K steps
    Basic command processing time (LDX0): 0.98 ns
    Program memory capacity: 640 K bytes
    Peripheral connection port: USB, Ethernet
    Compliant standards: UL/cUL, CE (EMC), KC

    MELSEC-F RS-232C Special Adapter for Communication: related image

    R16PCPU external appearance

    MELSEC-F RS-232C Special Adapter for Communication: related image

    R16PCPU drawing
    Unit: mm

    MELSEC-F Performance Specifications

    FX3U-232ADP-MB

    Transmission StandardsRS-232C compliant
    Insulation MethodOpto-isolator insulation
    Transmitting DistanceMaximum 15 m
    External Device Connection MethodD-SUB 9-pin connector (male)
    Communication MethodBi-directional full-duplex
    Communication Procedure· MODBUS communication (master or slave)
    · Nonprocedural communication
    · Computer link (dedicated protocol type 1, dedicated protocol type 4)
    · Programming communication
    Communication SpeedMODBUS Communication300/600/1,200/2,400/4,800/9,600/19,200/38,400/57,600/115,200 (bps)
    38,400/57,600/115,200 bps are supported by products manufactured in or after July 2012. (Serial number: 127**** or later)
    Nonprocedural Communication, Computer Link300/600/1,200/2,400/4,800/9,600/19,200/38,400 (bps)
    The FX3U and FX3UC Series support 38,400 bps effective from Ver. 2.41.
    Programming Communication9,600/19,200/38,400/57,600/115,200 (bps)
    Display (LED)RD, SD, POWER
    Number of Occupied Inputs/Outputs0 point (This has nothing to do with the maximum number of input/output points of the sequencer)
    Applicable Sequencers[FX3S]
    V1.00 or later: All communication functions are supported
    [FX3G]
    V1.00 or later: Communication functions other than MODBUS communication are supported
    V1.30 or later: MODBUS communication function is supported
    [FX3U]
    V2.20 or later: Communication functions other than MODBUS communication are supported
    V2.40 or later: MODBUS communication function is supported
    [FX3GC]
    V1.40 or later: All communication functions are supported
    [FX3UC]
    V1.00 or later: Communication functions other than MODBUS communication are supported
    V2.40 or later: MODBUS communication function is supported
    The FX3S-CNV-ADP is needed to connect to an FX3S.
    FX3G-CNV-ADP is required to connect to the FX3G.
    A function expansion board is required to connect to an FX3U or FX3UC-32MT-LT (-2).
    Weight0.08 kg
    Power Supply Specifications
    Power Supply5 V DC, 30 mA (internal power supply from sequencer)

    FX3U-485ADP-MB

    Transmission StandardsCompliant with the RS-485 standard and RS-422 standard
    Insulation MethodOpto-isolator insulation
    Transmitting DistanceTotal extension length 500 m or less
    (If the device to be connected includes FX2N-485-BD, FX1N-485-BD, FX3U-485-BD or FX3G-485-BD, the total extension length is 50 ms or less)
    External Device Connection MethodEuropean Terminal Block
    Communication MethodBidirectional half-duplex
    Communication Procedure· MODBUS (master or slave)
    · Nonprocedural communication
    · Computer link (dedicated protocol type 1, dedicated protocol type 4)
    · Parallel link
    · Simple PC-PC link
    · Inverter communication
    Communication SpeedMODBUS Communication300/600/1,200/2,400/4,800/9,600/19,200/38,400/57,600/115,200 (bps)
    38,400/57,600/115,200 bps are supported by products manufactured in or after July 2012. (Serial number: 127**** or later)
    Nonprocedural, Computer Link300/600/1,200/2,400/4,800/9,600/19,200/38,400 (bps)
    The FX3U and FX3UC Series support 38,400 bps effective from Ver. 2.41.
    Parallel Link115,200 (bps)
    Simple PC to PC Link38,400 (bps)
    Inverter Communication4,800/9,600/19,200/38,400 (bps)
    The FX3U and FX3UC Series support 38,400 bps effective from Ver. 2.41.
    Display (LED)RD, SD, POWER
    Number of Occupied Inputs/Outputs0 point (This has nothing to do with the maximum number of input/output points of the sequencer)
    Applicable Sequencers[FX3S]
    V1.00 or later: All communication functions are supported
    [FX3G]
    V1.00 or later: Communication functions other than MODBUS and inverter communications are supported
    V1.10 or later: Inverter communication function is supported
    V1.30 or later: MODBUS communication function is supported
    [FX3U]
    V2.20 or later: Communication functions other than MODBUS communication are supported
    V2.40 or later: MODBUS communication function is supported
    [FX3GC]
    V1.40 or later: All communication functions are supported
    [FX3UC]
    V1.00 or later: Communication functions other than MODBUS communication are supported
    V2.40 or later: MODBUS communication function is supported
    FX3S-CNV-ADP is needed to connect to FX3S.
    FX3G-CNV-ADP is required to connect to the FX3G.
    A function expansion board is required to connect to an FX3U or FX3UC-32MT-LT (-2).
    Weight0.08 kg
    Power Supply Specifications
    Power Supply5 V DC, 20 mA (internal power supply from sequencer)

    FX5-232ADP

    Transmission StandardsRS-232C standard-compliant
    External Device Connection MethodD-sub 9-pin (male)
    InsulationOpto-isolator insulation (between the communication line and the CPU)
    Communication FunctionMC Protocol FunctionMaximum Total Extension Distance15 m or less
    Protocol FormatMC protocol (dedicated protocol), 3C/4C frame
    Type 1 / type 4 / type 5 are available.
    Communication MethodBidirectional half-duplex
    Baud Rate300/600/1,200/2,400/4,800/9,600/19,200/38,400/57,600/115,200 (bps)
    Nonprocedural Communication FunctionMaximum Total Extension Distance15 m or less
    Control ProcedureNonprocedural Communication
    Communication MethodBidirectional half-duplex / Bidirectional full-duplex
    Baud Rate300/600/1,200/2,400/4,800/9,600/19,200/38,400/57,600/115,200 (bps)
    Communication Protocol Support FunctionMaximum Total Extension Distance15 m or less
    Protocol FormatCommunication Protocol Support
    Communication MethodBidirectional half-duplex
    Baud Rate9,600/19,200/38,400/57,600/115,200 (bps)
    MODBUS Communication FunctionTransmitting Distance15 m or less
    Communication ProtocolRTU
    Baud Rate300/600/1,200/2,400/4,800/9,600/19,200/38,400/57,600/115,200 (bps)
    Compatible CPU UnitsFX5U CPU unit: Ver. 1.000 onward (from the first unit)
    FX5UC CPU unit: Ver. 1.010 onward (from the first unit)
    WeightApprox. 80 g
    Power Supply Specifications
    Rated Voltage (Internal Power Supply)5 V DC
    24 V DC
    Current Consumption (Internal Power Supply)30 mA / 5 V DC
    30 mA / 24 V DC

    FX5-485ADP

    Transmission StandardsCompliant with the RS-485 and RS-422 standards
    External Device Connection MethodEuropean Terminal Block
    Terminating ResistorBuilt-in (OPEN / 110Ω/ 330Ω)
    InsulationOpto-isolator insulation (between the communication line and the CPU)
    Communication FunctionSimple PC-PC Link FunctionMaximum Total Extension Distance1,200 m or less when the system consists only of FX5-485ADP units
    500 m or less when the system consists of FX5-485ADP and FX3U-485ADP units
    50 m or less in other cases
    Protocol FormatSimple PC to PC link
    Communication MethodBidirectional half-duplex
    Baud Rate38,400 (bps)
    MC Protocol FunctionMaximum Total Extension DistanceFX5-485ADP is used: 1,200 m or less
    Built-in RS-485 port or FX5-485-BD is used: 50 m or less
    Protocol FormatMC protocol (dedicated protocol), 3C/4C frame
    Type 1 / type 4 / type 5 are available.
    Communication MethodBidirectional half-duplex
    Baud Rate300/600/1,200/2,400/4,800/9,600/19,200/38,400/57,600/115,200 (bps)
    Inverter Communication FunctionMaximum Total Extension Distance1,200 m or less
    Protocol FormatInverter computer link
    Control ProcedureAsynchronous
    Communication MethodBidirectional half-duplex
    Baud Rate4,800/9,600/19,200/38,400/57,600/115,200 (bps)
    57,600 (bps) and higher rates are supported only by the FREQROL-A800
    Nonprocedural Communication FunctionMaximum Total Extension Distance1,200 m or less
    Control ProcedureNonprocedural Communication
    Communication MethodBidirectional half-duplex / Bidirectional full-duplex
    Baud Rate300/600/1,200/2,400/4,800/9,600/19,200/38,400/57,600/115,200 (bps)
    Communication Protocol Support FunctionMaximum Total Extension Distance1,200 m or less
    Protocol FormatCommunication Protocol Support
    Communication MethodBidirectional half-duplex
    Baud Rate9,600/19,200/38,400/57,600/115,200 (bps)
    MODBUS Communication FunctionTransmitting Distance1,200 m or less when the system consists only of FX5-485ADP units
    50 m or less in other cases
    Communication ProtocolRTU
    Baud Rate300/600/1,200/2,400/4,800/9,600/19,200/38,400/57,600/115,200 (bps)
    Compatible CPU UnitsFX5U CPU unit: Ver. 1.000 onward (from the first unit)
    FX5UC CPU unit: Ver. 1.010 onward (from the first unit)
    WeightApprox. 80 g
    Power Supply Specifications
    Rated Voltage (Internal Power Supply)5 V DC
    24 V DC
    Current Consumption (Internal Power Supply)20 mA / 5 V DC
    30 mA / 24 V DC
    • *See the catalog for product information other than the listed above.